Literature DB >> 25053514

Substantial iodine volume load reduction in CT angiography with dual-energy imaging: insights from a pilot randomized study.

Patricia Carrascosa1, Carlos Capunay, Gaston A Rodriguez-Granillo, Alejandro Deviggiano, Javier Vallejos, Jonathon A Leipsic.   

Abstract

We explored whether dual-energy computed tomography (DECT) can allow a significant reduction in iodinated contrast volume during computed tomography angiography (CTA) without hampering image quality or assessibility. We prospectively randomized patients clinically referred to CTA to single energy computed tomography (SECT) with full iodine volume load (group A), DECT with 50 % iodine volume load (group B), DECT with 40 % iodine volume load (group C), and DECT with 30 % iodine volume load (group D); and compared image quality and assessibility. Eighty patients were enrolled and prospectively randomized. The mean age was 61.7 ± 15.0 years and 56 (71 %) patients were male. The demographical characteristics, body mass index, or mean radiation dose did not differ between groups. Significant reductions in total contrast volume were achieved in groups B, C, and D; with mean administrated contrast volumes of 90.3 ± 10.1, 39.5 ± 4.6, 28.3 ± 6.5, and 23.9 ± 6.0 mL, respectively, in groups A to D (p < 0.0001). With regard to image quality, no significant decrease in the Likert scale was observed with reductions of up to 60 % of the contrast volume (groups B and C). DECT at 50-60 keV in association with up to 60 % iodine load reduction, allowed similar signal density, image noise, and signal to noise ratio that SECT imaging with full iodine load. In this pilot, prospective, randomized study, dual energy CTA with up to 60 % iodine volume load reduction provided similar image quality and assessibility than full iodine load with conventional SECT imaging.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25053514     DOI: 10.1007/s10554-014-0501-1

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  14 in total

1.  Quantitative myocardial perfusion imaging using rapid kVp switch dual-energy CT: preliminary experience.

Authors:  Aaron So; Ting-Yim Lee; Yasuhiro Imai; Suresh Narayanan; Jiang Hsieh; John Kramer; Karen Procknow; Jonathon Leipsic; Troy Labounty; James Min
Journal:  J Cardiovasc Comput Tomogr       Date:  2011-10-25

Review 2.  Contrast nephropathy in azotemic diabetic patients undergoing coronary angiography.

Authors:  C L Manske; J M Sprafka; J T Strony; Y Wang
Journal:  Am J Med       Date:  1990-11       Impact factor: 4.965

Review 3.  Contrast-induced nephropathy: a clinical and evidence-based approach.

Authors:  Martin Tepel; Peter Aspelin; Norbert Lameire
Journal:  Circulation       Date:  2006-04-11       Impact factor: 29.690

4.  Ultra-low contrast volumes reduce rates of contrast-induced nephropathy in patients with chronic kidney disease undergoing coronary angiography.

Authors:  Garvan C Kane; Brendan J Doyle; Amir Lerman; Gregory W Barsness; Patricia J Best; Charanjit S Rihal
Journal:  J Am Coll Cardiol       Date:  2008-01-01       Impact factor: 24.094

5.  Contrast-to-noise ratio and low-contrast object resolution on full- and low-dose MDCT: SAFIRE versus filtered back projection in a low-contrast object phantom and in the liver.

Authors:  Mark E Baker; Frank Dong; Andrew Primak; Nancy A Obuchowski; David Einstein; Namita Gandhi; Brian R Herts; Andrei Purysko; Erick Remer; Neil Vachhani; Neil Vachani
Journal:  AJR Am J Roentgenol       Date:  2012-07       Impact factor: 3.959

6.  Optimization of contrast material delivery for dual-energy computed tomography pulmonary angiography in patients with suspected pulmonary embolism.

Authors:  John W Nance; Thomas Henzler; Mathias Meyer; Paul Apfaltrer; Margarita Braunagel; Radko Krissak; Uwe J Schoepf; Stefan O Schoenberg; Christian Fink
Journal:  Invest Radiol       Date:  2012-01       Impact factor: 6.016

7.  80-kV pulmonary CT angiography with 40 mL of iodinated contrast material in lean patients: comparison of vascular enhancement with iodixanol (320 mg I/mL)and iomeprol (400 mg I/mL).

Authors:  Lorenzo Faggioni; Emanuele Neri; Paola Sbragia; Rachele Pascale; Luigia D'Errico; Davide Caramella; Carlo Bartolozzi
Journal:  AJR Am J Roentgenol       Date:  2012-12       Impact factor: 3.959

8.  Incidence of contrast-induced nephropathy after contrast-enhanced computed tomography in the outpatient setting.

Authors:  Alice M Mitchell; Alan E Jones; James A Tumlin; Jeffrey A Kline
Journal:  Clin J Am Soc Nephrol       Date:  2009-12-03       Impact factor: 8.237

9.  Spectral optimization of chest CT angiography with reduced iodine load: experience in 80 patients evaluated with dual-source, dual-energy CT.

