Literature DB >> 25157685

Range assessment in particle therapy based on prompt γ-ray timing measurements.

Christian Golnik1, Fernando Hueso-González, Andreas Müller, Peter Dendooven, Wolfgang Enghardt, Fine Fiedler, Thomas Kormoll, Katja Roemer, Johannes Petzoldt, Andreas Wagner, Guntram Pausch.   

Abstract

Proton and ion beams open up new vistas for the curative treatment of tumors, but adequate technologies for monitoring the compliance of dose delivery with treatment plans in real time are still missing. Range assessment, meaning the monitoring of therapy-particle ranges in tissue during dose delivery (treatment), is a continuous challenge considered a key for tapping the full potential of particle therapies. In this context the paper introduces an unconventional concept of range assessment by prompt-gamma timing (PGT), which is based on an elementary physical effect not considered so far: therapy particles penetrating tissue move very fast, but still need a finite transit time--about 1-2 ns in case of protons with a 5-20 cm range--from entering the patient's body until stopping in the target volume. The transit time increases with the particle range. This causes measurable effects in PGT spectra, usable for range verification. The concept was verified by proton irradiation experiments at the AGOR cyclotron, KVI-CART, University of Groningen. Based on the presented kinematical relations, we describe model calculations that very precisely reproduce the experimental results. As the clinical treatment conditions entail measurement constraints (e.g. limited treatment time), we propose a setup, based on clinical irradiation conditions, capable of determining proton range deviations within a few seconds of irradiation, thus allowing for a fast safety survey. Range variations of 2 mm are expected to be clearly detectable.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25157685     DOI: 10.1088/0031-9155/59/18/5399

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  26 in total

1.  Acoustic-based proton range verification in heterogeneous tissue: simulation studies.

Authors:  Kevin C Jones; Wei Nie; James C H Chu; Julius V Turian; Alireza Kassaee; Chandra M Sehgal; Stephen Avery
Journal:  Phys Med Biol       Date:  2018-01-11       Impact factor: 3.609

Review 2.  Radiation oncology in the era of precision medicine.

Authors:  Michael Baumann; Mechthild Krause; Jens Overgaard; Jürgen Debus; Søren M Bentzen; Juliane Daartz; Christian Richter; Daniel Zips; Thomas Bortfeld
Journal:  Nat Rev Cancer       Date:  2016-03-18       Impact factor: 60.716

Review 3.  Empowering Intensity Modulated Proton Therapy Through Physics and Technology: An Overview.

Authors:  Radhe Mohan; Indra J Das; Clifton C Ling
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-10-01       Impact factor: 7.038

Review 4.  In vivo range verification in particle therapy.

Authors:  Katia Parodi; Jerimy C Polf
Journal:  Med Phys       Date:  2018-11       Impact factor: 4.071

5.  First Cerenkov charge-induction (CCI) TlBr detector for TOF-PET and proton range verification.

Authors:  Gerard Ariño-Estrada; Gregory S Mitchell; Hadong Kim; Junwei Du; Sun Il Kwon; Leonard J Cirignano; Kanai S Shah; Simon R Cherry
Journal:  Phys Med Biol       Date:  2019-08-28       Impact factor: 3.609

6.  Compact Method for Proton Range Verification Based on Coaxial Prompt Gamma-Ray Monitoring: a Theoretical Study.

Authors:  F Hueso-González; T Bortfeld
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-07-23

7.  The effects of Compton camera data acquisition and readout timing on PG imaging for proton range verification.

Authors:  Jerimy C Polf; Paul Maggi; Rajesh Panthi; Stephen Peterson; Dennis Mackin; Sam Beddar
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2021-02-05

8.  A full-scale clinical prototype for proton range verification using prompt gamma-ray spectroscopy.

Authors:  Fernando Hueso-González; Moritz Rabe; Thomas A Ruggieri; Thomas Bortfeld; Joost M Verburg
Journal:  Phys Med Biol       Date:  2018-09-17       Impact factor: 3.609

Review 9.  Latest developments in in-vivo imaging for proton therapy.

Authors:  Katia Parodi
Journal:  Br J Radiol       Date:  2019-12-12       Impact factor: 3.039

10.  Prompt gamma imaging for the identification of regional proton range deviations due to anatomic change in a heterogeneous region.

Authors:  Yunhe Xie; Johannes Petzoldt; Guillaume Janssens; Fionnbarr O'Grady; Lingshu Yin; El Hassane Bentefour; Julien Smeets; Damien Prieels; Robert A Lustig; Alexander Lin; Boon-Keng Teo
Journal:  Br J Radiol       Date:  2020-10-06       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.