Volumetric image-guidance: does routine usage prompt adaptive re-planning? An institutional review.

James A Tanyi1, Martin H Fuss.   

Abstract

PURPOSE: To investigate how the use of volumetric image-guidance using an on-board cone-beam computed tomography (CBCT) system impacts on the frequency of adaptive re-planning.
MATERIAL AND METHODS: Treatment courses of 146 patients who have undergone a course of external beam radiation therapy (EBRT) using volumetric CBCT image-guidance were analyzed. Target locations included the brain, head and neck, chest, abdomen, as well as prostate and non-prostate pelvis. The majority of patients (57.5%) were treated with hypo-fractionated treatment regimens (three to 15 fraction courses). The frequency of image-guidance ranged from daily (87.7%) to weekly or twice weekly. The underlying medical necessity for adaptive re-planning as well as frequency and consequences of plan adaptation to dose-volume parameters was assessed.
RESULTS: Radiation plans of 34 patients (23.3%) were adapted at least once (up to six time) during their course of EBRT as a result of image-guidance CBCT review. Most common causes for adaptive planning were: tumor change (mostly shrinkage: 10 patients; four patients more than one re-plan), change in abdominal girth (systematic change in hollow organ filling; n=7, two patients more than one re-plan), weight loss (n=5), and systematic target setup deviation from simulation (n=5). Adaptive re-plan was required mostly for conventionally fractionated courses; only 5 patient plans undergoing hypo-fractionated treatment were adjusted. In over 91% of adapted plans, the dose-volume parameters did deviate from the prescribed plan parameters by more than 5% for at least 10% of the target volume, or organs-at-risk in close proximity to the target volume. DISCUSSION: Routine use of volumetric image-guidance has in our practice increased the demand for adaptive re-planning. Volumetric CBCT image-guidance provides sufficient imaging information to reliably predict the need for dose adjustment. In the vast majority of cases evaluated, the initial and adapted dose-volume parameters differed to a degree that was considered clinically significant.

Entities:  

Mesh:

Year:  2008        PMID: 18661434     DOI: 10.1080/02841860802279741

Source DB:  PubMed          Journal:  Acta Oncol        ISSN: 0284-186X            Impact factor:   4.089


  8 in total

1.  Image-guided radiation therapy: a new era for the radiation oncologist?

Authors:  Filippo Alongi; Nadia Di Muzio
Journal:  Int J Clin Oncol       Date:  2009-12-05       Impact factor: 3.402

2.  Uncertainties encountered in implementation of adaptive planning with in vivo dosimeters.

Authors:  M T Studenski; S J Gardner; R B Den
Journal:  Radiol Phys Technol       Date:  2014-09-19

3.  Clinical evaluation of soft tissue organ boundary visualization on cone-beam computed tomographic imaging.

Authors:  Elisabeth Weiss; Jian Wu; William Sleeman; Joshua Bryant; Priya Mitra; Michael Myers; Tatjana Ivanova; Nitai Mukhopadhyay; Viswanathan Ramakrishnan; Martin Murphy; Jeffrey Williamson
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-06-09       Impact factor: 7.038

4.  Accurate positioning for head and neck cancer patients using 2D and 3D image guidance.

Authors:  Hyejoo Kang; Dale M Lovelock; Ellen D Yorke; Sergey Kriminski; Nancy Lee; Howard I Amols
Journal:  J Appl Clin Med Phys       Date:  2010-10-27       Impact factor: 2.102

5.  Technical advances and pitfalls in head and neck radiotherapy.

Authors:  Upendra Parvathaneni; George E Laramore; Jay J Liao
Journal:  J Oncol       Date:  2012-05-30       Impact factor: 4.375

6.  The frequency of re-planning and its variability dependent on the modification of the re-planning criteria and IGRT correction strategy in head and neck IMRT.

Authors:  Markus Stoll; Kristina Giske; Jürgen Debus; Rolf Bendl; Eva Maria Stoiber
Journal:  Radiat Oncol       Date:  2014-08-11       Impact factor: 3.481

7.  UK adaptive radiotherapy practices for head and neck cancer patients.

Authors:  Victor Shing-Cheung Lee; Giuseppe SchettIno; Andrew Nisbet
Journal:  BJR Open       Date:  2020-12-11

8.  Investigation of the usability of conebeam CT data sets for dose calculation.

Authors:  Anne Richter; Qiaoqiao Hu; Doreen Steglich; Kurt Baier; Jürgen Wilbert; Matthias Guckenberger; Michael Flentje
Journal:  Radiat Oncol       Date:  2008-12-16       Impact factor: 3.481

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.