Literature DB >> 25228066

Comparison of optotypes of Amsterdam Picture Chart with those of Tumbling-E, LEA symbols, ETDRS, and Landolt-C in non-amblyopic and amblyopic patients.

O Engin1, D D G Despriet, H M van der Meulen-Schot, A Romers, X Slot, M Tjon Fo Sang, M Fronius, H Kelderman, H J Simonsz.   

Abstract

PURPOSE: To compare optotypes of the Amsterdam Picture Chart (APK) with those of Landolt-C (LC), Tumbling-E (TE), ETDRS and LEA symbols (LEA), to assess their reliability in measuring visual acuity (VA).
METHODS: We recruited healthy controls with equal VA and amblyopes with ≥2 LogMAR lines interocular difference. New logarithmic charts were developed with LC, TE, ETDRS, LEA, and APK with identical size and spacing (four optotypes) between optotypes. Charts were randomly presented at 5 m under DIN EN ISO 8596 and 8597 conditions. VA was measured with LC (LC-VA), TE, ETDRS, LEA, and APK, using six out of ten optotypes answered correctly as threshold.
RESULTS: In 100 controls aged 17-31, LC-VA was -0.207 ± SD 0.089 LogMAR. Visual acuity measured with TE differed from LC-VA by 0.021 (positive value meaning less recognizable), with ETDRS 0.012, with Lea 0.054, and with APK 0.117. In 46 amblyopic eyes with LC-VA <0.5 LogMAR, the difference was for TE 0.017, for ETDRS 0.017, for LEA 0.089, and for APK 0.213. In 13 amblyopic eyes with LC-VA ≥0.5 LogMAR, the difference was for TE 0.122, ETDRS 0.047, LEA 0.057, and APK 0.019. APK optotypes had a lower percentage of passed subjects at each LogMAR line compared to Landolt-C. The 11 APK optotypes had different thresholds.
CONCLUSIONS: Small APK optotypes were recognized worse than all other optotypes, probably because of their thinner lines. Large APK optotypes were recognized relatively well, possibly reflecting recognition acuity. Differences between the thresholds of the 11 APK optotypes reduced its sensitivity further.

Entities:  

Mesh:

Year:  2014        PMID: 25228066     DOI: 10.1007/s00417-014-2763-7

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  10 in total

1.  [Correlation of letter optotypes with Landholt ring for different degrees of visual acuity].

Authors:  B Rassow; Y Wang
Journal:  Klin Monbl Augenheilkd       Date:  1999-08       Impact factor: 0.700

2.  Examination of young children with Lea symbols.

Authors:  R Becker; S Hübsch; M H Gräf; H Kaufmann
Journal:  Br J Ophthalmol       Date:  2002-05       Impact factor: 4.638

3.  [New DIN norms for determination of visual acuity].

Authors:  W Wesemann; U Schiefer; M Bach
Journal:  Ophthalmologe       Date:  2010-09       Impact factor: 1.059

4.  Differences between recognition and resolution acuity in patients undergoing macular hole surgery.

Authors:  Walter Wittich; Olga Overbury; Michael A Kapusta; Donald H Watanabe
Journal:  Invest Ophthalmol Vis Sci       Date:  2006-08       Impact factor: 4.799

5.  Adult discrimination performance for pediatric acuity test optotypes.

Authors:  T Rowan Candy; Sylvia R Mishoulam; Robert M Nosofsky; Velma Dobson
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-06-16       Impact factor: 4.799

6.  New visual acuity test for pre-school children.

Authors:  L Hyvärinen; R Näsänen; P Laurinen
Journal:  Acta Ophthalmol (Copenh)       Date:  1980-08

7.  Lea symbols: visual acuity assessment and detection of amblyopia.

Authors:  M H Gräf; R Becker; H Kaufmann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2000-01       Impact factor: 3.117

8.  [Determining visual acuity with LH symbols and Landolt rings].

Authors:  M Gräf; R Becker
Journal:  Klin Monbl Augenheilkd       Date:  1999-08       Impact factor: 0.700

9.  Development of visual acuity in preschool children as measured with Landolt C and Tumbling E charts.

Authors:  Yu-Hung Lai; Hwei-Zu Wang; Hsin-Tien Hsu
Journal:  J AAPOS       Date:  2011-06       Impact factor: 1.220

10.  [Comparison of visual acuity measured using Landolt-C and ETDRS charts in healthy subjects and patients with various eye diseases].

Authors:  R Becker; G Teichler; M Gräf
Journal:  Klin Monbl Augenheilkd       Date:  2011-10-13       Impact factor: 0.700

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.