Calibration of blood pressure data after replacement of the standard mercury sphygmomanometer by an oscillometric device and concurrent change of cuffs.

Hannelore K Neuhauser1, Ute Ellert, Michael Thamm, Carolin Adler.   

Abstract

Oscillometric blood pressure (BP) measurement devices are increasingly replacing standard mercury sphygmomanometers and generalizability of validation studies to other environments, for example, national survey environments, is assumed. We compared BP measurements according to two highly standardized German national survey BP protocols: a standard mercury sphygmomanometer and an oscillometric device, Datascope Accutorr Plus, each with specific manufacturer-provided cuffs and cuff-selection rules. A sample of 105 adults were subjected to alternate same-arm BP measurements according to the principles of the International Protocol revision 2010 for the validation of BP-measuring devices in adults of the European Society of Hypertension. In all, 315 BP measurement pairs were obtained. The mean systolic blood pressure (SBP) and diastolic blood pressure (DBP) were higher by the standard mercury old protocol and increased with BP, age, and pulse pressure, and were associated with the ratios of the cuff width to the arm circumference. The mean systolic difference (datascope new protocol-standard mercury old protocol) in participants with old protocol: for SBP<120 was -3.5 ± 4.9 mmHg (n=162), for SBP 120-139 (n=108) was -6.4 ± 5.8 mmHg, and for SBP ≥ 140 (n=45) was -11.9 ± 7.2 mmHg. For DBP<80/80-89/≥ 90 in 230/67/18 participants, the differences were -1.9 ± 5.0/-6.8 ± 5.9/-7.6 ± 5.2 mmHg. A calibration formula for SBP derived from linear regression modeling includes SBP, sex, age, pulse pressure, and the difference in the cuff-width to arm-circumference ratios for the two devices (for DBP without age). Our study suggests that even in a highly standardized national survey environment, reported agreement from validation studies may not be replicable and comparisons in the specific clinical or research setting can be useful before replacing the mercury device completely.

Entities:  

Mesh:

Year:  2015        PMID: 25144600     DOI: 10.1097/MBP.0000000000000081

Source DB:  PubMed          Journal:  Blood Press Monit        ISSN: 1359-5237            Impact factor:   1.444


  9 in total

1.  Hypertension in Germany.

Authors:  Hannelore Neuhauser; Claudia Diederichs; Heiner Boeing; Stephan B Felix; Claus Jünger; Roberto Lorbeer; Christine Meisinger; Annette Peters; Henry Völzke; Cornelia Weikert; Philipp Wild; Marcus Dörr
Journal:  Dtsch Arztebl Int       Date:  2016-12-02       Impact factor: 5.594

2.  Hypertension prevalence, awareness, treatment and control in Germany 1998 and 2008-11.

Authors:  H K Neuhauser; C Adler; A S Rosario; C Diederichs; U Ellert
Journal:  J Hum Hypertens       Date:  2014-10-02       Impact factor: 3.012

3.  The persisting gender gap in hypertension management and control in Germany: 1998 and 2008-2011.

Authors:  Giselle Sarganas; Hannelore K Neuhauser
Journal:  Hypertens Res       Date:  2016-01-28       Impact factor: 3.872

4.  Untreated, Uncontrolled, and Apparent Resistant Hypertension: Results of the German Health Examination Survey 2008-2011.

Authors:  Giselle Sarganas; Hannelore K Neuhauser
Journal:  J Clin Hypertens (Greenwich)       Date:  2016-08-02       Impact factor: 3.738

5.  Change in the association of body mass index and systolic blood pressure in Germany - national cross-sectional surveys 1998 and 2008-2011.

Authors:  Carolin Adler; Angelika Schaffrath Rosario; Claudia Diederichs; Hannelore K Neuhauser
Journal:  BMC Public Health       Date:  2015-07-25       Impact factor: 3.295

6.  Changes in diabetes care indicators: findings from German National Health Interview and Examination Surveys 1997-1999 and 2008-2011.

Authors:  Yong Du; Christin Heidemann; Angelika Schaffrath Rosario; Amanda Buttery; Rebecca Paprott; Hannelore Neuhauser; Thea Riedel; Andrea Icks; Christa Scheidt-Nave
Journal:  BMJ Open Diabetes Res Care       Date:  2015-11-19

7.  Metabolic Health in Relation to Body Size: Changes in Prevalence over Time between 1997-99 and 2008-11 in Germany.

Authors:  Julia Truthmann; Gert B M Mensink; Anja Bosy-Westphal; Christa Scheidt-Nave; Anja Schienkiewitz
Journal:  PLoS One       Date:  2016-11-23       Impact factor: 3.240

8.  Validation of the RisingSun RS-651 Blood Pressure Monitor Based on Auscultation in Adults According to the ANSI/AAMI/ISO 81060-2:2013 Standard.

Authors:  Jin She; Xizhou Guan; Yanyong Liu; Haiyan Xiang
Journal:  J Clin Hypertens (Greenwich)       Date:  2016-06-07       Impact factor: 3.738

9.  Body fat distribution and risk of incident ischemic stroke in men and women aged 50 to 74 years from the general population. The KORA Augsburg cohort study.

Authors:  Karl Zahn; Jakob Linseisen; Margit Heier; Annette Peters; Barbara Thorand; Franziska Nairz; Christa Meisinger
Journal:  PLoS One       Date:  2018-02-05       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.