| Literature DB >> 25141206 |
Andrea Sayuri Silveira Dias Terada1, Luiz Antonio Ferreira da Silva2, Rodrigo Galo3, Aline de Azevedo3, Raquel Fernanda Gerlach3, Ricardo Henrique Alves da Silva3.
Abstract
OBJECTIVE: The present study evaluated the use of a reagent to stabilize the DNA extracted from human dental tissues stored under different temperature conditions and time intervals.Entities:
Mesh:
Substances:
Year: 2014 PMID: 25141206 PMCID: PMC4126830 DOI: 10.1590/1678-775720130683
Source DB: PubMed Journal: J Appl Oral Sci ISSN: 1678-7757 Impact factor: 2.698
Description of experimental groups (n=5)
| Room temperature (24 to 37ºC) | |||||||
|---|---|---|---|---|---|---|---|
| AllprotectTM | No product | AllprotectTM | No product | AllprotectTM | No product | AllprotectTM | No product |
| AllprotectTM | No product | AllprotectTM | No product | AllprotectTM | No product | AllprotectTM | No product |
Mean and standard deviation of the quantification of genomic DNA by real-time PCR in the group of intact teeth, samples 1-80 (ng/μL)
| Days | Intacttooth | |||
|---|---|---|---|---|
| Allprotect | No product | |||
| 4-8ºC | 23-34ºC | 4-8ºC | 23-34ºC | |
| 1 | 1,064.62±461.64aA | 481.62±52.87aA | 921.12±204.95aA | 577.06±279.95aA |
| 7 | 1,067.90±290.18aA | 598.59±372.29aA | 418.08±161.08aA | 756.42±343.70aA |
| 30 | 297.49±98.57aA | 1,592.52±616.95aA | 886.14±473.76aA | 7.26±3.23bB |
| 180 | 1,003.77±428.06abA | 2,524.82±854.32aA | 504.63±274.24bcA | 20.57±10.48cB |
(Different lowercase letters indicate statistically significant differences between columns; different uppercase lettersindicate statistically significant differences between lines)
Mean and standard deviation of the quantification of genomic DNA by real-time PCR in the group of dental pulp, samples 81-160 (ng/μL)
| Days | Dental pulp | |||
|---|---|---|---|---|
| All protect | No product | |||
| 4-8ºC | 23-34ºC | 4-8ºC | 23-34ºC | |
| 1 | 394.77±116.57aA | 1,110.83±467.40aA | 604.28±231.91aA | 1,130.88±189.15aA |
| 7 | 1,417.17±356.73aA | 1,345.13±516.23aA | 844.94±341.35aA | 379.41±190.53aA |
| 30 | 787.97±325.76aA | 1,279.79±686.13aA | 1,457.28±738.56aA | 1,025.09±685.44aA |
| 180 | 3,416.48±1826.41aA | 1,533.69±519.53abA | 2,260.70±454.02aA | 82.33±66.08bA |
(Different lowercase letters indicate statistically significant differences between columns; different uppercase letters indicate statistically significant differences between lines)
Figure 2Image of the Gene Mapper™ ID software (Applied Biosystems, USA) for the STR analysis in three differents samples