A comparison of different methods of temperature measurements in sick newborns.

Sinan Uslu1, Hamus Ozdemir, Ali Bulbul, Serdar Comert, Fatih Bolat, Emrah Can, Asiye Nuhoglu.   

Abstract

We aimed to compare the accuracy of digital axillary thermometer (DAT), rectal glass mercury thermometer (RGMT), infrared tympanic thermometer (ITT) and infrared forehead skin thermometer (IFST) measurements with traditional axillary glass mercury thermometer (AGMT) for intermittent temperature measurement in sick newborns. A prospective, descriptive and comparative study in which five different types of thermometer readings were performed sequentially for 3 days. A total of 1989 measurements were collected from 663 newborns. DAT and ITT measurements correlated most closely to AGMT (r = 0.94). The correlation coefficent for IFST and RGMT were 0.74 and 0.87, respectively. The mean differences for DAT, ITT, RGMT and IFST were +0.02°C, +0.03°C, +0.25°C and +0.55°C, respectively. There were not any clinical differences (defined as a mean difference of 0.2°C) between both mean AGMT&DAT and AGMT&ITT measurements. Our study suggests that tympanic thermometer measurement could be used as an acceptable and practical method for sick newborn in neonatal units.

Mesh:

Year:  2011        PMID: 21245075     DOI: 10.1093/tropej/fmq120

Source DB:  PubMed          Journal:  J Trop Pediatr        ISSN: 0142-6338            Impact factor:   1.165


  8 in total

1.  A comparison of different methods of temperature measurement by mothers and physicians in healthy newborns.

Authors:  Mehmet Yekta Oncel; Kadir Serafettin Tekgunduz; Ramazan Ozdemir; Erhan Calisici; Sevilay Karahan; Omer Erdeve; Serife Suna Oguz; Ugur Dilmen
Journal:  Indian J Pediatr       Date:  2012-06-02       Impact factor: 1.967

2.  Method Comparison (Agreement) Studies: Myths and Rationale.

Authors:  Ajay G Phatak; Somashekhar M Nimbalkar
Journal:  J Clin Diagn Res       Date:  2017-01-01

3.  A comparison of mid-forehead and axillary temperatures in newborn intensive care.

Authors:  J Robertson-Smith; F T McCaffrey; R Sayers; S Williams; B J Taylor
Journal:  J Perinatol       Date:  2014-08-14       Impact factor: 2.521

4.  A comparison of tympanic and rectal temperatures in term Nigerian neonates.

Authors:  Chika O Duru; Felix O Akinbami; Adebola E Orimadegun
Journal:  BMC Pediatr       Date:  2012-06-25       Impact factor: 2.125

5.  Performance of a non-contact infrared thermometer in healthy newborns.

Authors:  Sara Sollai; Carlo Dani; Elettra Berti; Claudia Fancelli; Luisa Galli; Maurizio de Martino; Elena Chiappini
Journal:  BMJ Open       Date:  2016-03-16       Impact factor: 2.692

6.  Association of Immediate Postoperative Temperature in the Surgical Intensive Care Unit with 1-Year Mortality: Retrospective Analysis Using Digital Axillary Thermometers.

Authors:  Jiwook Kim; Tak Kyu Oh; Jaebong Lee; Saeyeon Kim; In-Ae Song
Journal:  Acute Crit Care       Date:  2019-01-09

7.  Axillary and rectal thermometry in the newborn: do they agree?

Authors:  Lama Charafeddine; Hani Tamim; Habiba Hassouna; Randa Akel; Mona Nabulsi
Journal:  BMC Res Notes       Date:  2014-08-31

8.  Studying the Accuracy and Function of Different Thermometry Techniques for Measuring Body Temperature.

Authors:  Aaron James Mah; Leili Ghazi Zadeh; Mahta Khoshnam Tehrani; Shahbaz Askari; Amir H Gandjbakhche; Babak Shadgan
Journal:  Biology (Basel)       Date:  2021-12-15
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.