Literature DB >> 27681278

Diffusion Tractography of the Entire Left Ventricle by Using Free-breathing Accelerated Simultaneous Multisection Imaging.

Choukri Mekkaoui1, Timothy G Reese1, Marcel P Jackowski1, Stephen F Cauley1, Kawin Setsompop1, Himanshu Bhat1, David E Sosnovik1.   

Abstract

Purpose To develop a clinically feasible whole-heart free-breathing diffusion-tensor (DT) magnetic resonance (MR) imaging approach with an imaging time of approximately 15 minutes to enable three-dimensional (3D) tractography. Materials and Methods The study was compliant with HIPAA and the institutional review board and required written consent from the participants. DT imaging was performed in seven healthy volunteers and three patients with pulmonary hypertension by using a stimulated echo sequence. Twelve contiguous short-axis sections and six four-chamber sections that covered the entire left ventricle were acquired by using simultaneous multisection (SMS) excitation with a blipped-controlled aliasing in parallel imaging readout. Rate 2 and rate 3 SMS excitation was defined as two and three times accelerated in the section axis, respectively. Breath-hold and free-breathing images with and without SMS acceleration were acquired. Diffusion-encoding directions were acquired sequentially, spatiotemporally registered, and retrospectively selected by using an entropy-based approach. Myofiber helix angle, mean diffusivity, fractional anisotropy, and 3D tractograms were analyzed by using paired t tests and analysis of variance. Results No significant differences (P > .63) were seen between breath-hold rate 3 SMS and free-breathing rate 2 SMS excitation in transmural myofiber helix angle, mean diffusivity (mean ± standard deviation, [0.89 ± 0.09] × 10-3 mm2/sec vs [0.9 ± 0.09] × 10-3 mm2/sec), or fractional anisotropy (0.43 ± 0.05 vs 0.42 ± 0.06). Three-dimensional tractograms of the left ventricle with no SMS and rate 2 and rate 3 SMS excitation were qualitatively similar. Conclusion Free-breathing DT imaging of the entire human heart can be performed in approximately 15 minutes without section gaps by using SMS excitation with a blipped-controlled aliasing in parallel imaging readout, followed by spatiotemporal registration and entropy-based retrospective image selection. This method may lead to clinical translation of whole-heart DT imaging, enabling broad application in patients with cardiac disease. © RSNA, 2016 Online supplemental material is available for this article.

Entities:  

Mesh:

Year:  2016        PMID: 27681278      PMCID: PMC5318239          DOI: 10.1148/radiol.2016152613

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  25 in total

1.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

2.  Information entropy measure for evaluation of image quality.

Authors:  Du-Yih Tsai; Yongbum Lee; Eri Matsuyama
Journal:  J Digit Imaging       Date:  2008-09       Impact factor: 4.056

3.  Histological validation of myocardial microstructure obtained from diffusion tensor magnetic resonance imaging.

Authors:  D F Scollan; A Holmes; R Winslow; J Forder
Journal:  Am J Physiol       Date:  1998-12

4.  Toward a quantitative assessment of diffusion anisotropy.

Authors:  C Pierpaoli; P J Basser
Journal:  Magn Reson Med       Date:  1996-12       Impact factor: 4.668

5.  Second-order motion-compensated spin echo diffusion tensor imaging of the human heart.

Authors:  Christian T Stoeck; Constantin von Deuster; Martin Genet; David Atkinson; Sebastian Kozerke
Journal:  Magn Reson Med       Date:  2015-05-28       Impact factor: 4.668

6.  Imaging myocardial fiber architecture in vivo with magnetic resonance.

Authors:  T G Reese; R M Weisskoff; R N Smith; B R Rosen; R E Dinsmore; V J Wedeen
Journal:  Magn Reson Med       Date:  1995-12       Impact factor: 4.668

7.  Posterior papillary muscle anchoring affects remote myofiber stress and pump function: finite element analysis.

Authors:  Joe Luis Pantoja; Liang Ge; Zhihong Zhang; William G Morrel; Julius M Guccione; Eugene A Grossi; Mark B Ratcliffe
Journal:  Ann Thorac Surg       Date:  2014-08-15       Impact factor: 4.330

Review 8.  Whole-heart modeling: applications to cardiac electrophysiology and electromechanics.

Authors:  Natalia A Trayanova
Journal:  Circ Res       Date:  2011-01-07       Impact factor: 17.367

9.  Sequential changes of myocardial microstructure in patients postmyocardial infarction by diffusion-tensor cardiac MR: correlation with left ventricular structure and function.

