Literature DB >> 25053371

Agreement of high definition oscillometry with direct arterial blood pressure measurement at different blood pressure ranges in horses under general anaesthesia.

Julia Tünsmeyer1, Klaus Hopster, Karsten Feige, Sabine Br Kästner.   

Abstract

OBJECTIVE: To determine the agreement of high definition oscillometry (HDO) with direct arterial blood pressure measurements in normotensive, hypotensive and hypertensive horses during general anaesthesia. STUDY
DESIGN: Experimental study. ANIMALS: Seven healthy warmblood horses, aged 3-11 years, weighing 470-565 kg.
METHODS: Measurements from a HDO device with the cuff placed around the base of the tail were compared with pressures measured invasively from the facial artery. High blood pressures were induced by intravenous (IV) administration of dobutamine (5 μg kg(-1) minute(-1)) over ten minutes followed by norepinephrine (0.1 mg kg(-1) IV) and low pressures by increasing the inspired fraction of isoflurane and administration of nitroglycerine (0.05 mg kg(-1) IV). For analysis three pressure levels were determined: high (MAP>110 mmHg), normal (60 mmHg<MAP<110 mmHg) and low (MAP< 60 mmHg). Bland-Altman analysis was used for comparison between non-invasive and invasive measurements.
RESULTS: A total of 245 paired measurements of systolic (SAP), mean (MAP) and diastolic (DAP) pressures were obtained. The HDO device underestimated blood pressure at hypertensive and normotensive levels and overestimated blood pressure at hypotensive levels. Best agreement was obtained for SAP and MAP within normotensive limits. At normotension, bias ± standard deviation for SAP, MAP and DAP were 0.1 ± 19.4 mmHg, 0.5 ± 14.0, 4.7 ± 15.6, respectively. At high pressure levels bias and SD were 26.1 ± 37.3 (SAP), 4.2 ± 19.4 (MAP), 1.5 ± 16.8 (DAP) and at low pressures -20.0 ± 20.9 (SAP), -11.4 ± 19.6 (MAP), -4.7 ± 20.1 (DAP), with HDO measurements at a MAP <50 mmHg often failing. CONCLUSION AND CLINICAL RELEVANCE: Good agreement with invasive arterial blood pressures was obtained with HDO at normotensive levels in horses. At high and low pressure ranges HDO was unreliable. Therefore, if haemodynamic instability is expected, invasive measurement remains preferable.
© 2014 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

Entities:  

Keywords:  arterial blood pressure; cardiovascular; equine; oscillometry

Mesh:

Year:  2014        PMID: 25053371     DOI: 10.1111/vaa.12203

Source DB:  PubMed          Journal:  Vet Anaesth Analg        ISSN: 1467-2987            Impact factor:   1.648


  6 in total

Review 1.  Non-invasive blood pressure measurement in animals: Part 1 - Techniques for measurement and validation of non-invasive devices.

Authors:  Alicia Skelding; Alexander Valverde
Journal:  Can Vet J       Date:  2020-04       Impact factor: 1.008

2.  Blood Pressure Reference Intervals for Ketamine-sedated Rhesus Macaques (Macaca mulatta).

Authors:  Rachel D Brownlee; Philip H Kass; Rebecca L Sammak
Journal:  J Am Assoc Lab Anim Sci       Date:  2020-01-02       Impact factor: 1.232

3.  Accuracy and Precision of Noninvasive Blood Pressure in Normo-, Hyper-, and Hypotensive Standing and Anesthetized Adult Horses.

Authors:  N Heliczer; O Lorello; D Casoni; C Navas de Solis
Journal:  J Vet Intern Med       Date:  2016-04-05       Impact factor: 3.333

4.  Blood pressure in Warmblood horses before and during a euglycemic-hyperinsulinemic clamp.

Authors:  Katarina E A Nostell; Sanna S Lindåse; Johan T Bröjer
Journal:  Acta Vet Scand       Date:  2016-10-20       Impact factor: 1.695

5.  Bias Associated with Peripheral Non-Invasive Compared to Invasive Arterial Blood Pressure Monitoring in Healthy Anaesthetised and Standing Horses Using the Bionet BM7Vet.

Authors:  Shaun Pratt; Tamsin S Barnes; Nicholas Cowling; Karla de Klerk; Joanne Rainger; Albert Sole-Guitart; Solomon Woldeyohannes; Wendy Goodwin
Journal:  Vet Sci       Date:  2022-01-28

6.  Agreement of High-Definition Oscillometry (HDO) and Invasive Blood Pressure Measurements at a Metatarsal Artery in Isoflurane-Anaesthetised Horses.

Authors:  Lara Twele; Stephan Neudeck; Julien Delarocque; Nicole Verhaar; Julia Reiners; Mike Noll; Julia Tünsmeyer; Sabine B R Kästner
Journal:  Animals (Basel)       Date:  2022-02-02       Impact factor: 2.752

  6 in total