Literature DB >> 25099476

Vascular response to drug-eluting stent with biodegradable vs. durable polymer. Optical coherence tomography substudy of the NEXT.

Takashi Kubo1, Takashi Akasaka, Ken Kozuma, Kazuo Kimura, Tetsuya Fusazaki, Hiroyuki Okura, Toshiro Shinke, Yasushi Ino, Takao Hasegawa, Hiroaki Takashima, Itaru Takamisawa, Hiroshi Yamaguchi, Keiichi Igarashi, Kazushige Kadota, Kengo Tanabe, Yoshihisa Nakagawa, Toshiya Muramatsu, Yoshihiro Morino, Takeshi Kimura.   

Abstract

BACKGROUND: The aim of the present study was to compare vascular healing response between everolimus-eluting stent (EES) and biolimus-eluting stent (BES) using optical coherence tomography (OCT). METHODS AND
RESULTS: In the NOBORI Biolimus-Eluting Versus XIENCE V/PROMUS Everolimus-Eluting Stent Trial (NEXT), a formal OCT substudy investigated 91 patients (55 EES-treated lesions in 48 patients and 51 BES-treated lesions in 43 patients) with 8-12 months follow-up imaging at 18 centers. A total of 980 frames with 8,996 struts in EES and 907 frames with 8,745 struts in BES were analyzed. Mean neointima thickness in EES and BES was 105±82μm and 91±80μm, respectively (P<0.001). With regard to stent-treated lesions, the percentage of struts not covered by neointima (3±7% vs. 9±10%, P<0.001) and the frequency of stent-treated lesions with any uncovered struts (n=28, 51% vs. n=42, 82%; P<0.001) were significantly lower in EES compared with BES. In addition, the percentage of malapposed struts (0.2±0.8% vs. 1.3±2.8%, P=0.006) and the frequency of stent-treated lesions with any malapposed struts (n=6, 11% vs. n=14, 27%; P=0.028) were significantly lower in EES compared with BES.
CONCLUSIONS: Incomplete vascular healing characterized by the presence of struts not covered by neointima and malapposed struts was less common in EES compared with BES.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25099476     DOI: 10.1253/circj.cj-14-0337

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  11 in total

1.  Assessment of vascular response after drug-eluting stents implantation in patients with diabetes mellitus: an optical coherence tomography sub-study of the J-DESsERT.

Authors:  Takashi Kubo; Takashi Akasaka; Takashi Tanimoto; Masamichi Takano; Yoshitane Seino; Kenya Nasu; Tomonori Itoh; Kyoichi Mizuno; Hiroyuki Okura; Toshiro Shinke; Jun-Ichi Kotani; Shigenori Ito; Hiroyoshi Yokoi; Toshiya Muramatsu; Masato Nakamura; Shinsuke Nanto
Journal:  Heart Vessels       Date:  2015-01-29       Impact factor: 2.037

2.  Comparison of long-term in-stent vascular response between abluminal groove-filled biodegradable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent: 3-year OCT follow-up from the TARGET I trial.

Authors:  Bo Xu; Yao-Jun Zhang; Zhong-Wei Sun; Shu-Bin Qiao; Shao-Liang Chen; Rui-Yan Zhang; Dao-Rong Pan; Si Pang; Qi Zhang; Liang Xu; Yue-Jin Yang; Martin B Leon; Run-Lin Gao
Journal:  Int J Cardiovasc Imaging       Date:  2015-07-26       Impact factor: 2.357

3.  Very early neointimal coverage of new biodegradable polymer drug-eluting stent compared with durable polymer everolimus-eluting stent evaluated by optical frequency domain imaging.

Authors:  Norihiro Kobayashi; Yoshiaki Ito; Masahiro Yamawaki; Motoharu Araki; Tsuyoshi Sakai; Yasunari Sakamoto; Shinsuke Mori; Masakazu Tsutsumi; Masahiro Nauchi; Yohsuke Honda; Takahiro Tokuda; Kenji Makino; Shigemitsu Shirai; Keisuke Hirano
Journal:  Int J Cardiovasc Imaging       Date:  2017-11-20       Impact factor: 2.357

4.  Two-year clinical outcomes of zotarolimus- and everolimus-eluting durable-polymer-coated stents versus biolimus-eluting biodegradable-polymer-coated stent in patients with acute myocardial infarction with dyslipidemia after percutaneous coronary intervention: data from the KAMIR.

