Literature DB >> 3279184

Accuracy of impression materials for complete-arch fixed partial dentures.

C C Lin1, G J Ziebert, S J Donegan, V B Dhuru.   

Abstract

The accuracy of 12 impression materials of six different types were studied by using complete-arch FPD impressions. Sixty impressions were made of a Columbia dentoform maxillary model with complete cast crown abutment preparations on the canines and the second molars. A one-piece casting was constructed by connecting the four individual castings made for the four abutment teeth. The master prosthesis was seated on the stone casts produced from the impressions. The marginal adaptation on the four abutments was then evaluated with a travelling microscope. The individual marginal adaptation of the four castings on the abutments was also examined after sectioning the four joints. The following conclusions were drawn. 1. The polyethers produced the most accurate complete-arch replicas. The second most accurate were the vinyl polysiloxanes, followed by the polysulfides and the irreversible-reversible hydrocolloids. The least accurate were the reversible hydrocolloids and the irreversible hydrocolloids. 2. The polyether impression materials exhibited the most consistent accuracy for a master cast to fabricate a complete-arch FPD.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3279184     DOI: 10.1016/0022-3913(88)90174-6

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  4 in total

1.  Dimensional accuracy of two rubber base impression materials as a function of spacer design and techniques in custom trays for fixed partial dentures.

Authors:  Pankaj Kaushik; R K Dhiman; Dinesh Kumar
Journal:  Med J Armed Forces India       Date:  2013-08-02

2.  Effect of temperature changes on the dimensional stability of elastomeric impression materials.

Authors:  Sujan Kambhampati; Vaddavalli Subhash; Chellagulla Vijay; Aruna Das
Journal:  J Int Oral Health       Date:  2014-02-26

3.  A Comparative Evaluation of Dimensional Accuracy and Surface Detail Reproduction of Four Hydrophilic Vinyl Polysiloxane Impression Materials Tested Under Dry, Moist, and Wet Conditions-An In Vitro Study.

Authors:  Rahul Nagrath; Manesh Lahori; Manjari Agrawal
Journal:  J Indian Prosthodont Soc       Date:  2014-05-11

4.  A Comparison of Dimensional Accuracy of Addition Silicone of Different Consistencies with Two Different Spacer Designs - In-vitro Study.

Authors:  Suprabha Rathee; B Eswaran; Ma Eswaran; R Prabhu; Kr Geetha; Gp Krishna
Journal:  J Clin Diagn Res       Date:  2014-07-20
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.