Pilot study of radiation dose reduction for pediatric head CT in evaluation of ventricular size.

S Gabriel1, L J Eckel2, D R DeLone3, K N Krecke3, P H Luetmer3, C H McCollough3, J G Fletcher3, L Yu3.   

Abstract

BACKGROUND AND
PURPOSE: CT is a ubiquitous, efficient, and cost-effective method to evaluate pediatric ventricular size, particularly in patients with CSF shunt diversion who often need emergent imaging. We therefore sought to determine the minimum dose output or CT dose index required to produce clinically acceptable examinations.
MATERIALS AND METHODS: Using a validated noise insertion method and CT projection data from 22 patients, standard pediatric head CT images were reconstructed with weighted filtered back-projection and sinogram-affirmed iterative reconstruction corresponding to routine, 25%, and 10% dose. Reconstructed images were then evaluated by 3 neuroradiologists (blinded to dose and reconstruction method) for ventricular size, diagnostic confidence, image quality, evidence of hemorrhage, and shunt tip location, and compared with the reference standard.
RESULTS: There was no significant difference in the ventricular size ranking, and the sensitivity for moderate to severe hydrocephalus was 100%. There was no significant difference between the full-dose level and the ventricular size rankings at the 25% or the 10% dose level for either reconstruction kernel (P > .979). Diagnostic confidence was maintained across doses and kernel. Hemorrhage was more difficult to identify as image quality degraded as dose decreased but was still seen in a majority of cases. Shunts were identified by all readers across all doses and reconstruction methods.
CONCLUSIONS: CT images having dose reductions of 90% relative to routine head CT examinations provide acceptable image quality to address the specific clinical task of evaluating ventricular size.
© 2014 by American Journal of Neuroradiology.

Entities:  

Mesh:

Year:  2014        PMID: 25082822      PMCID: PMC7965300          DOI: 10.3174/ajnr.A4056

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  16 in total

1.  Development of the Spitz-Holter valve in Philadelphia.

Authors:  J A Boockvar; W Loudon; L N Sutton
Journal:  J Neurosurg       Date:  2001-07       Impact factor: 5.115

2.  Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique.

Authors:  Priyanka Prakash; Mannudeep K Kalra; Avinash K Kambadakone; Homer Pien; Jiang Hsieh; Michael A Blake; Dushyant V Sahani
Journal:  Invest Radiol       Date:  2010-04       Impact factor: 6.016

3.  Individualized kV selection and tube current reduction in excretory phase computed tomography urography: potential for radiation dose reduction and the contribution of iterative reconstruction to image quality.

Authors:  Adam T Froemming; Akira Kawashima; Naoki Takahashi; Robert P Hartman; Mark A Nathan; Rickey E Carter; Lifeng Yu; Shuai Leng; Hiroki Kagoshima; Cynthia H McCollough; Joel G Fletcher
Journal:  J Comput Assist Tomogr       Date:  2013 Jul-Aug       Impact factor: 1.826

4.  Signs and symptoms of cerebrospinal fluid shunt malfunction in the pediatric emergency department.

Authors:  Tommy Y Kim; Gail Stewart; Marcus Voth; James A Moynihan; Lance Brown
Journal:  Pediatr Emerg Care       Date:  2006-01       Impact factor: 1.454

5.  Defending the use of medical imaging.

Authors:  Cynthia H McCollough
Journal:  Health Phys       Date:  2011-03       Impact factor: 1.316

6.  Estimated risks of radiation-induced fatal cancer from pediatric CT.

Authors:  D Brenner; C Elliston; E Hall; W Berdon
Journal:  AJR Am J Roentgenol       Date:  2001-02       Impact factor: 3.959

7.  Development and validation of a practical lower-dose-simulation tool for optimizing computed tomography scan protocols.

Authors:  Lifeng Yu; Maria Shiung; Dayna Jondal; Cynthia H McCollough
Journal:  J Comput Assist Tomogr       Date:  2012 Jul-Aug       Impact factor: 1.826

8.  Revision rate of pediatric ventriculoperitoneal shunts after 15 years.

Authors:  Jonathan J Stone; Corey T Walker; Maxwell Jacobson; Valerie Phillips; Howard J Silberstein
Journal:  J Neurosurg Pediatr       Date:  2012-10-26       Impact factor: 2.375

9.  Rapid sequence magnetic resonance imaging in the assessment of children with hydrocephalus.

Authors:  Brent R O'Neill; Sumit Pruthi; Harmanjeet Bains; Ryan Robison; Keiko Weir; Jeff Ojemann; Richard Ellenbogen; Anthony Avellino; Samuel R Browd
Journal:  World Neurosurg       Date:  2012-10-27       Impact factor: 2.104

10.  A low radiation computed tomography protocol for monitoring shunted hydrocephalus.

Authors:  Kuriakose J George; Deb Roy
Journal:  Surg Neurol Int       Date:  2012-09-13
View more
  6 in total

1.  Low-Dose CT for Craniosynostosis: Preserving Diagnostic Benefit with Substantial Radiation Dose Reduction.

Authors:  J C Montoya; L J Eckel; D R DeLone; A L Kotsenas; F E Diehn; L Yu; A C Bartley; R E Carter; C H McCollough; J G Fletcher
Journal:  AJNR Am J Neuroradiol       Date:  2017-02-09       Impact factor: 3.825

2.  Targeted head CT reduction for pediatric patients with hydrocephalus and traumatic brain injury: academic center institutional experience as an example of opportunities for further improvement.

Authors:  Allie Harbert; Weston Northam; Scott Elton; Carolyn Quinsey
Journal:  Childs Nerv Syst       Date:  2019-11-06       Impact factor: 1.475

3.  Evaluation of Lower-Dose Spiral Head CT for Detection of Intracranial Findings Causing Neurologic Deficits.

Authors:  J G Fletcher; D R DeLone; A L Kotsenas; N G Campeau; V T Lehman; L Yu; S Leng; D R Holmes; P K Edwards; M P Johnson; G J Michalak; R E Carter; C H McCollough
Journal:  AJNR Am J Neuroradiol       Date:  2019-10-24       Impact factor: 3.825

4.  Observer Performance with Varying Radiation Dose and Reconstruction Methods for Detection of Hepatic Metastases.

Authors:  Joel G Fletcher; Jeff L Fidler; Sudhakar K Venkatesh; David M Hough; Naoki Takahashi; Lifeng Yu; Matthew Johnson; Shuai Leng; David R Holmes; Rickey Carter; Cynthia H McCollough
Journal:  Radiology       Date:  2018-09-11       Impact factor: 11.105

5.  Observer Performance for Detection of Pulmonary Nodules at Chest CT over a Large Range of Radiation Dose Levels.

Authors:  Joel G Fletcher; David L Levin; Anne-Marie G Sykes; Rebecca M Lindell; Darin B White; Ronald S Kuzo; Vighnesh Suresh; Lifeng Yu; Shuai Leng; David R Holmes; Akitoshi Inoue; Matthew P Johnson; Rickey E Carter; Cynthia H McCollough
Journal:  Radiology       Date:  2020-09-29       Impact factor: 11.105

6.  Radiation Dose Reduction in Pediatric Body CT Using Iterative Reconstruction and a Novel Image-Based Denoising Method.

Authors:  Lifeng Yu; Joel G Fletcher; Maria Shiung; Kristen B Thomas; Jane M Matsumoto; Shannon N Zingula; Cynthia H McCollough
Journal:  AJR Am J Roentgenol       Date:  2015-11       Impact factor: 3.959

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.