| Literature DB >> 25069952 |
Yi Tian Wang, Terry P Haines, Paul Ritchie, Craig Walker, Teri A Ansell, Danielle T Ryan, Phaik-Sim Lim, Sanjiv Vij, Rebecca Acs, Nigel Fealy, Elizabeth H Skinner.
Abstract
INTRODUCTION: Despite studies demonstrating benefit, patients with femoral vascular catheters placed for continuous renal replacement therapy are frequently restricted from mobilization. No researchers have reported filter pressures during mobilization, and it is unknown whether mobilization is safe or affects filter lifespan. Our objective in this study was to test the safety and feasibility of mobilization in this population.Entities:
Mesh:
Year: 2014 PMID: 25069952 PMCID: PMC4262200 DOI: 10.1186/cc14001
Source DB: PubMed Journal: Crit Care ISSN: 1364-8535 Impact factor: 9.097
Figure 1Flowchart of participants through the study. IJ: Internal jugular; SC: Subclavian.
Demographic and clinical details of the sample at the time of the intervention
| Variable | Baseline group ( | Intervention group ( | Femoral ( | Nonfemoral ( |
|---|---|---|---|---|
| Age, yr | 63.6 (13.6) | 63.7 (14.8) | 63.7 (14.1) | 63.6 (17.2) |
| Sex, % male | 79% | 61% | 65% | 50% |
| BMI | 28.0 (5.1) | 29.3 (10.6) | 31.7 (11.2) | 23.9 (7.0) |
| Diagnosis, % | ||||
| Cardiogenic shock/cardiac | 26% | 33% | 30% | 40% |
| Septic shock/sepsis/MOF | 47% | 43% | 44% | 40% |
| Renal/metabolic/electrolyte | 21% | 15% | 17% | 10% |
| Haemorrhagic shock/haematoma | 0% | 9% | 9% | 10% |
| Vascular surgery | 5% | 0% | 0% | 0% |
| APACHE II score | – | 26.1 (7.2) | 25.7 (6.8) | 26.9 (8.2) |
| APACHE III score | 98.3 (26.9) | 93.8 (24.9) | 91.1 (23.1) | 100.0 (29.1) |
| ICU length of stay, days | 10.2 (6.9) | 15.0 (10.0) | 15.4 (9.3) | 14.1 (11.8) |
| MV, % | 74% | 76% | 74% | 80% |
| MV hours, median (IQR) | 78 (0 to 153) | 76 (0 to 267) | 89 (0 to 295) | 63 (30 to 190) |
| Siteb, % | ||||
| Femoral | 63% | 70% | 100% | 0% |
| Internal jugular | 37% | 21% | 0% | 70% |
| Subclavian | 0% | 9% | 0% | 30% |
| Catheter typec, | ||||
| Dolphin Protect | 13 (68%) | 19 (58%) | 13 (57%) | 6 (55%) |
| Niagara™ | 5 (26%) | 9 (27%) | 7 (30%) | 2 (18%) |
| Arrow-Howes™ | 1 (5%) | 5 (15%) | 3 (13%) | 1 (9%) |
| Intervention filter type, % | ||||
| Prismaflex ST100 | N/A | 94% | 91% | 100% |
| Intervention filter anticoagulation, % | ||||
| Heparin | N/A | 27% | 26% | 30% |
| Citrate | N/A | 6% | 4% | 10% |
| Saline | N/A | 0% | 0% | 0% |
| Regional circuit | N/A | 52 | 48% | 60% |
| Other | N/A | 3% | 4% | 0% |
| Nil | N/A | 12% | 17% | 0% |
| FBE on intervention filter, median (IQR) | ||||
| Hb, g/dl | N/A | 89 (85 to 94) | 88 (81 to 91) | 93 (90 to 103) |
| Platelets, 103 U/L | N/A | 125 (60 to 200) | 121 (59 to 174) | 179 (60 to 252) |
| INR | N/A | 1.1 (1.1 to 1.4) | 1.2 (1.1 to 1.4) | 1.1 (1.1 to 1.3) |
| aPTT | N/A | 39 (34 to 52) | 40 (34 to 55) | 34 (33 to 44) |
| RASS, median (IQR) | N/A | -1 (-4 to 0) | -2 (-4 to 0) | -1 (-1 to 0) |
| CAM-ICU positive, % | N/A | 42% | 39% | 50% |
| Hospital LOS in days, median (IQR) | 23 (9 to 31) | 31 (21 to 57) | 29 (21 to 57) | 37 (15 to 57) |
| Hospital mortality, % | 42% | 15% | 17% | 10% |
aaPTT, Activated thromboplastin time; BMI: Body mass index; CAM-ICU: Confusion Assessment Method for the ICU; FBE: Full blood examination; Hb: Haemoglobin; ICU: Intensive care unit; INR: International normalized ratio; IQR: Interquartile range; LOS: Length of stay; MOF: Multiorgan failure; MV: Mechanical ventilation; N/A: Not applicable; RASS: Richmond Agitation–Sedation Scale. bFemoral (14 in right, 9 in left), intrajugular (6 in right, 1 in left) and subclavian (3 in left, 1 in right). cDolphin Protect (13-French gauge, 25 cm; Gambro, Hechingen, Germany), Niagara™ (13.5-French gauge; Bard Access Systems, Salt Lake City, UT, USA), Arrow-Howes™ triple-lumen (13-French, 20 cm; Teleflex, Research Triangle Park, NC, USA). Data are mean (SD) unless otherwise specified. Percentages may not add up to 100% due to rounding.
