Literature DB >> 25194156

Evaluation of a brachial cuff and suprasystolic waveform algorithm method to noninvasively derive central blood pressure.

Benedict T Costello1, Martin G Schultz2, J Andrew Black1, James E Sharman3.   

Abstract

BACKGROUND: Central blood pressure (BP) can be estimated noninvasively by analyzing brachial artery waveforms. In this study, our aim was to assess the validity of a brachial cuff-based (suprasystolic) technique for estimating central BP (CBPestimated) by comparison with invasive aortic BP (CBPinvasive).
METHODS: Eighty-four simultaneous CBPestimated (Pulsecor R7.0) and CBPinvasive measures were recorded in 47 patients (aged 63±10 years, 62% male) undergoing coronary angiography. Measures were captured at baseline and acutely following intravenous glyceryl trinitrate (GTN; 100-200 μg). Mean CBPinvasive systolic BP (SBP) and diastolic BP (DBP) were compared with CBPestimated SBP and DBP calibrated with brachial SBP and DBP recorded from the Pulsecor device. To test validity of the central BP algorithm, measures of CBPestimated SBP were also compared with CBPinvasive SBP following recalibration with invasive mean arterial pressure (MAP) and DBP.
RESULTS: At baseline, mean difference ± standard deviation between CBPestimated SBP and CBPinvasive SBP was -7±9mm Hg (intraclass correlation coefficient (ICC) = 0.86; P < 0.001) with similar underestimation post-GTN (-6±9mm Hg; ICC = 0.90; P < 0.001). Recalibration of CBPestimated SBP with invasive MAP and DBP resulted in closer mean difference to CBPinvasive SBP (-2±7mm Hg; ICC = 0.95; P < 0.001) at baseline but not post-GTN (-6±7mm Hg; ICC = 0.95; P < 0.001).
CONCLUSIONS: The Pulsecor algorithm to derive central BP has acceptable validity when calibrated with invasive pressures. However, accuracy is compromised when noninvasive brachial cuff BP calibration is used. © American Journal of Hypertension, Ltd 2014. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Keywords:  blood pressure; central blood pressure; hypertension; monitoring; oscillometric; suprasystolic; validation.

Mesh:

Substances:

Year:  2014        PMID: 25194156     DOI: 10.1093/ajh/hpu163

Source DB:  PubMed          Journal:  Am J Hypertens        ISSN: 0895-7061            Impact factor:   2.689


  6 in total

1.  The effect of high altitude on central blood pressure and arterial stiffness.

Authors:  C J Boos; E Vincent; A Mellor; D R Woods; C New; R Cruttenden; M Barlow; M Cooke; K Deighton; P Scott; S Clarke; J O'Hara
Journal:  J Hum Hypertens       Date:  2017-05-25       Impact factor: 3.012

2.  Central blood pressure assessment using oscillometry is feasible for everyday clinical practice.

Authors:  A Reshetnik; C Gohlisch; W Zidek; M Tölle; M van der Giet
Journal:  J Hum Hypertens       Date:  2016-04-28       Impact factor: 3.012

3.  Estimation of coronary wave intensity analysis using noninvasive techniques and its application to exercise physiology.

Authors:  Christopher J Broyd; Sukhjinder Nijjer; Sayan Sen; Ricardo Petraco; Siana Jones; Rasha Al-Lamee; Nicolas Foin; Mahmud Al-Bustami; Amarjit Sethi; Raffi Kaprielian; Punit Ramrakha; Masood Khan; Iqbal S Malik; Darrel P Francis; Kim Parker; Alun D Hughes; Ghada W Mikhail; Jamil Mayet; Justin E Davies
Journal:  Am J Physiol Heart Circ Physiol       Date:  2015-12-18       Impact factor: 4.733

4.  Central Systolic Hypertension in Patients with Well-Controlled Hypertension.

Authors:  Jozef Bulas; Mária Potočárová; Ján Murín; Katarína Kozlíková; Ján Luha; Martin Čaprnda
Journal:  Biomed Res Int       Date:  2017-01-03       Impact factor: 3.411

5.  Cardiovascular Remodeling Experienced by Real-World, Unsupervised, Young Novice Marathon Runners.

Authors:  Andrew D'Silva; Anish N Bhuva; Jet van Zalen; Rachel Bastiaenen; Amna Abdel-Gadir; Siana Jones; Niromila Nadarajan; Katia D Menacho Medina; Yang Ye; Joao Augusto; Thomas A Treibel; Stefania Rosmini; Manish Ramlall; Paul R Scully; Camilla Torlasco; James Willis; Gherardo Finocchiaro; Efstathios Papatheodorou; Harshil Dhutia; Della Cole; Irina Chis Ster; Alun D Hughes; Rajan Sharma; Charlotte Manisty; Guy Lloyd; James C Moon; Sanjay Sharma
Journal:  Front Physiol       Date:  2020-03-18       Impact factor: 4.566

6.  Transfer-function-free technique for the noninvasive determination of the human arterial pressure waveform.

Authors:  Alessandro Giudici; Carlo Palombo; Carmela Morizzo; Michaela Kozakova; J Kennedy Cruickshank; Ian B Wilkinson; Ashraf W Khir
Journal:  Physiol Rep       Date:  2021-09
  6 in total