PURPOSE: The purpose of this study was to determine whether susceptibility tensor imaging (STI) could overcome limitations of current techniques to detect tubules throughout the kidney. METHODS: Normal mouse kidneys (n = 4) were imaged at 9.4T using a three-dimensional gradient multi-echo sequence (55-micron isotropic resolution). Phase images from 12 orientations were obtained to compute the susceptibility tensor. Diffusion tensor imaging (DTI) with 12 encoding directions was compared with STI. Tractography was performed to visualize and track the course of tubules with DTI and STI. Confocal microscopy was used to identify which tubular segments of the nephron were detected by DTI and STI. RESULTS: Diffusion anisotropy was limited to the inner medulla of the kidney. DTI did not find a significant number of coherent tubular tracks in the outer medulla or cortex. With STI, we found strong susceptibility anisotropy and many tracks in the inner and outer medulla and in limited areas of the cortex. CONCLUSION: STI was able to track tubules throughout the kidney, whereas DTI was limited to the inner medulla. STI provides a novel contrast mechanism related to local tubule microstructure and may offer a powerful method to study the nephron.
PURPOSE: The purpose of this study was to determine whether susceptibility tensor imaging (STI) could overcome limitations of current techniques to detect tubules throughout the kidney. METHODS: Normal mouse kidneys (n = 4) were imaged at 9.4T using a three-dimensional gradient multi-echo sequence (55-micron isotropic resolution). Phase images from 12 orientations were obtained to compute the susceptibility tensor. Diffusion tensor imaging (DTI) with 12 encoding directions was compared with STI. Tractography was performed to visualize and track the course of tubules with DTI and STI. Confocal microscopy was used to identify which tubular segments of the nephron were detected by DTI and STI. RESULTS: Diffusion anisotropy was limited to the inner medulla of the kidney. DTI did not find a significant number of coherent tubular tracks in the outer medulla or cortex. With STI, we found strong susceptibility anisotropy and many tracks in the inner and outer medulla and in limited areas of the cortex. CONCLUSION:STI was able to track tubules throughout the kidney, whereas DTI was limited to the inner medulla. STI provides a novel contrast mechanism related to local tubule microstructure and may offer a powerful method to study the nephron.
Authors: M C Ortiz; A García-Sanz; M D Bentley; L A Fortepiani; J García-Estañ; E L Ritman; J C Romero; L A Juncos Journal: Kidney Int Date: 2000-10 Impact factor: 10.612
Authors: David A Nordsletten; Shane Blackett; Michael D Bentley; Erik L Ritman; Nicolas P Smith Journal: Am J Physiol Heart Circ Physiol Date: 2006-01-06 Impact factor: 4.733
Authors: Mike Notohamiprodjo; Christian Glaser; Karin A Herrmann; Olaf Dietrich; Ulrike I Attenberger; Maximilian F Reiser; Stefan O Schoenberg; Henrik J Michaely Journal: Invest Radiol Date: 2008-10 Impact factor: 6.016
Authors: Berkin Bilgic; Luke Xie; Russell Dibb; Christian Langkammer; Aysegul Mutluay; Huihui Ye; Jonathan R Polimeni; Jean Augustinack; Chunlei Liu; Lawrence L Wald; Kawin Setsompop Journal: Neuroimage Date: 2015-08-12 Impact factor: 6.556
Authors: Hyungseok Jang; Annette von Drygalski; Jonathan Wong; Jenny Y Zhou; Peter Aguero; Xing Lu; Xin Cheng; Scott T Ball; Yajun Ma; Eric Y Chang; Jiang Du Journal: Magn Reson Med Date: 2020-07-14 Impact factor: 4.668
Authors: Chunqi Qian; Xin Yu; Nikorn Pothayee; Stephen Dodd; Nadia Bouraoud; Robert Star; Kevin Bennett; Alan Koretsky Journal: Am J Physiol Renal Physiol Date: 2014-09-03
Authors: Hongjiang Wei; Eric Gibbs; Peida Zhao; Nian Wang; Gary P Cofer; Yuyao Zhang; G Allan Johnson; Chunlei Liu Journal: Magn Reson Med Date: 2017-08-30 Impact factor: 4.668