Literature DB >> 31916068

Impact of aortic valve calcification severity on device success after transcatheter aortic valve replacement.

Jeremy Larroche1,2, Loïc Panh3, Thibault Lhermusier1,4,2, Vincent Bataille1, Marie-Agnès Marachet5,6, Thomas Chollet1,4,2, Antoine Petermann3, Frederic Bouisset1,2, Nicolas Boudou7, Bertrand Marcheix8,9,2, Hervé Rousseau5,8,6, Michel Galinier1,8, Didier Carrié1,5,4, Olivier Lairez1,5,8,2, Yoan Lavie-Badie10,11,12,13.   

Abstract

Aortic valvular calcium score (AVCS) can identify severe aortic stenosis (AS) and provide powerful prognostic information. In severe and symptomatic AS, patients can be referred for a transcatheter aortic valve replacement (TAVR). The aim of this study was to determine whether AVCS, measured on the preoperative contrast enhanced multislice computed tomography (MSCT), is associated with device success (DS), major adverse cardiac events (MACEs) and paravalvular leak (PVL) after TAVR. Three hundred and fifty-two consecutive patients who underwent TAVR with a preoperative standardised contrast enhanced MSCT were included in the study. Valvular calcification detection was defined by adding + 100 Hounsfield Unit (HU) to mean HU determined by a region of interest placed in the contrast enhanced ascending aorta. AVCS was then indexed to the aortic annulus surface (AVCSi). Endpoints were DS and 30-day MACE according to Valve Academic Research Consortium-2 consensus document, and moderate to severe PVL. DS was obtained for 305 patients. In multivariate analysis, AVCSi was negatively and independently associated with DS: OR = 0.99, 95% CI 0.99-0.99, p = 0.03. In the subgroup analysis, this association was particularly relevant with self-expanding prostheses [n = 151 (43%), p = 0.018] and in the cases of asymmetric calcium valvular distribution [n = 283 (80%), p 0.002]. There was no association between MACE and AVCS (p = 0.953) and AVCSi (p = 0.757). PVL was positively associated with AVCS (p < 0.001) and AVCSi (p < 0.001). In conclusion, in TAVR, AVCS, measured on preoperative contrast enhanced MSCT, is significantly associated with DS and PVL, but not with 30-day MACE. Its routine use could be relevant to appreciate success chances of TAVR.

Entities:  

Keywords:  Aortic valve disease; CT scanning; Calcium scoring; Paravalvular leak; TAVR

Mesh:

Year:  2020        PMID: 31916068     DOI: 10.1007/s10554-019-01759-7

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  23 in total

1.  EuroSCORE II.

Authors:  Samer A M Nashef; François Roques; Linda D Sharples; Johan Nilsson; Christopher Smith; Antony R Goldstone; Ulf Lockowandt
Journal:  Eur J Cardiothorac Surg       Date:  2012-02-29       Impact factor: 4.191

2.  Prognostic Impact of Calcium Score after Transcatheter Aortic Valve Implantation Performed With New Generation Prosthesis.

Authors:  Mariama Akodad; Benoit Lattuca; Audrey Agullo; Jean-Christophe Macia; Thomas Gandet; Grégory Marin; Anaïs Iemmi; Hélène Vernhet; Laurent Schmutz; Nicolas Nagot; Bernard Albat; Guillaume Cayla; Florence Leclercq
Journal:  Am J Cardiol       Date:  2018-02-12       Impact factor: 2.778

3.  Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients.

Authors:  Jeffrey J Popma; G Michael Deeb; Steven J Yakubov; Mubashir Mumtaz; Hemal Gada; Daniel O'Hair; Tanvir Bajwa; John C Heiser; William Merhi; Neal S Kleiman; Judah Askew; Paul Sorajja; Joshua Rovin; Stanley J Chetcuti; David H Adams; Paul S Teirstein; George L Zorn; John K Forrest; Didier Tchétché; Jon Resar; Antony Walton; Nicolo Piazza; Basel Ramlawi; Newell Robinson; George Petrossian; Thomas G Gleason; Jae K Oh; Michael J Boulware; Hongyan Qiao; Andrew S Mugglin; Michael J Reardon
Journal:  N Engl J Med       Date:  2019-03-16       Impact factor: 91.245

