Literature DB >> 25126446

Teleoperation System with Hybrid Pneumatic-Piezoelectric Actuation for MRI-Guided Needle Insertion with Haptic Feedback.

Weijian Shang1, Hao Su1, Gang Li1, Gregory S Fischer1.   

Abstract

This paper presents a surgical master-slave tele-operation system for percutaneous interventional procedures under continuous magnetic resonance imaging (MRI) guidance. This system consists of a piezoelectrically actuated slave robot for needle placement with integrated fiber optic force sensor utilizing Fabry-Perot interferometry (FPI) sensing principle. The sensor flexure is optimized and embedded to the slave robot for measuring needle insertion force. A novel, compact opto-mechanical FPI sensor interface is integrated into an MRI robot control system. By leveraging the complementary features of pneumatic and piezoelectric actuation, a pneumatically actuated haptic master robot is also developed to render force associated with needle placement interventions to the clinician. An aluminum load cell is implemented and calibrated to close the impedance control loop of the master robot. A force-position control algorithm is developed to control the hybrid actuated system. Teleoperated needle insertion is demonstrated under live MR imaging, where the slave robot resides in the scanner bore and the user manipulates the master beside the patient outside the bore. Force and position tracking results of the master-slave robot are demonstrated to validate the tracking performance of the integrated system. It has a position tracking error of 0.318mm and sine wave force tracking error of 2.227N.

Entities:  

Keywords:  Fabry-Perot interferometry; MRI-compatible robot; haptics; image-guided needle placement; percutaneous therapy; pneumatic control; teleoperation

Year:  2013        PMID: 25126446      PMCID: PMC4128939          DOI: 10.1109/IROS.2013.6696942

Source DB:  PubMed          Journal:  Rep U S        ISSN: 2153-0858


  20 in total

1.  Towards MRI guided surgical manipulator.

Authors:  K Chinzei; K Miller
Journal:  Med Sci Monit       Date:  2001 Jan-Feb

2.  MRI-Compatible Pneumatic Robot for Transperineal Prostate Needle Placement.

Authors:  Gregory S Fischer; Iulian Iordachita; Csaba Csoma; Junichi Tokuda; Simon P Dimaio; Clare M Tempany; Nobuhiko Hata; Gabor Fichtinger
Journal:  IEEE ASME Trans Mechatron       Date:  2008-06-01       Impact factor: 5.303

3.  Real-Time Estimation of 3-D Needle Shape and Deflection for MRI-Guided Interventions.

Authors:  Yong-Lae Park; Santhi Elayaperumal; Bruce Daniel; Seok Chang Ryu; Mihye Shin; Joan Savall; Richard J Black; Behzad Moslehi; Mark R Cutkosky
Journal:  IEEE ASME Trans Mechatron       Date:  2010-12       Impact factor: 5.303

Review 4.  Magnetic resonance-compatible robotic and mechatronics systems for image-guided interventions and rehabilitation: a review study.

Authors:  Nikolaos V Tsekos; Azadeh Khanicheh; Eftychios Christoforou; Constantinos Mavroidis
Journal:  Annu Rev Biomed Eng       Date:  2007       Impact factor: 9.590

5.  The feasibility of MR-image guided prostate biopsy using piezoceramic motors inside or near to the magnet isocentre.

Authors:  Haytham Elhawary; Aleksander Zivanovic; Marc Rea; Brian Davies; Collin Besant; Donald McRobbie; Nandita de Souza; Ian Young; Michael Lampérth
Journal:  Med Image Comput Comput Assist Interv       Date:  2006

Review 6.  Opportunities and challenges in MR-compatible robotics: reviewing the history, mechatronic components, and future directions of this technology.

Authors:  Roger Gassert; Eienne Burdet; Kiyoyuki Chinzei
Journal:  IEEE Eng Med Biol Mag       Date:  2008 May-Jun

Review 7.  Compatible instrumentation for intraoperative MRI: expanding resources.

