Literature DB >> 25158126

Smartphone-based simultaneous pH and nitrite colorimetric determination for paper microfluidic devices.

Nuria Lopez-Ruiz1, Vincenzo F Curto, Miguel M Erenas, Fernando Benito-Lopez, Dermot Diamond, Alberto J Palma, Luis F Capitan-Vallvey.   

Abstract

In this work, an Android application for measurement of nitrite concentration and pH determination in combination with a low-cost paper-based microfluidic device is presented. The application uses seven sensing areas, containing the corresponding immobilized reagents, to produce selective color changes when a sample solution is placed in the sampling area. Under controlled conditions of light, using the flash of the smartphone as a light source, the image captured with the built-in camera is processed using a customized algorithm for multidetection of the colored sensing areas. The developed image-processing allows reducing the influence of the light source and the positioning of the microfluidic device in the picture. Then, the H (hue) and S (saturation) coordinates of the HSV color space are extracted and related to pH and nitrite concentration, respectively. A complete characterization of the sensing elements has been carried out as well as a full description of the image analysis for detection. The results show good use of a mobile phone as an analytical instrument. For the pH, the resolution obtained is 0.04 units of pH, 0.09 of accuracy, and a mean squared error of 0.167. With regard to nitrite, 0.51% at 4.0 mg L(-1) of resolution and 0.52 mg L(-1) as the limit of detection was achieved.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25158126     DOI: 10.1021/ac5019205

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  40 in total

1.  Comparative Chemometric Analysis for Classification of Acids and Bases via a Colorimetric Sensor Array.

Authors:  Michael J Kangas; Raychelle M Burks; Jordyn Atwater; Rachel M Lukowicz; Billy Garver; Andrea E Holmes
Journal:  J Chemom       Date:  2017-10-13       Impact factor: 2.467

Review 2.  Strategies for the detection of target analytes using microfluidic paper-based analytical devices.

Authors:  Wei Zheng; Kan Wang; Hao Xu; Chujun Zheng; Bo Cao; Qi Qin; Qinghui Jin; Daxiang Cui
Journal:  Anal Bioanal Chem       Date:  2021-03-13       Impact factor: 4.142

3.  A colorimetric paper-based ATONP-ALP nanobiosensor for selective detection of Cd2+ ions in clams and mussels.

Authors:  Krishna Kumari Swain; Sunil Bhand
Journal:  Anal Bioanal Chem       Date:  2021-02-10       Impact factor: 4.142

Review 4.  Novel developments in mobile sensing based on the integration of microfluidic devices and smartphones.

Authors:  Ke Yang; Hagit Peretz-Soroka; Yong Liu; Francis Lin
Journal:  Lab Chip       Date:  2016-02-22       Impact factor: 6.799

Review 5.  New nucleic acid testing devices to diagnose infectious diseases in resource-limited settings.

Authors:  P Maffert; S Reverchon; W Nasser; C Rozand; H Abaibou
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2017-06-01       Impact factor: 3.267

6.  Smartphone-enabled field monitoring tool for rapid hexavalent chromium detection in water.

Authors:  Sushant D Bamane; Vinod Bhojwani; Pradeep L Balkunde; Mainak Bhattacharya; Ishan Gupta; Ashwini K Mohapatra; Aditya Shekhar; Abhas Singh
Journal:  Anal Bioanal Chem       Date:  2021-04-02       Impact factor: 4.142

7.  Colorimetric-Luminance Readout for Quantitative Analysis of Fluorescence Signals with a Smartphone CMOS Sensor.

Authors:  Aashish Priye; Cameron S Ball; Robert J Meagher
Journal:  Anal Chem       Date:  2018-10-16       Impact factor: 6.986

8.  Paper-based plasticizer-free sodium ion-selective sensor with camera phone as a detector.

Authors:  Xuewei Wang; Yu Qin; Mark E Meyerhoff
Journal:  Chem Commun (Camb)       Date:  2015-09-01       Impact factor: 6.222

9.  A Strategy for Minimizing Background Signal in Autoinductive Signal Amplification Reactions for Point-of-Need Assays.

Authors:  Adam D Brooks; Kimy Yeung; Gregory G Lewis; Scott T Phillips
Journal:  Anal Methods       Date:  2015-03-06       Impact factor: 2.896

Review 10.  Point-of-Care Diagnostics: Recent Developments in a Connected Age.

Authors:  Samiksha Nayak; Nicole R Blumenfeld; Tassaneewan Laksanasopin; Samuel K Sia
Journal:  Anal Chem       Date:  2016-12-13       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.