| Literature DB >> 25068604 |
Kathleen Hutchinson Marron1, Brittany Sproat2, Danielle Ross3, Sarah Wagner4, Helaine Alessio5.
Abstract
This study examined the relationship between hearing levels, otoacoustic emission levels and listening habits related to the use of personal listening devices (PLDs) in adults with varying health-related fitness. Duration of PLD use was estimated and volume level was directly measured. Biomarkers of health-related fitness were co-factored into the analyses. 115 subjects ages 18-84 participated in this study. Subjects were divided into two sub-groups; PLD users and non-PLD users. Both groups completed audiological and health-related fitness tests. Due to the mismatch in the mean age of the PLD user versus the non-PLD user groups, age-adjusted statistics were performed to determine factors that contributed to hearing levels. Age was the most significant predictor of hearing levels across listening and health-related fitness variables. PLD user status did not impact hearing measures, yet PLD users who listened less than 8 hours per week with intensities of less than 80 dBA were found to have better hearing. Other variables found to be associated with hearing levels included: years listening to PLD, number of noise environments and use of ear protection. Finally, a healthy waist-to-hip ratio was a significant predictor of better hearing, while body mass index approached, but did not reach statistical significance.Entities:
Mesh:
Year: 2014 PMID: 25068604 PMCID: PMC4143820 DOI: 10.3390/ijerph110807592
Source DB: PubMed Journal: Int J Environ Res Public Health ISSN: 1660-4601 Impact factor: 3.390
Participant demographics by gender and user-status.
| PLD Status | N | # of Females | # of Males | Mean Age | Pure Tone Wideband Mean | Pure Tone HF-band Mean |
|---|---|---|---|---|---|---|
| PLD-user | 72 | 42 | 33 | 40.71 | 11.98 | 14.91 |
| Non-PLD user | 43 | 30 | 10 | 52.78 | 15.23 | 23.39 |
Traditional audiometric frequency means by age and frequency.
| Age Group | Traditional Audiometry Mean | High-Frequency Band Means |
|---|---|---|
| < 50 | 10.97 dB HL | 13.76 dB HL |
| 50 + | 14.59 dB HL | 22.81 dB HL |
Variables contributing to wideband pure tone means for PLD users.
| Traditional Audiometric Frequency Means | ||
|---|---|---|
| Parameter | Pr > | | |
| Age | 8.49 | <0.0001 |
| Total Number of Noise History Environments | −2.01 | 0.0502 |
| Absence of Tinnitus | −1.70 | 0.0958 |
| Family History of Hearing Loss | 1.95 | 0.0572 |
| Years Listening to Device | −2.31 | 0.0253 |
| Hours Listening to Device/Week | 2.65 | 0.0111 |
Listening variables contributing to high-frequency band means for PLD users.
| High-Frequency Band Means (4 to 8k Hz) | ||
|---|---|---|
| Parameter | Pr > | | |
| Age | 9.77 | <0.0001 |
| Total Number of Noise Environments | −2.14 | 0.0372 |
| Years Listening to Device | −2.49 | 0.0164 |
| Hours Listening to Device/Week | 1.78 | 0.0822 |
PLD listening levels in silence.
| Silence Harmful | Gender | N | Wide band Mean(dB HL) | HF-band Mean(dB HL) | Mean Listening Intensity(dBA) | SD | Min Volume (dBA) | Max Volume (dBA) |
|---|---|---|---|---|---|---|---|---|
| No | Female | 26 | 8.79 | 9.82 | 57.316 | 12.420 | 37.463 | 75.909 |
| Male | 17 | 12.08 | 17.50 | 63.469 | 9.757 | 46.260 | 76.870 | |
| Yes | Female | 2 | 18.57 | 27.50 | 90.130 | 9.381 | 83.497 | 96.763 |
| Male | 6 | 14.76 | 17.22 | 82.984 | 2.334 | 80.097 | 85.800 |
PLD listening levels in noise.
| Noise Harmful | Gender | N | PT Wide band Mean(dB HL) | HF-band Mean(dB HL) | Mean Listening Intensity(dBA) | SD | Min Volume (dBA) | Max Volume (dBA) |
|---|---|---|---|---|---|---|---|---|
| No | Female | 17 | 9.76 | 11.44 | 70.867 | 9.843 | 40.462 | 79.795 |
| Male | 11 | 12.83 | 17.77 | 73.354 | 7.080 | 54.381 | 79.487 | |
| Yes | Female | 11 | 9.07 | 10.52 | 87.149 | 4.640 | 81.371 | 95.070 |
| Male | 12 | 12.73 | 17.11 | 87.675 | 6.630 | 81.556 | 101.856 |
Mean measures of health-related variables across participants.
| Variable | Mean | SD | Minimum | Maximum |
|---|---|---|---|---|
| BMI (kg/m2) | 25.21 | 4.62 | 18.46 | 38.92 |
| Waist-to-hip ratio | 0.84 | 0.09 | 0.60 | 1.09 |
| VO2 Max (ml/kg/min) | 34.54 | 8.76 | 14.80 | 63.90 |
| Physical Activity (steps/day) | 8714 | 3702 | 3185 | 18,257 |
Mean measures of health related variables and hearing according to age.
| Age | Variable | Mean | SD | Minimum | Maximum |
|---|---|---|---|---|---|
| 50 + | BMI | 26.30 | 5.10 | 18.7 | 38.1 |
| Waist-to-hip | 0.87 | 0.08 | 0.7 | 1.1 | |
| VO2 Max | 30.90 | 5.40 | 17.6 | 42.7 | |
| Pure Tone Mean 0.25–8 kHz | 14.60 | 8.50 | −10.0 | 75.0 | |
| Pure Tone Mean 4–8 kHz | 22.80 | 6.00 | −10.0 | 75.0 | |
| ≤50 | BMI | 24.39 | 4.06 | 18.5 | 38.9 |
| Waist-to-hip | 0.8 | 0.08 | 0.6 | 1.1 | |
| VO2 Max | 37.2 | 9.80 | 14.8 | 63.9 | |
| Pure tone Mean 0.25–8 kHz | 11.00 | 2.40 | −10.0 | 110.0 | |
| Pure tone Mean 4–8 kHz | 13.80 | .86 | −10.0 | 110.0 |