Literature DB >> 25173319

Analyzer-based phase-contrast imaging system using a micro focus X-ray source.

Wei Zhou1, Keivan Majidi2, Jovan G Brankov2.   

Abstract

Here we describe a new in-laboratory analyzer based phase contrast-imaging (ABI) instrument using a conventional X-ray tube source (CXS) aimed at bio-medical imaging applications. Phase contrast-imaging allows visualization of soft tissue details usually obscured in conventional X-ray imaging. The ABI system design and major features are described in detail. The key advantage of the presented system, over the few existing CXS ABI systems, is that it does not require high precision components, i.e., CXS, X-ray detector, and electro-mechanical components. To overcome a main problem introduced by these components, identified as temperature stability, the system components are kept at a constant temperature inside of three enclosures, thus minimizing the electrical and mechanical thermal drifts. This is achieved by using thermoelectric (Peltier) cooling/heating modules that are easy to control precisely. For CXS we utilized a microfocus X-ray source with tungsten (W) anode material. In addition the proposed system eliminates tungsten's multiple spectral lines by selecting monochromator crystal size appropriately therefore eliminating need for the costly mismatched, two-crystal monochromator. The system imaging was fine-tuned for tungsten Kα1 line with the energy of 59.3 keV since it has been shown to be of great clinical significance by a number of researchers at synchrotron facilities. In this way a laboratory system that can be used for evaluating and quantifying tissue properties, initially explored at synchrotron facilities, would be of great interest to a larger research community. To demonstrate the imaging capability of our instrument we use a chicken thigh tissue sample.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25173319      PMCID: PMC4141915          DOI: 10.1063/1.4890281

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  15 in total

1.  Multiple-image radiography.

Authors:  Miles N Wernick; Oliver Wirjadi; Dean Chapman; Zhong Zhong; Nikolas P Galatsanos; Yongyi Yang; Jovan G Brankov; Oral Oltulu; Mark A Anastasio; Carol Muehleman
Journal:  Phys Med Biol       Date:  2003-12-07       Impact factor: 3.609

2.  Phase contrast image segmentation using a Laue analyser crystal.

Authors:  Marcus J Kitchen; David M Paganin; Kentaro Uesugi; Beth J Allison; Robert A Lewis; Stuart B Hooper; Konstantin M Pavlov
Journal:  Phys Med Biol       Date:  2011-01-06       Impact factor: 3.609

3.  Multiple-image radiography for human soft tissue.

Authors:  Carol Muehleman; Jun Li; Zhong Zhong; Jovan G Brankov; Miles N Wernick
Journal:  J Anat       Date:  2006-01       Impact factor: 2.610

4.  Preliminary study on diffraction enhanced radiographic imaging for a canine model of cartilage damage.

Authors:  C Muehleman; J Li; Z Zhong
Journal:  Osteoarthritis Cartilage       Date:  2006-04-18       Impact factor: 6.576

5.  Design and implementation of a compact low-dose diffraction enhanced medical imaging system.

Authors:  Christopher Parham; Zhong Zhong; Dean M Connor; L Dean Chapman; Etta D Pisano
Journal:  Acad Radiol       Date:  2009-04-17       Impact factor: 3.173

6.  Effect of breast compression on lesion characteristic visibility with diffraction-enhanced imaging.

Authors:  Laura S Faulconer; Chris A Parham; Dean M Connor; Cherie Kuzmiak; Marcia Koomen; Yeonhee Lee; Kyu Ran Cho; Josh Rafoth; Chad A Livasy; Eunhee Kim; Donglin Zeng; Elodia Cole; Zhong Zhong; Etta D Pisano
Journal:  Acad Radiol       Date:  2009-12-29       Impact factor: 3.173

7.  The design and application of an in-laboratory diffraction-enhanced x-ray imaging instrument.

Authors:  Ivan Nesch; Daniel P Fogarty; Tochko Tzvetkov; Benjamin Reinhart; A Charles Walus; Gocha Khelashvili; Carol Muehleman; Dean Chapman
Journal:  Rev Sci Instrum       Date:  2009-09       Impact factor: 1.523

8.  Radiologist evaluation of an X-ray tube-based diffraction-enhanced imaging prototype using full-thickness breast specimens.

Authors:  Laura Faulconer; Chris Parham; Dean M Connor; Zhong Zhong; Eunhee Kim; Donglin Zeng; Chad Livasy; Elodia Cole; Cherie Kuzmiak; Marcia Koomen; Dag Pavic; Etta Pisano
Journal:  Acad Radiol       Date:  2009-07-10       Impact factor: 3.173

9.  Source effects in analyzer-based X-ray phase contrast imaging with conventional sources.

Authors:  M G Hönnicke; J Manica; I Mazzaro; C Cusatis; X-R Huang
Journal:  Rev Sci Instrum       Date:  2012-11       Impact factor: 1.523

10.  X-ray tomography using the full complex index of refraction.

Authors:  M S Nielsen; T Lauridsen; M Thomsen; T H Jensen; M Bech; L B Christensen; E V Olsen; M Hviid; R Feidenhans'l; F Pfeiffer
Journal:  Phys Med Biol       Date:  2012-09-11       Impact factor: 3.609

View more
  5 in total

1.  Phase-contrast imaging with a compact x-ray light source: system design.

Authors:  Yongjin Sung; Rajiv Gupta; Brandon Nelson; Shuai Leng; Cynthia H McCollough; William S Graves
Journal:  J Med Imaging (Bellingham)       Date:  2017-11-23

2.  In Vitro Validation of an Artefact Suppression Algorithm in X-Ray Phase-Contrast Computed Tomography.

Authors:  Naoki Sunaguchi; Tetsuya Yuasa; Shin-Ichi Hirano; Rajiv Gupta; Masami Ando
Journal:  PLoS One       Date:  2015-08-21       Impact factor: 3.240

3.  Realistic wave-optics simulation of X-ray phase-contrast imaging at a human scale.

Authors:  Yongjin Sung; W Paul Segars; Adam Pan; Masami Ando; Colin J R Sheppard; Rajiv Gupta
Journal:  Sci Rep       Date:  2015-07-14       Impact factor: 4.379

Review 4.  Recent advances in edge illumination x-ray phase-contrast tomography.

Authors:  Anna Zamir; Charlotte Hagen; Paul C Diemoz; Marco Endrizzi; Fabio Vittoria; Yujia Chen; Mark A Anastasio; Alessandro Olivo
Journal:  J Med Imaging (Bellingham)       Date:  2017-10-16

Review 5.  Early Diagnosis and Real-Time Monitoring of Regional Lung Function Changes to Prevent Chronic Obstructive Pulmonary Disease Progression to Severe Emphysema.

Authors:  Tony Jung; Neeraj Vij
Journal:  J Clin Med       Date:  2021-12-12       Impact factor: 4.241

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.