Cell streak imaging cytometry for rare cell detection.

Joshua Balsam1, Hugh Alan Bruck2, Avraham Rasooly3.   

Abstract

Detection of rare cells, such as circulating tumor cells, have many clinical applications. To measure rare cells with increased sensitivity and improved data managements, we developed an imaging flow cytometer with a streak imaging mode capability. The new streak mode imaging mode utilizes low speed video to capture moving fluorescently labeled cells in a flow cell. Each moving cell is imaged on multiple pixels on each frame, where the cell path is marked as a streak line proportional to the length of the exposure. Finding rare cells (e.g., <1 cell/mL) requires measuring larger sample volumes to achieve higher sensitivity, therefore we combined streak mode imaging with a "wide" high throughput flow cell (e.g. flow rates set to 10 mL/min) in contrast to the conventional "narrow" hydrodynamic focusing cells typically used in cytometry that are inherently limited to low flow rates. The new flow cell is capable of analyzing 20 mL/min of fluorescently labeled cells. To further increase sensitivity, the signal to noise ratio of the images was also enhanced by combining three imaging methods: (1) background subtraction, (2) pixel binning, and (3) CMOS color channel selection. The streaking mode cytometer has been used for the analysis of SYTO-9 labeled THP-1 human monocytes in buffer and in blood. Samples of cells at 1 cell/mL and 0.1 cell/mL were analyzed in 30 mL with flow rates set to 10 mL/min and frame rates of 4 fps (frame per second). For the target of 1 cell/mL, an average concentration of 0.91 cell/mL was measured by cytometry, with a standard error of 0.03 (C(95) = 0.85-0.97). For the target of 0.1 cell/mL, an average concentration of 0.083 cell/mL was measured, with a standard error of 0.01 (C(95) = 0.065-0.102). Whole blood was also spiked with SYTO-9 labeled cells to a concentration of 10 cell/mL, and the average flow cytometry measurement was 8.7 cells/mL (i.e. 0.87 cells/mL in diluted blood) with a 95% CL of 8.1-9.2 cells/mL. This demonstrated the ability to detect rare cells in blood with high accuracy. Such detection approaches for rare cells have many potential clinical applications. Furthermore, the simplicity and low cost of this device may enable expansion of cell-based clinical diagnostics, especially in resource-poor settings. Published by Elsevier B.V.

Entities:  

Keywords:  Flow cytometry; Image enhancement; Rare cells; Resource-poor settings; Wide-field imaging; mHealth

Mesh:

Year:  2014        PMID: 25212069      PMCID: PMC4252841          DOI: 10.1016/j.bios.2014.08.065

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  10 in total

Review 1.  Evanescent wave fluorescence biosensors.

Authors:  Chris Rowe Taitt; George P Anderson; Frances S Ligler
Journal:  Biosens Bioelectron       Date:  2004-12-08       Impact factor: 10.618

2.  Multiplexed measurement of serum antibodies using an array biosensor.

Authors:  Maria C Moreno-Bondi; Chris Rowe Taitt; Lisa C Shriver-Lake; Frances S Ligler
Journal:  Biosens Bioelectron       Date:  2006-01-24       Impact factor: 10.618

Review 3.  The array biosensor: portable, automated systems.

Authors:  Frances S Ligler; Kim E Sapsford; Joel P Golden; Lisa C Shriver-Lake; Chris R Taitt; Maureen A Dyer; Salvatore Barone; Christopher J Myatt
Journal:  Anal Sci       Date:  2007-01       Impact factor: 2.081

4.  A fluorescence detection platform using spatial electroluminescent excitation for measuring botulinum neurotoxin A activity.

Authors:  Kim E Sapsford; Steven Sun; Jesse Francis; Shashi Sharma; Yordan Kostov; Avraham Rasooly
Journal:  Biosens Bioelectron       Date:  2008-06-18       Impact factor: 10.618

5.  A simple portable electroluminescence illumination-based CCD detector.

Authors:  Yordan Kostov; Nikolay Sergeev; Sean Wilson; Keith E Herold; Avraham Rasooly
Journal:  Methods Mol Biol       Date:  2009

Review 6.  Analytical capabilities of the ImageStream cytometer.

Authors:  Ewa K Zuba-Surma; Mariusz Z Ratajczak
Journal:  Methods Cell Biol       Date:  2011       Impact factor: 1.441

7.  Webcam-based flow cytometer using wide-field imaging for low cell number detection at high throughput.

Authors:  Joshua Balsam; Hugh Alan Bruck; Avraham Rasooly
Journal:  Analyst       Date:  2014-09-07       Impact factor: 4.616

8.  Detection of deoxynivalenol in foods and indoor air using an array biosensor.

Authors:  Miriam M Ngundi; Syed A Qadri; Elizabeth V Wallace; Martin H Moore; Michael E Lassman; Lisa C Shriver-Lake; Frances S Ligler; Chris R Taitt
Journal:  Environ Sci Technol       Date:  2006-04-01       Impact factor: 9.028

9.  Multi-wavelength Spatial LED illumination based detector for in vitro detection of Botulinum Neurotoxin A Activity.

Authors:  Steven Sun; Jesse Francis; Kim E Sapsford; Yordan Kostov; Avraham Rasooly
Journal:  Sens Actuators B Chem       Date:  2010-04-08       Impact factor: 7.460

10.  Optofluidic fluorescent imaging cytometry on a cell phone.

Authors:  Hongying Zhu; Sam Mavandadi; Ahmet F Coskun; Oguzhan Yaglidere; Aydogan Ozcan
Journal:  Anal Chem       Date:  2011-08-02       Impact factor: 6.986

  10 in total
  3 in total

Review 1.  Engineering opportunities in cancer immunotherapy.

Authors:  Laura Jeanbart; Melody A Swartz
Journal:  Proc Natl Acad Sci U S A       Date:  2015-11-24       Impact factor: 11.205

2.  Computational cytometer based on magnetically modulated coherent imaging and deep learning.

Authors:  Yibo Zhang; Mengxing Ouyang; Aniruddha Ray; Tairan Liu; Janay Kong; Bijie Bai; Donghyuk Kim; Alexander Guziak; Yi Luo; Alborz Feizi; Katherine Tsai; Zhuoran Duan; Xuewei Liu; Danny Kim; Chloe Cheung; Sener Yalcin; Hatice Ceylan Koydemir; Omai B Garner; Dino Di Carlo; Aydogan Ozcan
Journal:  Light Sci Appl       Date:  2019-10-02       Impact factor: 17.782

Review 3.  Improving the Sensitivity and Functionality of Mobile Webcam-Based Fluorescence Detectors for Point-of-Care Diagnostics in Global Health.

Authors:  Reuven Rasooly; Hugh Alan Bruck; Joshua Balsam; Ben Prickril; Miguel Ossandon; Avraham Rasooly
Journal:  Diagnostics (Basel)       Date:  2016-05-17
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.