| Literature DB >> 25135053 |
H Versteeg1, S S Pedersen, M H Mastenbroek, W K Redekop, J O Schwab, P Mabo, M Meine.
Abstract
BACKGROUND: Remote patient monitoring is a safe and effective alternative for the in-clinic follow-up of patients with cardiovascular implantable electronic devices (CIEDs). However, evidence on the patient perspective on remote monitoring is scarce and inconsistent.Entities:
Year: 2014 PMID: 25135053 PMCID: PMC4188843 DOI: 10.1007/s12471-014-0587-z
Source DB: PubMed Journal: Neth Heart J ISSN: 1568-5888 Impact factor: 2.380
Fig. 1Schematic representation of the study design
Patient-reported outcomes and psychological factors assessed in the study
| Construct | Questionnaire | T0 | T1 | T2 | T3 | T4 |
|---|---|---|---|---|---|---|
| Outcome measures | ||||||
| Health status | Kansas City Cardiomyopathy Questionnaire (KCCQ) | x | x | x | x | x |
| Device acceptance | Florida Patient Acceptance Survey (FPAS) | x | x | x | x | x |
| Satisfaction with care | Visual analogue scale (0–100) | x | x | x | x | x |
| Satisfaction with remote monitoringa | Purpose-designed questionnaire | x | x | x | x | |
| Cost-effectiveness: QALY | Euroqol 5D (EQ-5D) + VAS scale | x | x | x | x | x |
| Cost-effectiveness: productivity and health care utilisation | Purpose-designed questionnaire | x | x | x | x | |
| Psychological variables | ||||||
| ICD concerns | ICD Patient Concerns Questionnaire (ICDC) | x | x | x | x | |
| ICD expectationsb | Expectations regarding ICD | x | ||||
| Illness perception | Illness Perceptions Questionnaire (IPQ) | x | x | |||
| Anxiety symptoms | Generalised Anxiety Disorder (GAD-7) | x | x | x | ||
| Depressive symptoms | Patient Health Questionnaire (PHQ-9) | x | x | x | ||
| Type D personality | Type D Scale (DS14) | x | ||||
| Self-care behaviour | European Heart Failure Self Care Behaviour Scale (EHFScBS) | x | x | x | ||
T0 = Baseline; T1 = 3 months; T2 = 6 months; T3 = 12 months; T4 = 24 months
ICD implantable cardioverter defibrillator; QALY quality-adjusted life year; VAS visual analogue scale
aPatients in RPM group only
bDutch patients only