Literature DB >> 25212797

Pressure fields by flow-sensitive, 4D, velocity-encoded CMR in patients with aortic coarctation.

Eugénie Riesenkampff1, Joao Filipe Fernandes2, Sebastian Meier3, Leonid Goubergrits4, Siegfried Kropf5, Stephan Schubert1, Felix Berger1, Anja Hennemuth3, Anja Henneumuth3, Titus Kuehne6.   

Abstract

This study compared pressure fields by 4-dimensional (4D), velocity-encoded cine (VEC) cardiac magnetic resonance imaging (CMR) with pressures measured by the clinical gold standard catheterization. Thirteen patients (n = 7 male, n = 6 female) with coarctation were studied. The 4D-VEC-CMR pressure fields were computed by solving the Pressure-Poisson equation. The agreement between catheterization and CMR-based methods was determined at 5 different measurement sites along the aorta. For all sites, the correlation coefficients between measures varied between 0.86 and 0.97 (p < 0.001). The Bland-Altman test showed good agreement between peak systolic pressure gradients across the coarctation. The nonsignificant (p > 0.2) bias was +2.3 mm Hg (± 6.4 mm Hg, 2 SDs) for calibration with dynamic pressures and +1.5 mm Hg (± 4.6 mm Hg, 2 SDs) for calibration with static pressure. In a clinical setting of coarctation, pressure fields can be accurately computed from 4D-VEC-CMR-derived flows. In patients with coarctation, this noninvasive technique might evolve to an alternative to invasive catheterization.
Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  cardiac magnetic resonance; catheterization; coarctation; pressure

Mesh:

Substances:

Year:  2014        PMID: 25212797     DOI: 10.1016/j.jcmg.2014.03.017

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


  13 in total

1.  Reproducibility and interobserver variability of systolic blood flow velocity and 3D wall shear stress derived from 4D flow MRI in the healthy aorta.

Authors:  Pim van Ooij; Alexander L Powell; Wouter V Potters; James C Carr; Michael Markl; Alex J Barker
Journal:  J Magn Reson Imaging       Date:  2015-07-03       Impact factor: 4.813

Review 2.  Clinical Applications of MRA 4D-Flow.

Authors:  Lilia M Sierra-Galan; Christopher J François
Journal:  Curr Treat Options Cardiovasc Med       Date:  2019-09-10

3.  Impact of different coarctation therapies on aortic stiffness: phase-contrast MRI study.

Authors:  Michal Schäfer; Gareth J Morgan; Max B Mitchell; Michael Ross; Alex J Barker; Kendall S Hunter; Brian Fonseca; Michael DiMaria; Daniel Vargas; D Dunbar Ivy; Neil Wilson; Lorna P Browne
Journal:  Int J Cardiovasc Imaging       Date:  2018-04-17       Impact factor: 2.357

Review 4.  Society for Cardiovascular Magnetic Resonance/European Society of Cardiovascular Imaging/American Society of Echocardiography/Society for Pediatric Radiology/North American Society for Cardiovascular Imaging Guidelines for the Use of Cardiac Magnetic Resonance in Pediatric Congenital and Acquired Heart Disease: Endorsed by The American Heart Association.

Authors:  Mark A Fogel; Shaftkat Anwar; Craig Broberg; Lorna Browne; Taylor Chung; Tiffanie Johnson; Vivek Muthurangu; Michael Taylor; Emanuela Valsangiacomo-Buechel; Carolyn Wilhelm
Journal:  Circ Cardiovasc Imaging       Date:  2022-06-21       Impact factor: 8.589

Review 5.  Society for Cardiovascular Magnetic Resonance/European Society of Cardiovascular Imaging/American Society of Echocardiography/Society for Pediatric Radiology/North American Society for Cardiovascular Imaging Guidelines for the use of cardiovascular magnetic resonance in pediatric congenital and acquired heart disease : Endorsed by The American Heart Association.

Authors:  Mark A Fogel; Shaftkat Anwar; Craig Broberg; Lorna Browne; Taylor Chung; Tiffanie Johnson; Vivek Muthurangu; Michael Taylor; Emanuela Valsangiacomo-Buechel; Carolyn Wilhelm
Journal:  J Cardiovasc Magn Reson       Date:  2022-06-21       Impact factor: 6.903

Review 6.  Noninvasive Imaging of Flow and Vascular Function in Disease of the Aorta.

Authors:  Matthew C Whitlock; W Gregory Hundley
Journal:  JACC Cardiovasc Imaging       Date:  2015-09

Review 7.  4D flow MRI applications in congenital heart disease.

Authors:  Judy Rizk
Journal:  Eur Radiol       Date:  2020-09-01       Impact factor: 5.315

Review 8.  Advanced flow MRI: emerging techniques and applications.

Authors:  M Markl; S Schnell; C Wu; E Bollache; K Jarvis; A J Barker; J D Robinson; C K Rigsby
Journal:  Clin Radiol       Date:  2016-03-02       Impact factor: 2.350

9.  Four-dimensional Flow Magnetic Resonance Imaging Quantification of Blood Flow in Bicuspid Aortic Valve.

Authors:  Daniel Z Gordon; Muhannad A Abbasi; Jeesoo Lee; Roberto Sarnari; Alireza Sojoudi; Qiao Wei; Michael B Scott; Jeremy D Collins; Bradley D Allen; Julie A Blaisdell; James C Carr; Michael Markl
Journal:  J Thorac Imaging       Date:  2020-11-01       Impact factor: 5.528

10.  Non-invasive pressure difference estimation from PC-MRI using the work-energy equation.

Authors:  Fabrizio Donati; C Alberto Figueroa; Nicolas P Smith; Pablo Lamata; David A Nordsletten
Journal:  Med Image Anal       Date:  2015-09-08       Impact factor: 8.545

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.