Literature DB >> 16803807

A retrospective clinical evaluation of two-unit cantilevered resin-bonded fixed partial dentures.

Michael G Botelho, Katherine C M Leung, Hyden Ng, Kingsley Chan.   

Abstract

BACKGROUND: The authors conducted a study to examine the clinical performance of two-unit cantilevered resin-bonded fixed partial dentures (RBFPDs) that were inserted at The Prince Philip Dental Hospital, University of Hong Kong.
METHODS: The authors recalled patients who had received two-unit cantilevered RBFPDs at least 24 months before the recall examination. The authors recorded the following data: patient's sex and age, operator's experience, prosthesis cementation date, endodontic treatment if performed, bone support, tooth mobility, the presence of shim-stock contacts on the abutment or pontic in intercuspal position, and the presence of aproximal axial contacts adjacent to the prosthesis. They also recorded the date of any debonding with subsequent treatment. They asked the patients qualitative questions about their prostheses.
RESULTS: A total of 269 prostheses were placed in 214 patients and had a mean service life of 51.7 months +/- 19.5 months standard deviation, with a range of 13.2 to 141.6 months. Of 14 failed prostheses, 12 debonded, resulting in a success rate of 94.8 percent and clinical retention rate of 95.5 percent. No discernable rotation or drifting of the abutments was apparent in any of the prostheses. Overall patient satisfaction with RBFPDs was good, with an average assessment score of 8.5.
CONCLUSIONS: The authors observed a 95.5 percent clinical retention rate of 269 two-unit RBFPDs, with no apparent drifting of the abutments. Longer-term follow-up studies are required. CLINICAL IMPLICATIONS: Two-unit RBFPDs are conservative and clinically retentive prostheses in the short to medium term.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16803807     DOI: 10.14219/jada.archive.2006.0290

Source DB:  PubMed          Journal:  J Am Dent Assoc        ISSN: 0002-8177            Impact factor:   3.634


  5 in total

1.  Attitude and awareness of dentist towards resin bonded bridges in Saudi Arabia.

Authors:  Fahim Ahmed Vohra; Muhammed Ayedh Al-Qahtani
Journal:  Saudi Dent J       Date:  2014-05-05

2.  Structural stability of posterior retainer design for resin-bonded prostheses: a 3D finite element study.

Authors:  Jie Lin; Zhiqiang Zheng; Akikazu Shinya; Jukka Pekka Matinlinna; Michael George Botelho; Akiyoshi Shinya
Journal:  Odontology       Date:  2014-09-09       Impact factor: 2.634

3.  In vitro assessment of single-retainer tooth-colored adhesively fixed partial dentures for posterior teeth.

Authors:  Tissiana Bortolotto; Carlo Monaco; Ioana Onisor; Ivo Krejci
Journal:  Int J Dent       Date:  2010-06-21

4.  Fracture characteristics of anterior resin-bonded zirconia-fixed partial dentures.

Authors:  Martin Rosentritt; Stefan Ries; Carola Kolbeck; Maria Westphal; Ernst-Jürgen Richter; Gerhard Handel
Journal:  Clin Oral Investig       Date:  2009-02-17       Impact factor: 3.573

5.  Three-dimensional finite element analysis of anterior two-unit cantilever resin-bonded fixed dental prostheses.

Authors:  Filip Keulemans; Akikazu Shinya; Lippo V J Lassila; Pekka K Vallittu; Cornelis J Kleverlaan; Albert J Feilzer; Roeland J G De Moor
Journal:  ScientificWorldJournal       Date:  2015-03-24
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.