Literature DB >> 14586855

Factors influencing the resonance frequency of dental implants.

Haw-Ming Huang1, Ching-Lai Chiu, Ching-Ying Yeh, Sheng-Yang Lee.   

Abstract

PURPOSE: Resonance frequency (RF) analysis has been used by several investigators to assess the boundary conditions of dental implants. However, a scientific investigation of the association between the structural condition of the alveolar bone and the dynamic behavior of dental implants has not yet been reported. The aim of this study was to assess the factors influencing the RF of dental implants using an in vitro modal analysis.
MATERIALS AND METHODS: Resonant vibration within implants was induced by an impulse-force hammer. The induced vibration signal was subsequently detected using an acoustic microphone and analyzed by fast Fourier transform. The resultant data were further analyzed to test the statistical effects of the embedding-material boundary height, thickness, and density on the RF values of the sample implants.
RESULTS: Significant changes (P <.05) in RF values were revealed for implants embedded within a high-density block when decreasing boundary height reached 6, 5, and 4 mm, at respective thickness increments of 10, 15, and 20 mm. For analogous low-density samples, significant changes (P <.05) in RF values were found when respective decreasing boundary height reached 6, 4, and 3 mm.
CONCLUSIONS: Our findings indicate that boundary height, width, and density factors can influence the RF of dental implants and that a lower boundary density and greater boundary thickness can lead to more obvious RF changes.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14586855     DOI: 10.1016/s0278-2391(03)00680-3

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  11 in total

1.  Non-destructive natural frequency tests of cyclic fatigue-loaded nickel-titanium rotary instruments.

Authors:  Sung-Chih Hsieh; Sheng-Yang Lee; Chun-Yu Ciou; Haw-Ming Huang
Journal:  Med Biol Eng Comput       Date:  2010-06       Impact factor: 2.602

2.  Clinical study on the primary stability of two dental implant systems with resonance frequency analysis.

Authors:  Annette Rabel; Steffen Gerhard Köhler; Andrea Maria Schmidt-Westhausen
Journal:  Clin Oral Investig       Date:  2007-03-31       Impact factor: 3.573

3.  Template-guided vs. non-guided drilling in site preparation of dental implants.

Authors:  Uta Scherer; Marcus Stoetzer; Martin Ruecker; Nils-Claudius Gellrich; Constantin von See
Journal:  Clin Oral Investig       Date:  2014-10-30       Impact factor: 3.573

4.  Structural stability of posterior retainer design for resin-bonded prostheses: a 3D finite element study.

Authors:  Jie Lin; Zhiqiang Zheng; Akikazu Shinya; Jukka Pekka Matinlinna; Michael George Botelho; Akiyoshi Shinya
Journal:  Odontology       Date:  2014-09-09       Impact factor: 2.634

5.  Transformation of vibration signals in rotary blood pumps: the diagnostic potential of pump failure.

Authors:  Koji Kawahito
Journal:  J Artif Organs       Date:  2013-04-27       Impact factor: 1.731

6.  A comparison of the implant stability among various implant systems: clinical study.

Authors:  Jae-Min Kim; Sun-Jong Kim; Inho Han; Sang-Wan Shin; Jae-Jun Ryu
Journal:  J Adv Prosthodont       Date:  2009-03-31       Impact factor: 1.904

7.  A Radiographic and Clinical Comparison of Immediate vs. Early Loading (4 Weeks) of Implants with a New Thermo-Chemically Treated Surface: A Randomized Clinical Trial.

Authors:  Matteo Albertini; Federico Herrero-Climent; Carmen María Díaz-Castro; Jose Nart; Ana Fernández-Palacín; José Vicente Ríos-Santos; Mariano Herrero-Climent
Journal:  Int J Environ Res Public Health       Date:  2021-01-29       Impact factor: 3.390

8.  Effects of continual intermittent administration of parathyroid hormone on implant stability in the presence of osteoporosis: an in vivo study using resonance frequency analysis in a rabbit model.

Authors:  Yoshifumi Oki; Kazuya Doi; Yusuke Makihara; Reiko Kobatake; Takayasu Kubo; Kazuhiro Tsuga
Journal:  J Appl Oral Sci       Date:  2017 Sep-Oct       Impact factor: 2.698

9.  Experimental Investigation of Vibration Analysis on Implant Stability for a Novel Implant Design.

Authors:  Shouxun Lu; Benjamin Steven Vien; Matthias Russ; Mark Fitzgerald; Wing Kong Chiu
Journal:  Sensors (Basel)       Date:  2022-02-21       Impact factor: 3.576

10.  ISQ calculation evaluation of in vitro laser scanning vibrometry-captured resonance frequency.

Authors:  Stijn Debruyne; Nicolas Grognard; Gino Verleye; Korneel Van Massenhove; Dimitrios Mavreas; Bart Vande Vannet
Journal:  Int J Implant Dent       Date:  2017-10-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.