Literature DB >> 25169028

Effectiveness of the ICare rebound tonometer in patients with overestimated intraocular pressure due to tight orbit syndrome.

You Kyung Lee1, Y K Lee, Ji Young Lee, J Y Lee, Jung Il Moon, J I Moon, Myoung Hee Park, M H Park.   

Abstract

PURPOSE: To evaluate the effectiveness of the ICare rebound tonometer in patients with overestimated intraocular pressure (IOP) due to tight orbit syndrome and to identify factors affecting the development of tight orbit syndrome in glaucoma patients.
METHODS: We investigated 84 eyes in 84 glaucoma patients, of which 14 eyes were classified in the tight orbit syndrome group and 70 eyes in the control group. IOP was measured using the ICare tonometer and the Goldmann applanation tonometer (GAT). The demographic data, medical histories, ocular histories, and detailed ocular drug histories of the two groups were compared to identify factors contributing to the development of tight orbit syndrome.
RESULTS: In the tight orbit syndrome group, the ICare tonometer significantly underestimated the IOP by approximately 8.6 mmHg compared with the GAT. In the control group, the IOP readings of the GAT and the ICare tonometer did not differ significantly. Bland-Altman analysis showed that the mean difference between measurements taken using the GAT and those taken using the ICare tonometer was 2.5 ± 6.3 mmHg. The difference between the GAT and ICare tonometer measurements was greater in the tight orbit syndrome group (8.6 ± 5.3 mmHg) than in the control group (1.3 ± 2.7 mmHg). Multivariate regression analysis revealed that only the use of prostaglandin analogs (PGAs) was associated with the development of tight orbit syndrome.
CONCLUSIONS: The ICare tonometer is a suitable alternative device for use in patients with tight orbit syndrome in whom the IOP may be overestimated with the GAT. The prolonged use of PGAs is significantly associated with the development of tight orbit syndrome.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25169028     DOI: 10.1007/s10384-014-0343-3

Source DB:  PubMed          Journal:  Jpn J Ophthalmol        ISSN: 0021-5155            Impact factor:   2.447


  34 in total

1.  Determining in vivo biomechanical properties of the cornea with an ocular response analyzer.

Authors:  David A Luce
Journal:  J Cataract Refract Surg       Date:  2005-01       Impact factor: 3.351

Review 2.  Side effects associated with prostaglandin analog therapy.

Authors:  Albert Alm; Ian Grierson; M Bruce Shields
Journal:  Surv Ophthalmol       Date:  2008-11       Impact factor: 6.048

3.  Standardizing the measurement of intraocular pressure for clinical research. Guidelines from the Eye Care Technology Forum.

Authors:  M A Kass
Journal:  Ophthalmology       Date:  1996-01       Impact factor: 12.079

4.  Comparison of intraocular pressure measurements and assessment of intraobserver and interobserver reproducibility with the portable ICare rebound tonometer and Goldmann applanation tonometer in glaucoma patients.

Authors:  Sarwat Salim; Haiming Du; Jim Wan
Journal:  J Glaucoma       Date:  2013 Apr-May       Impact factor: 2.503

5.  Comparison of ICare tonometer with Goldmann applanation tonometer in glaucoma patients.

Authors:  Paolo Brusini; Maria Letizia Salvetat; Marco Zeppieri; Claudia Tosoni; Lucia Parisi
Journal:  J Glaucoma       Date:  2006-06       Impact factor: 2.503

Review 6.  Sources of error with use of Goldmann-type tonometers.

Authors:  M M Whitacre; R Stein
Journal:  Surv Ophthalmol       Date:  1993 Jul-Aug       Impact factor: 6.048

7.  Prostaglandins promote and block adipogenesis through opposing effects on peroxisome proliferator-activated receptor gamma.

Authors:  M J Reginato; S L Krakow; S T Bailey; M A Lazar
Journal:  J Biol Chem       Date:  1998-01-23       Impact factor: 5.157

8.  [Orbital fat atrophy in glaucoma patients treated with topical bimatoprost--can bimatoprost cause enophthalmos?].

Authors:  C Tappeiner; B Perren; M E Iliev; B E Frueh; D Goldblum
Journal:  Klin Monbl Augenheilkd       Date:  2008-05       Impact factor: 0.700

9.  Prostaglandin F2alpha stimulates the expression and secretion of transforming growth factor B1 via induction of the early growth response 1 gene (EGR1) in the bovine corpus luteum.

Authors:  Xiaoying Hou; Edward W Arvisais; Chao Jiang; Dong-bao Chen; Shyamal K Roy; Joy L Pate; Thomas R Hansen; Bo R Rueda; John S Davis
Journal:  Mol Endocrinol       Date:  2007-10-04

Review 10.  Update on prostaglandin analogs.

Authors:  Camille Hylton; Alan L Robin
Journal:  Curr Opin Ophthalmol       Date:  2003-04       Impact factor: 3.761

View more
  3 in total

Review 1.  Prostanoid receptor agonists for glaucoma treatment.

Authors:  Makoto Aihara
Journal:  Jpn J Ophthalmol       Date:  2021-07-06       Impact factor: 2.447

2.  Factors associated with fluctuations in repeated measurements of intraocular pressure using the Goldmann applanation tonometer in Japanese patients with primary open-angle glaucoma.

Authors:  Kiyoshi Yaoeda; Atsushi Fukushima; Motohiro Shirakashi; Atsushi Miki; Takeo Fukuchi
Journal:  Clin Ophthalmol       Date:  2018-08-17

3.  Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer.

Authors:  Feng Gao; Xu Liu; Qing Zhao; Yingzhe Pan
Journal:  Exp Ther Med       Date:  2017-02-24       Impact factor: 2.447

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.