Literature DB >> 25087158

Nicking enzyme and graphene oxide-based dual signal amplification for ultrasensitive aptamer-based fluorescence polarization assays.

Yong Huang1, Xiaoqian Liu2, Liangliang Zhang3, Kun Hu3, Shulin Zhao4, Baizong Fang5, Zhen-Feng Chen3, Hong Liang6.   

Abstract

In this work, two different configurations for novel amplified fluorescence polarization (FP) aptasensors based on nicking enzyme signal amplification (NESA) and graphene oxide (GO) enhancement have been developed for ultrasensitive and selective detection of biomolecules in homogeneous solution. One approach involves the aptamer-target binding induced the stable hybridization between an aptamer probe and a fluorophore-labeled DNA probe linked to GO, and forms a nicking site-containing duplex DNA region due to the enhancement of base stacking. The second analytical method involves the target induced the assembly of two aptamer subunits into an aptamer-target complex, and then hybridizes with a fluorophore-labeled DNA probe linked to GO, forming a nicking site-containing duplex DNA region. The formation of the duplex DNA region in both methods triggers the NESA process, resulting in the release of many short DNA fragments carrying the fluorophore from GO, generating a significant decrease of the FP value that provides the readout signal for the amplified sensing process. By using the NESA coupled GO enhancement path, the sensitivity of the developed aptasensors can be significantly improved by four orders of magnitude over traditional aptamer-based homogeneous assays. Moreover, these aptasensors also exhibit high specificity for target molecules, which are capable of detecting target molecule in biological samples. Considering these qualities, the proposed FP aptasensors based NESA and GO enhancement can be expected to provide an ultrasensitive platform for amplified analysis of target molecules.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Amplified analysis; Aptasensors; Fluorescence polarization; Graphene oxide; Nicking enzyme

Mesh:

Substances:

Year:  2014        PMID: 25087158     DOI: 10.1016/j.bios.2014.07.036

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  7 in total

Review 1.  Trends in the Design and Development of Specific Aptamers Against Peptides and Proteins.

Authors:  Maryam Tabarzad; Marzieh Jafari
Journal:  Protein J       Date:  2016-04       Impact factor: 2.371

Review 2.  Aptamers in analytics.

Authors:  Muslum Ilgu; Marit Nilsen-Hamilton
Journal:  Analyst       Date:  2016-03-07       Impact factor: 4.616

Review 3.  A review on graphene-based nanocomposites for electrochemical and fluorescent biosensors.

Authors:  Siva Kumar Krishnan; Eric Singh; Pragya Singh; Meyya Meyyappan; Hari Singh Nalwa
Journal:  RSC Adv       Date:  2019-03-18       Impact factor: 4.036

Review 4.  Fluorescence anisotropy (polarization): from drug screening to precision medicine.

Authors:  Hairong Zhang; Qian Wu; Mikhail Y Berezin
Journal:  Expert Opin Drug Discov       Date:  2015-08-03       Impact factor: 6.098

Review 5.  Fluorescence Polarization-Based Bioassays: New Horizons.

Authors:  Olga D Hendrickson; Nadezhda A Taranova; Anatoly V Zherdev; Boris B Dzantiev; Sergei A Eremin
Journal:  Sensors (Basel)       Date:  2020-12-12       Impact factor: 3.576

Review 6.  Recent advances in fluorescence anisotropy/polarization signal amplification.

Authors:  Xue Xiao; Shujun Zhen
Journal:  RSC Adv       Date:  2022-02-23       Impact factor: 3.361

Review 7.  Graphene-Based Biosensors for Detection of Biomarkers.

Authors:  Yunlong Bai; Tailin Xu; Xueji Zhang
Journal:  Micromachines (Basel)       Date:  2020-01-03       Impact factor: 2.891

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.