Literature DB >> 25186296

Live nephron imaging by MRI.

Chunqi Qian1, Xin Yu2, Nikorn Pothayee3, Stephen Dodd3, Nadia Bouraoud3, Robert Star4, Kevin Bennett5, Alan Koretsky3.   

Abstract

The local sensitivity of MRI can be improved with small MR detectors placed close to regions of interest. However, to maintain such sensitivity advantage, local detectors normally need to communicate with the external amplifier through cable connections, which prevent the use of local detectors as implantable devices. Recently, an integrated wireless amplifier was developed that can efficiently amplify and broadcast locally detected signals, so that the local sensitivity was enhanced without the need for cable connections. This integrated detector enabled the live imaging of individual glomeruli using negative contrast introduced by cationized ferritin, and the live imaging of renal tubules using positive contrast introduced by gadopentetate dimeglumine. Here, we utilized the high blood flow to image individual glomeruli as hyperintense regions without any contrast agent. These hyperintense regions were identified for pixels with signal intensities higher than the local average. Addition of Mn(2+) allowed the simultaneous detection of both glomeruli and renal tubules: Mn(2+) was primarily reabsorbed by renal tubules, which would be distinguished from glomeruli due to higher enhancement in T1-weighted MRI. Dynamic studies of Mn(2+) absorption confirmed the differential absorption affinity of glomeruli and renal tubules, potentially enabling the in vivo observation of nephron function.
Copyright © 2014 the American Physiological Society.

Entities:  

Keywords:  MRI; filtration; glomeruli; perfusion; renal tubules

Mesh:

Year:  2014        PMID: 25186296      PMCID: PMC4233281          DOI: 10.1152/ajprenal.00326.2014

Source DB:  PubMed          Journal:  Am J Physiol Renal Physiol        ISSN: 1522-1466


  21 in total

1.  AUTORADIOGRAPHIC OBSERVATIONS OF MANGANESE IN ADULT AND EMBRYO MICE.

Authors:  Y KOSHIDA; M KATO; T HARA
Journal:  Q J Exp Physiol Cogn Med Sci       Date:  1963-10

2.  Quantification of glomerular number and size distribution in normal rat kidneys using magnetic resonance imaging.

Authors:  Melanie Heilmann; Sabine Neudecker; Ivo Wolf; Lina Gubhaju; Carsten Sticht; Daniel Schock-Kusch; Wilhelm Kriz; John F Bertram; Lothar R Schad; Norbert Gretz
Journal:  Nephrol Dial Transplant       Date:  2011-06-03       Impact factor: 5.992

3.  The relationship between glomerular filtration rate and sodium reabsorption by the proximal tubule of the rat nephron.

Authors:  B M Brenner; C M Bennett; R W Berliner
Journal:  J Clin Invest       Date:  1968-06       Impact factor: 14.808

4.  Magnetic resonance histology of age-related nephropathy in the Sprague Dawley rat.

Authors:  Luke Xie; Rachel E Cianciolo; Brian Hulette; Ha Won Lee; Yi Qi; Gary Cofer; G Allan Johnson
Journal:  Toxicol Pathol       Date:  2012-04-13       Impact factor: 1.902

5.  Measuring glomerular number and size in perfused kidneys using MRI.

Authors:  Scott C Beeman; Min Zhang; Lina Gubhaju; Teresa Wu; John F Bertram; David H Frakes; Brian R Cherry; Kevin M Bennett
Journal:  Am J Physiol Renal Physiol       Date:  2011-03-16

Review 6.  The clinical importance of nephron mass.

Authors:  Valerie A Luyckx; Barry M Brenner
Journal:  J Am Soc Nephrol       Date:  2010-02-11       Impact factor: 10.121

Review 7.  Chronic partial ureteral obstruction and the developing kidney.

Authors:  Robert L Chevalier
Journal:  Pediatr Radiol       Date:  2007-12-11

8.  Evaluation of quantitative magnetic resonance imaging as a noninvasive technique for measuring renal scarring in a rabbit model of antiglomerular basement membrane disease.