Figure 2Comparison of femoral filter life. Preintervention filters are those that patients had prior to recruitment and intervention. Intervention filters are those in place during the time the intervention took place. Postintervention filters are those placed after the intervention filter.
Subgroup and sensitivity analyses of filter life and possible confounders
| Group | Factors | Regression coefficient (robust 95% CI) |
|
|---|---|---|---|
| Baseline ( | INR | 0.8 (-1.4 to 3.0) | 0.44 |
| aPTT | 0.1 (-0.3 to 0.5) | 0.63 | |
| Platelets | 0.0 (0.0 to 0.1) | 0.09 | |
| Positional changes | 1.2 (-0.4 to 2.9) | 0.13 | |
| APACHE III | -0.1 (-0.3 to 0.0) | 0.09 | |
| Overall cohort (MOVE intervention) ( | MOVE intervention | 13.8 (5.0 to 22.6) | 0.003b |
| Overall subgroup and sensitivity analyses | Passive movements | 20.0 (5.4 to 34.6) | 0.01b |
| SOEOB | 5.8 (-10.7 to 22.3) | 0.46 | |
| MOS | 18.3 (-1.3 to 37.9) | 0.06 | |
| INR | 9.3 (-2.0 to 20.5) | 0.10 | |
| aPTT | 0.0 (-0.2 to 0.2) | 0.86 | |
| Platelets | 0.0 (-0.1 to 0.0) | 0.10 | |
| Positional changes | 2.0 (0.6 to 3.5) | 0.007b | |
| APACHE III | 0.1 (0.0 to 0.3) | 0.02b | |
| Alarms | -3.1 (-5.0 to -1.2) | 0.003b | |
| Femoral subgroup ( | MOVE intervention | 15.7 (4.6 to 26.9) | 0.008b |
| Femoral subgroup and sensitivity analyses | Passive movements | 20.0 (5.4 to 34.6) | 0.01b |
| SOEOB | 8.5 (-20.6 to 37.7) | 0.51 | |
| MOS | 20.5 (-19.9 to 60.9) | 0.16 | |
| INR | 7.6 (-4.9 to 20.0) | 0.22 | |
| aPTT | -0.1 (-0.2 to 0.1) | 0.38 | |
| Platelets | 0.0 (-0.1 to 0.0) | 0.29 | |
| Positional changes | 2.0 (0.5 to 3.6) | 0.01b | |
| APACHE III | 0.6 (-0.1 to 0.2) | 0.42 | |
| Alarms | -7.4 (-13.0 to -1.8) | 0.01b | |
| Nonfemoral subgroup ( | MOVE intervention | 9.2 (-6.0 to 24.4) | 0.20 |
| Nonfemoral subgroup and sensitivity analyses | Passive movements | N/A | – |
| SOEOB | 1.0 (-12.8 to 14.8) | 0.86 | |
| MOS | 20.6 (-23.3 to 64.4) | 0.23 | |
| INR | 26.4 (7.5 to 45.3) | 0.01b | |
| aPTT | 0.5 (0.1 to 0.9) | 0.03b | |
| Platelets | -0.1 (-0.1 to 0.0) | 0.08 | |
| Positional changes | 1.9 (-1.7 to 5.4) | 0.27 | |
| APACHE III | 0.2 (0.0 to 0.5) | 0.05 | |
| Alarms | -2.3 (-4.6 to 0.0) | 0.05 |
APACHE III: Acute Physiology and Chronic Health Evaluation III; aPTT: Activated partial thromboplastin time; CI: Confidence interval; INR: International normalized ratio; MOS: Marching on the spot; MOVE: Movement on vascular catheter evaluation intervention; N/A: Not applicable; SOEOB: Sitting on edge of bed. Electively ceased filters were excluded from analysis. Twenty-three (17.2%) of one hundred thirty-four femoral filters and fourteen (23.0%) of sixty-one nonfemoral filters were excluded from the filter life analyses, as they were electively ceased. Units of measurement for filter life are hours. Position changes are measured as number per day. Alarms are the number of alarms during the intervention session. bStatistically significant difference.