Authors:  Yong Hoon Kim; Ae-Young Her; Myung Ho Jeong; Byeong-Keuk Kim; Sung-Jin Hong; Dong-Ho Shin; Jung-Sun Kim; Young-Guk Ko; Donghoon Choi; Myeong-Ki Hong; Yangsoo Jang
Journal:  Heart Vessels       Date:  2018-08-30       Impact factor: 2.037

5.  Intravascular imaging comparison of two metallic limus-eluting stents abluminally coated with biodegradable polymers: IVUS and OCT results of the DESTINY trial.

Authors:  J Ribamar Costa; Daniel Chamié; Alexandre A C Abizaid; Expedito Ribeiro; George C Meireles; Maurício Prudente; Carlos A Campos; Juliana P Castro; Ricardo Costa; Pedro A Lemos
Journal:  Int J Cardiovasc Imaging       Date:  2016-10-06       Impact factor: 2.357

6.  Current State of Bioabsorbable Polymer-Coated Drug-Eluting Stents.

Authors:  Abhilash Akinapelli; Jack P Chen; Kristine Roy; Joseph Donnelly; Keith Dawkins; Barbara Huibregtse; Dongming Hou
Journal:  Curr Cardiol Rev       Date:  2017

7.  Vascular response to biolimus A-9 eluting stent in patients with shorter and prolonged dual antiplatelet therapy: optical coherence tomography sub-study of the NIPPON trial.

Authors:  Koji Kuroda; Toshiro Shinke; Hiromasa Otake; Hiroto Kinutani; Raisuke Iijima; Junya Ako; Hisayuki Okada; Yoshiaki Ito; Kenji Ando; Hitoshi Anzai; Hiroyuki Tanaka; Yasunori Ueda; Shin Takiuchi; Yasunori Nishida; Hiroshi Ohira; Katsuhiro Kawaguchi; Makoto Kadotani; Hiroyuki Niinuma; Kazuto Omiya; Takashi Morita; Kan Zen; Yoshinori Yasaka; Kenji Inoue; Sugao Ishiwata; Masahiko Ochiai; Toshimitsu Hamasaki; Kazushi Urasawa; Toru Kataoka; Minoru Yoshiyama; Kenshi Fujii; Takumi Inoue; Masahito Kawata; Hiroyoshi Yokoi; Masato Nakamura
Journal:  Heart Vessels       Date:  2018-02-20       Impact factor: 2.037

8.  Optical coherence tomography assessment of efficacy of thrombus aspiration in patients undergoing a primary percutaneous coronary intervention for acute ST-elevation myocardial infarction.

Authors:  Tomoyuki Yamaguchi; Takashi Kubo; Yasushi Ino; Yoshiki Matsuo; Yasutsugu Shiono; Takashi Yamano; Akira Taruya; Tsuyoshi Nishiguchi; Aiko Shimokado; Makoto Orii; Atsushi Tanaka; Takeshi Hozumi; Takashi Akasaka
Journal:  Coron Artery Dis       Date:  2015-11       Impact factor: 1.439

9.  Vascular response to bioresorbable polymer sirolimus-eluting stent vs. permanent polymer everolimus-eluting stent at 9-month follow-up: an optical coherence tomography sub-study from the CENTURY II trial.

Authors:  Shoichi Kuramitsu; Yoshio Kazuno; Shinjo Sonoda; Takenori Domei; Hiroyuki Jinnouchi; Kyohei Yamaji; Yoshimitsu Soga; Shinichi Shirai; Kenji Ando; Shigeru Saito
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2015-09-01       Impact factor: 6.875

10.  Impact of current smoking on 2-year clinical outcomes between durable-polymer-coated stents and biodegradable-polymer-coated stents in acute myocardial infarction after successful percutaneous coronary intervention: Data from the KAMIR.

Authors:  Yong Hoon Kim; Ae-Young Her; Myung Ho Jeong; Byeong-Keuk Kim; Sung-Jin Hong; Dong-Ho Shin; Jung-Sun Kim; Young-Guk Ko; Donghoon Choi; Myeong-Ki Hong; Yangsoo Jang
Journal:  PLoS One       Date:  2018-10-05       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.