Authors:  M H de Miguel; H N Yeung; M Goyal; J W Noh; A M Aisen; S H Phan; R C Wiggins
Journal:  J Am Soc Nephrol       Date:  1994-05       Impact factor: 10.121

9.  MRI of the basement membrane using charged nanoparticles as contrast agents.

Authors:  Kevin M Bennett; Hua Zhou; James P Sumner; Stephen J Dodd; Nadia Bouraoud; Kent Doi; Robert A Star; Alan P Koretsky
Journal:  Magn Reson Med       Date:  2008-09       Impact factor: 4.668

10.  Susceptibility tensor imaging of the kidney and its microstructural underpinnings.

Authors:  Luke Xie; Russell Dibb; Gary P Cofer; Wei Li; Peter J Nicholls; G Allan Johnson; Chunlei Liu
Journal:  Magn Reson Med       Date:  2014-04-02       Impact factor: 4.668

View more
  15 in total

1.  A Novel Expandable Catheter Wireless Amplified NMR Detector for MR Sensitivity Accessing the Kidney in Rodent Model.

Authors:  Roshan Timilsina; Chunqi Qian
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2019-01-04       Impact factor: 3.833

2.  Parallel magnetic resonance image reconstruction from a single-element parametric amplifier.

Authors:  Roshan Timilsina; Chunqi Qian
Journal:  Magn Reson Imaging       Date:  2019-08-16       Impact factor: 2.546

Review 3.  Current MRI techniques for the assessment of renal disease.

Authors:  Takamune Takahashi; Feng Wang; Christopher C Quarles
Journal:  Curr Opin Nephrol Hypertens       Date:  2015-05       Impact factor: 2.894

Review 4.  MRI tools for assessment of microstructure and nephron function of the kidney.

Authors:  Luke Xie; Kevin M Bennett; Chunlei Liu; G Allan Johnson; Jeff Lei Zhang; Vivian S Lee
Journal:  Am J Physiol Renal Physiol       Date:  2016-09-14

5.  4D MRI of polycystic kidneys from rapamycin-treated Glis3-deficient mice.

Authors:  Luke Xie; Yi Qi; Ergys Subashi; Grace Liao; Laura Miller-DeGraff; Anton M Jetten; G Allan Johnson
Journal:  NMR Biomed       Date:  2015-03-23       Impact factor: 4.044

6.  Sensory and optogenetically driven single-vessel fMRI.

Authors:  Xin Yu; Yi He; Maosen Wang; Hellmut Merkle; Stephen J Dodd; Afonso C Silva; Alan P Koretsky
Journal:  Nat Methods       Date:  2016-02-08       Impact factor: 28.547

Review 7.  Counting glomeruli and podocytes: rationale and methodologies.

Authors:  Victor G Puelles; John F Bertram
Journal:  Curr Opin Nephrol Hypertens       Date:  2015-05       Impact factor: 2.894

8.  High-resolution MRI of kidney microstructures at 7.05 T with an endo-colonic Wireless Amplified NMR detector.

Authors:  Xianchun Zeng; Shuangtao Ma; John M Kruger; Rongpin Wang; Xiaobo Tan; Chunqi Qian
Journal:  J Magn Reson       Date:  2019-04-25       Impact factor: 2.229

9.  Signal Sensitivity Enhancement of High-Spatial-Resolution MR Imaging with a Concatenated Cylindrical Parametric RF-Resonator.

Authors:  Roshan Timilsina; Baolei Fan; Chunqi Qian
Journal:  IEEE Sens J       Date:  2019-01-23       Impact factor: 3.301

10.  Wireless amplified NMR detector for improved visibility of image contrast in heterogeneous lesions.

Authors:  Xianchun Zeng; Shengqiang Xu; Changyong Cao; Jian Wang; Chunqi Qian
Journal:  NMR Biomed       Date:  2018-07-16       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.