| Literature DB >> 25140081 |
Jorge H Villafañe1, Kristin Valdes2.
Abstract
[Purpose] The aim of this study was to examine the test-retest reliability of pinch strength testing in elderly subjects with thumb CMC OA.Entities:
Keywords: Pinch strength; Reliability; Test-retest
Year: 2014 PMID: 25140081 PMCID: PMC4135222 DOI: 10.1589/jpts.26.993
Source DB: PubMed Journal: J Phys Ther Sci ISSN: 0915-5287
Test and retest values, and index of relative, and absolute reliability of pinch strength in subjects with thumb CMC OA*
| Pinch strength | Side | Test | Retest | Bias | ICC | 95% LOA (kg) | SEM | |
|---|---|---|---|---|---|---|---|---|
| (kg) | (kg) | (kg) | (95% CI) | Lower | Upper | (kg) | ||
| Tip pinch | Affected right hand | 2.44 ±1.13 | 2.49 ±1.21 | 0.05 | 0.93 (0.85; 0.97) | −0.80 | 0.90 | 0.06 |
| Contralateral left hand | 1.94 ±0.73 | 1.93 ±0.74 | 0.01 | 0.91 (0.81; 0.96) | −0.61 | 0.62 | 0.05 | |
| Tripod pinch | Affected right hand | 3.09 ±1.4 | 3.07 ±1.46 | 0.03 | 0.96 (0.92; 0.98) | −0.76 | 0.81 | 0.04 |
| Contralateral left hand | 2.58 ±1.05 | 2.61 ±1.04 | −0.03 | 0.92 (0.83; 0.96) | −0.85 | 0.85 | 0.06 | |
| Key pinch | Affected right hand | 3.11 ±1.05 | 3.10 ±1.06 | 0.02 | 0.99 (0.97; 0.99) | −0.35 | 0.38 | 0.01 |
| Contralateral left hand | 2.88 ±0.62 | 2.81 ±0.58 | 0.07 | 0.94 (0.87; 0.97) | −0.34 | 0.48 | 0.03 | |
* Data are expressed as means ± SD. Bias, difference between test and retest; ICC, intraclass correlation coefficient; 95% CI, 95% confidence interval; 95% LOA, 95% limits of agreement; SEM, standard error of measurement