Authors:  Marie-Aurélie Delesalle; François Pontana; Alain Duhamel; Jean-Baptiste Faivre; Thomas Flohr; Nunzia Tacelli; Jacques Remy; Martine Remy-Jardin
Journal:  Radiology       Date:  2013-01-14       Impact factor: 11.105

10.  [Creatinine clearance and contrast nephropathy in patients with normal creatinine levels].

Authors:  José A de Agustín; Rocío Carda; María del C Manzano; Borja Ruiz-Mateos; Juan C García-Rubira; Antonio Fernández-Ortiz; Isidre Vilacosta; Carlos Macaya
Journal:  Rev Esp Cardiol       Date:  2007-07       Impact factor: 4.753

View more
  20 in total

1.  Evaluation of different keV-settings in dual-energy CT angiography of the aorta using advanced image-based virtual monoenergetic imaging.

Authors:  Martin Beeres; Jesko Trommer; Claudia Frellesen; Nour-Eldin A Nour-Eldin; Jan E Scholtz; Eva Herrmann; Thomas J Vogl; Julian L Wichmann
Journal:  Int J Cardiovasc Imaging       Date:  2015-08-02       Impact factor: 2.357

2.  Aortic CT angiography using the double region of interest timing bolus technique: feasibility of 80 kVp scanning in lean patients.

Authors:  Nobuo Tomizawa; Shingo Ito; Tastuya Nakao; Hiroaki Arakawa; Kodai Yamamoto; Shinichi Inoh; Takeshi Nojo; Sunao Nakamura
Journal:  Int J Cardiovasc Imaging       Date:  2019-07-02       Impact factor: 2.357

Review 3.  New Applications of Cardiac Computed Tomography: Dual-Energy, Spectral, and Molecular CT Imaging.

Authors:  Ibrahim Danad; Zahi A Fayad; Martin J Willemink; James K Min
Journal:  JACC Cardiovasc Imaging       Date:  2015-06

Review 4.  "How to" incorporate dual-energy imaging into a high volume abdominal imaging practice.

Authors:  Eric P Tamm; Ott Le; Xinming Liu; Rick R Layman; Dianna D Cody; Priya R Bhosale
Journal:  Abdom Radiol (NY)       Date:  2017-03

Review 5.  Cardiac CT Imaging of Plaque Vulnerability: Hype or Hope?

Authors:  Martin J Willemink; Tim Leiner; Pál Maurovich-Horvat
Journal:  Curr Cardiol Rep       Date:  2016-04       Impact factor: 2.931

Review 6.  Delayed enhancement cardiac computed tomography for the assessment of myocardial infarction: from bench to bedside.

Authors:  Gaston A Rodriguez-Granillo
Journal:  Cardiovasc Diagn Ther       Date:  2017-04

7.  Beam hardening artifact reduction using dual energy computed tomography: implications for myocardial perfusion studies.

Authors:  Gaston A Rodriguez-Granillo; Patricia Carrascosa; Silvina Cipriano; Macarena De Zan; Alejandro Deviggiano; Carlos Capunay; Ricardo C Cury
Journal:  Cardiovasc Diagn Ther       Date:  2015-02

8.  Advanced image-based virtual monoenergetic dual-energy CT angiography of the abdomen: optimization of kiloelectron volt settings to improve image contrast.

Authors:  Moritz H Albrecht; Jan-Erik Scholtz; Kristina Hüsers; Martin Beeres; Andreas M Bucher; Moritz Kaup; Simon S Martin; Sebastian Fischer; Boris Bodelle; Ralf W Bauer; Thomas Lehnert; Thomas J Vogl; Julian L Wichmann
Journal:  Eur Radiol       Date:  2015-09-03       Impact factor: 5.315

9.  Contrast media injection protocol optimization for dual-energy coronary CT angiography: results from a circulation phantom.

Authors:  Domenico De Santis; Damiano Caruso; U Joseph Schoepf; Marwen Eid; Moritz H Albrecht; Taylor M Duguay; Akos Varga-Szemes; Andrea Laghi; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2018-02-27       Impact factor: 5.315

10.  Feasibility of low-dose contrast media in run-off CT angiography on dual-layer spectral detector CT.

Authors:  Haiyan Ren; Yanhua Zhen; Zheng Gong; Chuanzhuo Wang; Zhihui Chang; Jiahe Zheng
Journal:  Quant Imaging Med Surg       Date:  2021-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.