A comparison of mid-forehead and axillary temperatures in newborn intensive care.

J Robertson-Smith1, F T McCaffrey1, R Sayers2, S Williams2, B J Taylor2.   

Abstract

OBJECTIVE: To evaluate accuracy of mid-forehead (MFH) thermometry compared with digital axilla (DAT) temperatures in infants in newborn intensive care. STUDY
DESIGN: A comparative study of MFH and DAT temperatures of newborn infants receiving tertiary-level intensive care. All admissions were considered and the following exclusion criteria applied: 'in extremis', hypoxic ischemic encephalopathy or non-English-speaking parents. Foot temperatures, infant and environmental variables were measured. RESULT: In all, 783 readings were obtained in 100 infants with a birth weight range 515 to 4885 g (mean 2152 g). The between-person correlation was 0.30 (P < 0.001) and the within-person correlation was 0.52 (P < 0.001). Bland-Altman plots showed wide 95% confidence intervals in the differences between MFH and DAT measurements (-0.87 to 1.16 °C). Differences were affected by infant variables measured. MFH more accurately predicted DAT measurements in smaller neonates and were less accurate in neonates requiring Bubble Continuous Positive Airway Pressure (CPAP).
CONCLUSION: MFH thermometry is not able to replace DAT temperature recording in the newborn intensive care.

Entities:  

Mesh:

Year:  2014        PMID: 25118720     DOI: 10.1038/jp.2014.148

Source DB:  PubMed          Journal:  J Perinatol        ISSN: 0743-8346            Impact factor:   2.521


  9 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

Review 2.  Goals and options in keeping preterm babies warm.

Authors:  A J Lyon; Y Freer
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2010-05-20       Impact factor: 5.747

3.  Comparison between rectal and infrared skin temperature in the newborn.

Authors:  Mario De Curtis; Flaminia Calzolari; Alessandra Marciano; Viviana Cardilli; Gianvincenzo Barba
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2008-01       Impact factor: 5.747

Review 4.  Thermoregulation and axillary temperature measurements in neonates: a review of the literature.

Authors:  E B Keeling
Journal:  Matern Child Nurs J       Date:  1992 Fall-Winter

5.  A comparison of different methods of temperature measurements in sick newborns.

Authors:  Sinan Uslu; Hamus Ozdemir; Ali Bulbul; Serdar Comert; Fatih Bolat; Emrah Can; Asiye Nuhoglu
Journal:  J Trop Pediatr       Date:  2011-01-18       Impact factor: 1.165

Review 6.  Temperature measurement in the preterm and term neonate: a review of the literature.

Authors:  Jacqueline Smith; Gary Alcock; Kim Usher
Journal:  Neonatal Netw       Date:  2013 Jan-Feb

7.  Temperature control in very low birthweight infants during first five days of life.

Authors:  A J Lyon; M E Pikaar; P Badger; N McIntosh
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1997-01       Impact factor: 5.747

8.  Accuracy of infrared thermometers in very low birth weight infants and impact on newborn behavioural states.

Authors:  Melanie Jarvis; Katelyn J Guy; Kai König
Journal:  J Paediatr Child Health       Date:  2013-04-25       Impact factor: 1.954

9.  Comparison of temporal artery, mid-forehead skin and axillary temperature recordings in preterm infants <1500 g of birthweight.

Authors:  Ridvan Duran; Ulfet Vatansever; Betül Acunaş; Necdet Süt
Journal:  J Paediatr Child Health       Date:  2009 Jul-Aug       Impact factor: 1.954

  9 in total
  3 in total

1.  Performance of a non-contact infrared thermometer in healthy newborns.

Authors:  Sara Sollai; Carlo Dani; Elettra Berti; Claudia Fancelli; Luisa Galli; Maurizio de Martino; Elena Chiappini
Journal:  BMJ Open       Date:  2016-03-16       Impact factor: 2.692

2.  Time Trends and Predictors of Abnormal Postoperative Body Temperature in Infants Transported to the Intensive Care Unit.

Authors:  Hedwig Schroeck; Angela K Lyden; Wendy L Benedict; Satya Krishna Ramachandran
Journal:  Anesthesiol Res Pract       Date:  2016-09-29

3.  Usefulness of Non-Contact Infrared Thermometer for Early Neonatal Period Using Bland-Altman Analysis.

Authors:  Saori Sugawara; George Imataka; Shigemi Yoshihara
Journal:  Iran J Public Health       Date:  2020-02       Impact factor: 1.429

  3 in total