Literature DB >> 25152641

Porous high-density polyethylene in functional rhinoplasty: Excellent long-term aesthetic results and safety.

Young Hyo Kim1, Tae Young Jang1.   

Abstract

BACKGROUND: Experience with the use of porous high-density polyethylene (PHDPE) for reconstruction of the nasal framework has been limited.
OBJECTIVE: To confirm the safety and utility of PHDPE by analyzing aesthetic outcomes and assessing the frequency of complication related to PHDPE in a large, population-based, long-term follow-up study.
METHODS: A total of 151 patients who had undergone septoplasty and/or functional rhinoplasty using PHDPE were enrolled. PHDPE sheets were used for diverse purposes such as septal extension graft, spreader graft, columellar strut or dorsal augmentation graft. After a long-term follow-up period (mean [± SD] 39.5±27.8 months; range six to 101 months), postoperative aesthetic outcome was evaluated objectively (by independent surgeons) and subjectively (patient self-report). Complications related to PHDPE were estimated through review of medical records.
RESULTS: The most common use of the PHDPE graft was for septal extension (n=80 [42.6%]) and spreader graft (n=58 [30.9%]). Results of aesthetic evaluation by surgeons were excellent in 61 cases (40.4%), good in 54 (35.8%) and fair in 34 (22.5%). According to patient self-report, 100 were 'satisfied' (66.2%) and 36 rated their new profile as 'better than the preoperative profile' (23.8%). Complications were reported in six cases (4.0% [five cases of extrusion and one case of infection]). All complications were resolved after the surgical removal of PHDPE sheets under local anesthesia.
CONCLUSION: The present study demonstrated that PHDPE could be used in functional primary rhinoplasty with excellent long-term aesthetic results and safety.

Entities:  

Keywords:  Aesthetics; Polyethylenes; Postoperative complications; Rhinoplasty

Year:  2014        PMID: 25152641      PMCID: PMC4128427     

Source DB:  PubMed          Journal:  Plast Surg (Oakv)        ISSN: 2292-5503            Impact factor:   0.947


  19 in total

1.  An unusual complication of a Medpor implant in nasal reconstruction: a case report.

Authors:  Serdar Oztürk; Mustafa Sengezer; Usnsal Coskun; Fatih Zor
Journal:  Aesthetic Plast Surg       Date:  2002 Nov-Dec       Impact factor: 2.326

2.  Nasal augmentation using Gore-Tex. A 10-year experience.

Authors:  M S Godin; S R Waldman; C M Johnson
Journal:  Arch Facial Plast Surg       Date:  1999 Apr-Jun

3.  The use of high-density porous polyethylene as a custom-made nasal spreader graft.

Authors:  Ali Gürlek; Mehmet Celik; Alpay Fariz; Ayşe Ersöz-Oztürk; Ahmet T Eren; Göktekin Tenekeci
Journal:  Aesthetic Plast Surg       Date:  2006 Jan-Feb       Impact factor: 2.326

4.  Augmentation rhinoplasty with combined use of Medpor graft and irradiated homograft rib cartilage in saddle nose deformity.

Authors:  Ebrahim Razmpa; Babak Saedi; Farshid Mahbobi
Journal:  Arch Iran Med       Date:  2012-04       Impact factor: 1.354

5.  Clinical experience with the Medpor porous polyethylene implant.

Authors:  T Wellisz
Journal:  Aesthetic Plast Surg       Date:  1993       Impact factor: 2.326

6.  Custom porous polyethylene implants for large-scale pediatric skull reconstruction: early outcomes.

Authors:  Alexander Y Lin; Christopher R Kinsella; S Alex Rottgers; Darren M Smith; Lorelei J Grunwaldt; Gregory M Cooper; Joseph E Losee
Journal:  J Craniofac Surg       Date:  2012-01       Impact factor: 1.046

7.  Facial skeletal reconstruction using porous polyethylene implants.

Authors:  Michael J Yaremchuk
Journal:  Plast Reconstr Surg       Date:  2003-05       Impact factor: 4.730

8.  Clinical and histologic response of subcutaneous expanded polytetrafluoroethylene (Gore-Tex) and porous high-density polyethylene (Medpor) implants to acute and early infection.

Authors:  A P Sclafani; J R Thomas; A J Cox; M H Cooper
Journal:  Arch Otolaryngol Head Neck Surg       Date:  1997-03

9.  Orbital reconstruction using porous polyethylene sheets.

Authors:  P A Rubin; J R Bilyk; J W Shore
Journal:  Ophthalmology       Date:  1994-10       Impact factor: 12.079

10.  Use of Medpor porous polyethylene implants in 140 patients with facial fractures.

Authors:  J J Romano; N T Iliff; P N Manson
Journal:  J Craniofac Surg       Date:  1993-07       Impact factor: 1.046

View more
  1 in total

1.  Surface Modification of Polymers for Tissue Engineering Applications: Arginine Acts as a Sticky Protein Equivalent for Viable Cell Accommodation.

Authors:  Poulomi Sengupta; Bhagavatula L V Prasad
Journal:  ACS Omega       Date:  2018-04-16
  1 in total