4.  Two-year outcomes after transcatheter or surgical aortic-valve replacement.

Authors:  Susheel K Kodali; Mathew R Williams; Craig R Smith; Lars G Svensson; John G Webb; Raj R Makkar; Gregory P Fontana; Todd M Dewey; Vinod H Thourani; Augusto D Pichard; Michael Fischbein; Wilson Y Szeto; Scott Lim; Kevin L Greason; Paul S Teirstein; S Chris Malaisrie; Pamela S Douglas; Rebecca T Hahn; Brian Whisenant; Alan Zajarias; Duolao Wang; Jodi J Akin; William N Anderson; Martin B Leon
Journal:  N Engl J Med       Date:  2012-03-26       Impact factor: 91.245

5.  Transcatheter aortic-valve replacement with a self-expanding prosthesis.

Authors:  David H Adams; Jeffrey J Popma; Michael J Reardon
Journal:  N Engl J Med       Date:  2014-09-04       Impact factor: 91.245

6.  High Agatston aortic valve calcium score predicts transcatheter paravalvular aortic regurgitation.

Authors:  Kevin L Greason; Eric E Williamson; Rakesh M Suri; Verg Mathew
Journal:  J Thorac Cardiovasc Surg       Date:  2014-02-20       Impact factor: 5.209

7.  A revised methodology for aortic-valvar complex calcium quantification for transcatheter aortic valve implantation.

Authors:  Hasan Jilaihawi; Raj R Makkar; Mohammad Kashif; Kazuaki Okuyama; Tarun Chakravarty; Takahiro Shiota; Gerald Friede; Mamoo Nakamura; Niraj Doctor; Asim Rafique; Kentaro Shibayama; Hirotsugu Mihara; Alfredo Trento; Wen Cheng; John Friedman; Daniel Berman; Gregory P Fontana
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2014-09-03       Impact factor: 6.875

8.  Quantifying Aortic Valve Calcification using Coronary Computed Tomography Angiography.

Authors:  Abdulrahman M Alqahtani; Kevin E Boczar; Vinay Kansal; Kwan Chan; Girish Dwivedi; Benjamin J W Chow
Journal:  J Cardiovasc Comput Tomogr       Date:  2017-01-30

9.  Computed Tomography Aortic Valve Calcium Scoring in Patients With Aortic Stenosis.

Authors:  Tania Pawade; Marie-Annick Clavel; Christophe Tribouilloy; Julien Dreyfus; Tiffany Mathieu; Lionel Tastet; Cedric Renard; Mesut Gun; William Steven Arthur Jenkins; Laurent Macron; Jacob W Sechrist; Joan M Lacomis; Virginia Nguyen; Laura Galian Gay; Hug Cuéllar Calabria; Ioannis Ntalas; Timothy Robert Graham Cartlidge; Bernard Prendergast; Ronak Rajani; Arturo Evangelista; João L Cavalcante; David E Newby; Philippe Pibarot; David Messika Zeitoun; Marc R Dweck
Journal:  Circ Cardiovasc Imaging       Date:  2018-03       Impact factor: 7.792

Review 10.  Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document.

Authors:  A Pieter Kappetein; Stuart J Head; Philippe Généreux; Nicolo Piazza; Nicolas M van Mieghem; Eugene H Blackstone; Thomas G Brott; David J Cohen; Donald E Cutlip; Gerrit-Anne van Es; Rebecca T Hahn; Ajay J Kirtane; Mitchell W Krucoff; Susheel Kodali; Michael J Mack; Roxana Mehran; Josep Rodés-Cabau; Pascal Vranckx; John G Webb; Stephan Windecker; Patrick W Serruys; Martin B Leon
Journal:  J Thorac Cardiovasc Surg       Date:  2012-10-16       Impact factor: 5.209

View more
  2 in total

1.  Paravalvular leak prediction after transcatheter aortic valve replacement with self-expandable prosthesis based on quantitative aortic calcification analysis.

Authors:  Agata Wiktorowicz; Adrian Wit; Krzysztof Piotr Malinowski; Artur Dziewierz; Lukasz Rzeszutko; Dariusz Dudek; Pawel Kleczynski
Journal:  Quant Imaging Med Surg       Date:  2021-02

2.  Does Aortic Valve Calcium Score Still Predict Death, Cardiovascular Outcomes, and Conductive Disturbances after Transcatheter Aortic Valve Replacement with New-Generation Prostheses?

Authors:  Alexandre Gamet; Adeline Chatelin; Jean Mergy; Pauline Bécat; Pierre Roumegou; Luc Christiaens
Journal:  J Cardiovasc Echogr       Date:  2020-08-17
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.