Authors:  F A Jolesz; P R Morrison; S J Koran; R J Kelley; S G Hushek; R W Newman; M P Fried; A Melzer; R M Seibel; H Jalahej
Journal:  J Magn Reson Imaging       Date:  1998 Jan-Feb       Impact factor: 4.813

8.  Development of a Pneumatic Robot for MRI-guided Transperineal Prostate Biopsy and Brachytherapy: New Approaches.

Authors:  Sang-Eun Song; Nathan B Cho; Gregory Fischer; Nobuhito Hata; Clare Tempany; Gabor Fichtinger; Iulian Iordachita
Journal:  IEEE Int Conf Robot Autom       Date:  2010-07-15

9.  "MRI Stealth" robot for prostate interventions.

Authors:  Dan Stoianovici; Danny Song; Doru Petrisor; Daniel Ursu; Dumitru Mazilu; Michael Muntener; Michael Mutener; Michael Schar; Alexandru Patriciu
Journal:  Minim Invasive Ther Allied Technol       Date:  2007       Impact factor: 2.442

10.  Design of a Teleoperated Needle Steering System for MRI-guided Prostate Interventions.

Authors:  Reza Seifabadi; Iulian Iordachita; Gabor Fichtinger
Journal:  Proc IEEE RAS EMBS Int Conf Biomed Robot Biomechatron       Date:  2012-12-31
View more
  8 in total

1.  An MRI-Guided Telesurgery System Using a Fabry-Perot Interferometry Force Sensor and a Pneumatic Haptic Device.

Authors:  Hao Su; Weijian Shang; Gang Li; Niravkumar Patel; Gregory S Fischer
Journal:  Ann Biomed Eng       Date:  2017-04-26       Impact factor: 3.934

2.  System Integration and Preliminary Clinical Evaluation of a Robotic System for MRI-Guided Transperineal Prostate Biopsy.

Authors:  Niravkumar A Patel; Gang Li; Weijian Shang; Marek Wartenberg; Tamas Heffter; Everette C Burdette; Iulian Iordachita; Junichi Tokuda; Nobuhiko Hata; Clare M Tempany; Gregory S Fischer
Journal:  J Med Robot Res       Date:  2018-05-15

3.  Fiber Optic Force Sensors for MRI-Guided Interventions and Rehabilitation: A Review.

Authors:  Hao Su; Iulian I Iordachita; Junichi Tokuda; Nobuhiko Hata; Xuan Liu; Reza Seifabadi; Sheng Xu; Bradford Wood; Gregory S Fischer
Journal:  IEEE Sens J       Date:  2017-01-17       Impact factor: 3.301

4.  State of the Art and Future Opportunities in MRI-Guided Robot-Assisted Surgery and Interventions.

Authors:  Hao Su; Ka-Wai Kwok; Kevin Cleary; Iulian Iordachita; M Cenk Cavusoglu; Jaydev P Desai; Gregory S Fischer
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2022-05-03       Impact factor: 14.910

5.  Development of an MRI-Compatible Needle Driver for In-Bore Prostate Biopsy.

Authors:  Meng Li; Berk Gonenc; Kiyoung Kim; Weijian Shang; Iulian Iordachita
Journal:  Proc Int Conf Adv Robot       Date:  2015-09-10

6.  MR-Compatible Haptic Display of Membrane Puncture in Robot-Assisted Needle Procedures.

Authors:  Amy Kyungwon Han; Jung Hwa Bae; Katerina C Gregoriou; Christopher J Ploch; Roger E Goldman; Gary H Glover; Bruce L Daniel; Mark R Cutkosky
Journal:  IEEE Trans Haptics       Date:  2018-03-19       Impact factor: 2.487

7.  A Cylindrical Grip Type of Tactile Device Using Magneto-Responsive Materials Integrated with Surgical Robot Console: Design and Analysis.

Authors:  Yu-Jin Park; Eun-Sang Lee; Seung-Bok Choi
Journal:  Sensors (Basel)       Date:  2022-01-30       Impact factor: 3.576

8.  A Novel Remote-Controlled Vascular Interventional Robotic System Based on Hollow Ultrasonic Motor.

Authors:  Qing Lu; Zhijun Sun; Jialiang Zhang; Jiacheng Zhang; Juju Zheng; Feng Qian
Journal:  Micromachines (Basel)       Date:  2022-03-04       Impact factor: 2.891

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.