Literature DB >> 25154715

Optimal diffusion weighting for in vivo cardiac diffusion tensor imaging.

Andrew D Scott1,2, Pedro F A D C Ferreira1,2, Sonia Nielles-Vallespin1,3, Peter Gatehouse1,2, Laura-Ann McGill1,2, Philip Kilner1,2, Dudley J Pennell1,2, David N Firmin1,2.   

Abstract

PURPOSE: To investigate the influence of the diffusion weighting on in vivo cardiac diffusion tensor imaging (cDTI) and obtain optimal parameters.
METHODS: Ten subjects were scanned using stimulated echo acquisition mode echo planar imaging with six b-values, from 50 to 950 s·mm(-2) , plus b = 15 s·mm(-2) reference. The relationship between b-value and both signal loss and signal-to-noise ratio measures was investigated. Mean diffusivity, fractional anisotropy, and helical angle maps were calculated using all possible b-value pairs to investigate the effects of diffusion weighting on the main and reference data.
RESULTS: Signal decay at low b-values was dominated by processes with high apparent diffusion coefficients, most likely microvascular perfusion. This effect could be avoided by diffusion weighting of the reference images. Parameter maps were improved with increased b-value until the diffusion-weighted signal approached the noise floor. For the protocol used in this study, b = 750 s·mm(-2) combined with 150 s·mm(-2) diffusion weighting of the reference images proved optimal.
CONCLUSION: Mean diffusivity, fractional anisotropy, and helical angle from cDTI are influenced by the b-value of the main and reference data. Using optimal values improves parameter maps and avoids microvascular perfusion effects. This optimized protocol should provide greater sensitivity to pathological changes in parameter maps.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  DTI; b-value; cardiac diffusion; diffusion weighting; microvascular perfusion

Mesh:

Year:  2014        PMID: 25154715     DOI: 10.1002/mrm.25418

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  24 in total

1.  Orientation dependence of microcirculation-induced diffusion signal in anisotropic tissues.

Authors:  Osama M Abdullah; Arnold David Gomez; Samer Merchant; Michael Heidinger; Steven Poelzing; Edward W Hsu
Journal:  Magn Reson Med       Date:  2015-10-29       Impact factor: 4.668

2.  Quantifying precision in cardiac diffusion tensor imaging with second-order motion-compensated convex optimized diffusion encoding.

Authors:  Eric Aliotta; Kévin Moulin; Patrick Magrath; Daniel B Ennis
Journal:  Magn Reson Med       Date:  2018-02-09       Impact factor: 4.668

3.  Diffusion tensor imaging and histology of developing hearts.

Authors:  Osama M Abdullah; Thomas Seidel; MarJanna Dahl; Arnold David Gomez; Gavin Yiep; Julia Cortino; Frank B Sachse; Kurt H Albertine; Edward W Hsu
Journal:  NMR Biomed       Date:  2016-08-03       Impact factor: 4.044

4.  Motion-Induced Signal Loss in In Vivo Cardiac Diffusion-Weighted Imaging.

Authors:  Christian T Stoeck; Andrew D Scott; Pedro F Ferreira; Elizabeth M Tunnicliffe; Irvin Teh; Sonia Nielles-Vallespin; Kevin Moulin; David E Sosnovik; Magalie Viallon; Pierre Croisille; Sebastian Kozerke; David N Firmin; Daniel B Ennis; Jurgen E Schneider
Journal:  J Magn Reson Imaging       Date:  2019-04-29       Impact factor: 4.813

5.  Diffusion Tensor Cardiovascular Magnetic Resonance in Cardiac Amyloidosis.

Authors:  David N Firmin; Dudley J Pennell; Zohya Khalique; Pedro F Ferreira; Andrew D Scott; Sonia Nielles-Vallespin; Ana Martinez-Naharro; Marianna Fontana; Phillip Hawkins
Journal:  Circ Cardiovasc Imaging       Date:  2020-05-15       Impact factor: 7.792

6.  Evaluation of the impact of strain correction on the orientation of cardiac diffusion tensors with in vivo and ex vivo porcine hearts.

Authors:  Pedro F Ferreira; Sonia Nielles-Vallespin; Andrew D Scott; Ranil de Silva; Philip J Kilner; Daniel B Ennis; Daniel A Auger; Jonathan D Suever; Xiaodong Zhong; Bruce S Spottiswoode; Dudley J Pennell; Andrew E Arai; David N Firmin
Journal:  Magn Reson Med       Date:  2017-07-21       Impact factor: 4.668

7.  Diffusion Tractography of the Entire Left Ventricle by Using Free-breathing Accelerated Simultaneous Multisection Imaging.

Authors:  Choukri Mekkaoui; Timothy G Reese; Marcel P Jackowski; Stephen F Cauley; Kawin Setsompop; Himanshu Bhat; David E Sosnovik
Journal:  Radiology       Date:  2016-09-28       Impact factor: 11.105

8.  Classification of heart failure: A farewell to ejection fraction?

Authors:  Thomas F Lüscher
Journal:  Anatol J Cardiol       Date:  2021-01       Impact factor: 1.475

9.  Comparison of interpolation methods of predominant cardiomyocyte orientation from in vivo and ex vivo cardiac diffusion tensor imaging data.

Authors:  Johanna Stimm; Christian Guenthner; Sebastian Kozerke; Christian T Stoeck
Journal:  NMR Biomed       Date:  2021-12-29       Impact factor: 4.478

10.  Comparison of diffusion tensor imaging by cardiovascular magnetic resonance and gadolinium enhanced 3D image intensity approaches to investigation of structural anisotropy in explanted rat hearts.

Authors:  Olivier Bernus; Aleksandra Radjenovic; Mark L Trew; Ian J LeGrice; Gregory B Sands; Derek R Magee; Bruce H Smaill; Stephen H Gilbert
Journal:  J Cardiovasc Magn Reson       Date:  2015-04-29       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.