Authors:  Ming-Ting Wu; Mao-Yuan M Su; Yi-Luan Huang; Kuan-Rau Chiou; Pinchen Yang; Huay-Ben Pan; Timothy G Reese; Van J Wedeen; Wen-Yih I Tseng
Journal:  Circ Cardiovasc Imaging       Date:  2009-01       Impact factor: 7.792

10.  Accelerated human cardiac diffusion tensor imaging using simultaneous multislice imaging.

Authors:  Angus Z Lau; Elizabeth M Tunnicliffe; Robert Frost; Peter J Koopmans; Damian J Tyler; Matthew D Robson
Journal:  Magn Reson Med       Date:  2014-03-21       Impact factor: 4.668

View more
  14 in total

Review 1.  Magnetic Resonance-Based Characterization of Myocardial Architecture.

Authors:  David E Sosnovik
Journal:  Heart Fail Clin       Date:  2020-10-28       Impact factor: 3.179

2.  Exercise-induced CITED4 expression is necessary for regional remodeling of cardiac microstructural tissue helicity.

Authors:  Robert A Eder; Maaike van den Boomen; Salva R Yurista; Yaiel G Rodriguez-Aviles; Mohammad Rashedul Islam; Yin-Ching Iris Chen; Lena Trager; Jaume Coll-Font; Leo Cheng; Haobo Li; Anthony Rosenzweig; Christiane D Wrann; Christopher T Nguyen
Journal:  Commun Biol       Date:  2022-07-04

3.  Imaging the Microstructure of the Human Fetal Heart.

Authors:  David E Sosnovik; Tal Geva
Journal:  Circ Cardiovasc Imaging       Date:  2018-10       Impact factor: 7.792

4.  Free-breathing diffusion tensor MRI of the whole left ventricle using second-order motion compensation and multitasking respiratory motion correction.

Authors:  Christopher T Nguyen; Anthony G Christodoulou; Jaume Coll-Font; Sen Ma; Yibin Xie; Timothy G Reese; Choukri Mekkaoui; Gregory D Lewis; Xiaoming Bi; David E Sosnovik; Debiao Li
Journal:  Magn Reson Med       Date:  2020-11-30       Impact factor: 4.668

5.  Changes in overall ventricular myocardial architecture in the setting of a porcine animal model of right ventricular dilation.

Authors:  Peter Agger; Christine Ilkjær; Christoffer Laustsen; Morten Smerup; Jesper R Frandsen; Steffen Ringgaard; Michael Pedersen; John B Partridge; Robert H Anderson; Vibeke Hjortdal
Journal:  J Cardiovasc Magn Reson       Date:  2017-11-27       Impact factor: 5.364

6.  Myocardial Scar Delineation Using Diffusion Tensor Magnetic Resonance Tractography.

Authors:  Choukri Mekkaoui; Marcel P Jackowski; William J Kostis; Christian T Stoeck; Aravinda Thiagalingam; Timothy G Reese; Vivek Y Reddy; Jeremy N Ruskin; Sebastian Kozerke; David E Sosnovik
Journal:  J Am Heart Assoc       Date:  2018-02-02       Impact factor: 5.501

Review 7.  An Overview on Image Registration Techniques for Cardiac Diagnosis and Treatment.

Authors:  Azira Khalil; Siew-Cheok Ng; Yih Miin Liew; Khin Wee Lai
Journal:  Cardiol Res Pract       Date:  2018-08-08       Impact factor: 1.866

8.  Diffusion Tensor CMR: A Novel Approach for Evaluation of Myocardial Regeneration.

Authors:  Albert J Sinusas; Dana C Peters
Journal:  JACC Basic Transl Sci       Date:  2018-03-01

9.  Spin echo based cardiac diffusion imaging at 7T: An ex vivo study of the porcine heart at 7T and 3T.

Authors:  David Lohr; Maxim Terekhov; Andreas Max Weng; Anja Schroeder; Heike Walles; Laura Maria Schreiber
Journal:  PLoS One       Date:  2019-03-25       Impact factor: 3.240

10.  Myofiber strain in healthy humans using DENSE and cDTI.

Authors:  Kévin Moulin; Pierre Croisille; Magalie Viallon; Ilya A Verzhbinsky; Luigi E Perotti; Daniel B Ennis
Journal:  Magn Reson Med       Date:  2021-02-22       Impact factor: 3.737

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.