Literature DB >> 19151946

A simple portable electroluminescence illumination-based CCD detector.

Yordan Kostov1, Nikolay Sergeev, Sean Wilson, Keith E Herold, Avraham Rasooly.   

Abstract

In this chapter we describe a simple and relatively inexpensive Electroluminescence (EL) illumination and charged-coupled device (CCD) camera (EL-CCD) based detector for monitoring fluorescence and colorimetric assays. The portable battery-operated fluorescence detector includes an EL panel for fluoro-genic excitation at 490 nm, a cooled CCD digital camera to monitor emission at 523 nm, filters and a close up lens. The detector system is controlled by a laptop computer for camera operation, image acquisition and analysis. The system was tested using a fluorogenic peptide substrate (SNAP-25) for botulinum neurotoxin serotype A (BoNT-A) labeled with FITC. The level of detection of the system was found to be 1.25 nM of the peptide, similar to the detection level of a commercial photomultipler-based plate fluorometer. The multichannel EL-CCD was used with an assay plate capable of testing nine samples simultaneously in 1 min at this detection level. The portable system is small and is operated by a 12 V source. The modular detector was designed with easily interchangeable ELs, filters and lenses and can be used and adapted for a wide variety of fluorescence and colorimetric assays, fluorescence labels and assay formats.

Entities:  

Mesh:

Year:  2009        PMID: 19151946     DOI: 10.1007/978-1-60327-567-5_14

Source DB:  PubMed          Journal:  Methods Mol Biol        ISSN: 1064-3745


  4 in total

1.  Cell streak imaging cytometry for rare cell detection.

Authors:  Joshua Balsam; Hugh Alan Bruck; Avraham Rasooly
Journal:  Biosens Bioelectron       Date:  2014-09-01       Impact factor: 10.618

2.  Capillary Array Waveguide Amplified Fluorescence Detector for mHealth.

Authors:  Joshua Balsam; Hugh Alan Bruck; Avraham Rasooly
Journal:  Sens Actuators B Chem       Date:  2013-09       Impact factor: 7.460

3.  Sensing the deadliest toxin: technologies for botulinum neurotoxin detection.

Authors:  Petr Capek; Tobin J Dickerson
Journal:  Toxins (Basel)       Date:  2010-01-07       Impact factor: 4.546

Review 4.  Improving the Sensitivity and Functionality of Mobile Webcam-Based Fluorescence Detectors for Point-of-Care Diagnostics in Global Health.

Authors:  Reuven Rasooly; Hugh Alan Bruck; Joshua Balsam; Ben Prickril; Miguel Ossandon; Avraham Rasooly
Journal:  Diagnostics (Basel)       Date:  2016-05-17
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.