Literature DB >> 25078089

On the lorentzian versus Gaussian character of time-domain spin-echo signals from the brain as sampled by means of gradient-echoes: Implications for quantitative transverse relaxation studies.

Robert V Mulkern1, Mukund Balasubramanian1, Dimitrios Mitsouras2.   

Abstract

PURPOSE: To determine whether Lorentzian or Gaussian intra-voxel frequency distributions are better suited for modeling data acquired with gradient-echo sampling of single spin-echoes for the simultaneous characterization of irreversible and reversible relaxation rates. Clinical studies (e.g., of brain iron deposition) using such acquisition schemes have typically assumed Lorentzian distributions. THEORY AND METHODS: Theoretical expressions of the time-domain spin-echo signal for intra-voxel Lorentzian and Gaussian distributions were used to fit data from a human brain scanned at both 1.5 Tesla (T) and 3T, resulting in maps of irreversible and reversible relaxation rates for each model. The relative merits of the Lorentzian versus Gaussian model were compared by means of quality of fit considerations.
RESULTS: Lorentzian fits were equivalent to Gaussian fits primarily in regions of the brain where irreversible relaxation dominated. In the multiple brain regions where reversible relaxation effects become prominent, however, Gaussian fits were clearly superior.
CONCLUSION: The widespread assumption that a Lorentzian distribution is suitable for quantitative transverse relaxation studies of the brain should be reconsidered, particularly at 3T and higher field strengths as reversible relaxation effects become more prominent. Gaussian distributions offer alternate fits of experimental data that should prove quite useful in general. Magn Reson Med 74:51-62, 2015.
© 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  Gaussian; Lorentzian; brain iron; frequency distributions; transverse relaxation

Year:  2014        PMID: 25078089      PMCID: PMC4312272          DOI: 10.1002/mrm.25365

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  24 in total

1.  Brain iron deposition in Parkinson's disease imaged using the PRIME magnetic resonance sequence.

Authors:  J M Graham; M N Paley; R A Grünewald; N Hoggard; P D Griffiths
Journal:  Brain       Date:  2000-12       Impact factor: 13.501

2.  Applications of stimulated echo correction to multicomponent T2 analysis.

Authors:  Thomas Prasloski; Burkhard Mädler; Qing-San Xiang; Alex MacKay; Craig Jones
Journal:  Magn Reson Med       Date:  2011-10-19       Impact factor: 4.668

3.  Determination of transverse relaxation rate for estimating iron deposits in central nervous system.

Authors:  Tachio Hikita; Kazuo Abe; Saburo Sakoda; Hisashi Tanaka; Kenya Murase; Norihiko Fujita
Journal:  Neurosci Res       Date:  2005-01       Impact factor: 3.304

4.  Magnetic field correlation imaging.

Authors:  Jens H Jensen; Ramesh Chandra; Anita Ramani; Hanzhang Lu; Glyn Johnson; Sang-Pil Lee; Kyle Kaczynski; Joseph A Helpern
Journal:  Magn Reson Med       Date:  2006-06       Impact factor: 4.668

5.  Method for image-based measurement of the reversible and irreversible contribution to the transverse-relaxation rate.

Authors:  J Ma; F W Wehrli
Journal:  J Magn Reson B       Date:  1996-04

6.  An MRI method for measuring T2 in the presence of static and RF magnetic field inhomogeneities.

Authors:  D A Yablonskiy; E M Haacke
Journal:  Magn Reson Med       Date:  1997-06       Impact factor: 4.668

7.  Periaqueductal gray matter dysfunction in migraine: cause or the burden of illness?

Authors:  K M Welch; V Nagesh; S K Aurora; N Gelman
Journal:  Headache       Date:  2001 Jul-Aug       Impact factor: 5.887

8.  In vivo visualization of myelin water in brain by magnetic resonance.

Authors:  A MacKay; K Whittall; J Adler; D Li; D Paty; D Graeb
Journal:  Magn Reson Med       Date:  1994-06       Impact factor: 4.668

9.  Assessment of relative brain iron concentrations using T2-weighted and T2*-weighted MRI at 3 Tesla.

Authors:  R J Ordidge; J M Gorell; J C Deniau; R A Knight; J A Helpern
Journal:  Magn Reson Med       Date:  1994-09       Impact factor: 4.668

10.  Determinants of brain iron in multiple sclerosis: a quantitative 3T MRI study.

Authors:  M Khalil; C Langkammer; S Ropele; K Petrovic; M Wallner-Blazek; M Loitfelder; M Jehna; G Bachmaier; R Schmidt; C Enzinger; S Fuchs; F Fazekas
Journal:  Neurology       Date:  2011-10-05       Impact factor: 9.910

View more
  7 in total

1.  Characterization of gradient echo signal decays in healthy and cancerous prostate at 3T improves with a Gaussian augmentation of the mono-exponential (GAME) model.

Authors:  Pelin Aksit Ciris; Mukund Balasubramanian; Ravi T Seethamraju; Junichi Tokuda; Jonathan Scalera; Tobias Penzkofer; Fiona M Fennessy; Clare M Tempany-Afdhal; Kemal Tuncali; Robert V Mulkern
Journal:  NMR Biomed       Date:  2016-05-31       Impact factor: 4.044

2.  Dual-pathway multi-echo sequence for simultaneous frequency and T2 mapping.

Authors:  Cheng-Chieh Cheng; Chang-Sheng Mei; Jeffrey Duryea; Hsiao-Wen Chung; Tzu-Cheng Chao; Lawrence P Panych; Bruno Madore
Journal:  J Magn Reson       Date:  2016-02-04       Impact factor: 2.229

3.  Information theoretic evaluation of Lorentzian, Gaussian, Voigt, and symmetric alpha-stable models of reversible transverse relaxation in cervical cancer in vivo at 3 T.

Authors:  Pelin Ciris
Journal:  MAGMA       Date:  2022-08-04       Impact factor: 2.533

4.  Characterizing gradient echo signal decays in gynecologic cancers at 3T using a Gaussian augmentation of the monoexponential (GAME) model.

Authors:  Pelin A Ciris; Mukund Balasubramanian; Antonio L Damato; Ravi T Seethamraju; Clare M Tempany-Afdhal; Robert V Mulkern; Akila N Viswanathan
Journal:  J Magn Reson Imaging       Date:  2016-03-12       Impact factor: 4.813

5.  Spectroscopic sampling of the left side of long-TE spin echoes: a free lunch?

Authors:  Robert V Mulkern; Mukund Balasubramanian
Journal:  MAGMA       Date:  2017-09-07       Impact factor: 2.310

6.  Design of spectral-spatial phase prewinding pulses and their use in small-tip fast recovery steady-state imaging.

Authors:  Sydney N Williams; Jon-Fredrik Nielsen; Jeffrey A Fessler; Douglas C Noll
Journal:  Magn Reson Med       Date:  2017-07-03       Impact factor: 4.668

7.  In vivo measurements of irreversible and reversible transverse relaxation rates in human basal ganglia at 7 T: making inferences about the microscopic and mesoscopic structure of iron and calcification deposits.

Authors:  Mukund Balasubramanian; Jonathan R Polimeni; Robert V Mulkern
Journal:  NMR Biomed       Date:  2019-07-19       Impact factor: 4.044

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.