A Hertault1, B Maurel1, J Sobocinski1, T Martin Gonzalez1, M Le Roux1, R Azzaoui1, M Midulla2, S Haulon3. 1. Vascular Surgery, Hôpital Cardiologique, CHRU de Lille, INSERM U1008, Université Lille Nord de France, 59037 Lille Cedex, France. 2. Radiology, Hôpital Cardiologique, CHRU Lille, INSERM U1008, Université Lille Nord de France, 59037 Lille Cedex, France. 3. Vascular Surgery, Hôpital Cardiologique, CHRU de Lille, INSERM U1008, Université Lille Nord de France, 59037 Lille Cedex, France. Electronic address: stephan.haulon@chru-lille.fr.
Abstract
OBJECTIVE: To evaluate exposure to radiation during endovascular aneurysm repair (EVAR) performed with intraoperative guidance by preoperative computed tomographic angiogram fusion. METHODS: All consecutive patients who underwent standard bifurcated (BIF) or thoracic (THO), and complex fenestrated (FEN) or branched (BR) EVAR were prospectively enrolled. Indirect dose-area product (DAP), fluoroscopy time (FT), and contrast medium volume were recorded. These data were compared with a previously published prospective EVAR cohort of 301 patients and to other literature. Direct DAP and peak skin dose were measured with radiochromic films. Results are expressed as median (interquartile range). RESULTS: From December 2012 to July 2013, 102 patients underwent standard (56.8%) or complex (43.2%) EVAR. The indirect DAP (Gy.cm(2)) was as follows: BIF 12.2 (8.7-19.9); THO 26.0 (11.9-34.9); FEN 43.7 (24.7-57.5); and BR 47.4 (37.2-108.2). The FT (min) was as follows: BIF 10.6 (9.1-14.7); THO 8.9 (6.0-10.5); FEN 30.7 (20.2-40.5); and BR 39.5 (34.8-51.6). The contrast medium volume (mL) was as follows: BIF 59.0 (50.0-75.0); THO 80.0 (50.0-100.0); FEN 105.0 (70.0-136.0); and BR 120.0 (100.0-170.0). When compared with a previous cohort, there was a significant reduction in DAP during BIF, FEN, and BR procedures, and a significant reduction of iodinated contrast volume during FEN and BR procedures. There was also a significant reduction in DAP during BIF procedures when compared with the literature (p < .01). DAP measurement on radiochromic films was strongly correlated with indirect DAP values (r(2) = .93). CONCLUSION: The exposure of patients and operators to radiation is significantly reduced by routine use of image fusion during standard and complex EVAR.
OBJECTIVE: To evaluate exposure to radiation during endovascular aneurysm repair (EVAR) performed with intraoperative guidance by preoperative computed tomographic angiogram fusion. METHODS: All consecutive patients who underwent standard bifurcated (BIF) or thoracic (THO), and complex fenestrated (FEN) or branched (BR) EVAR were prospectively enrolled. Indirect dose-area product (DAP), fluoroscopy time (FT), and contrast medium volume were recorded. These data were compared with a previously published prospective EVAR cohort of 301 patients and to other literature. Direct DAP and peak skin dose were measured with radiochromic films. Results are expressed as median (interquartile range). RESULTS: From December 2012 to July 2013, 102 patients underwent standard (56.8%) or complex (43.2%) EVAR. The indirect DAP (Gy.cm(2)) was as follows: BIF 12.2 (8.7-19.9); THO 26.0 (11.9-34.9); FEN 43.7 (24.7-57.5); and BR 47.4 (37.2-108.2). The FT (min) was as follows: BIF 10.6 (9.1-14.7); THO 8.9 (6.0-10.5); FEN 30.7 (20.2-40.5); and BR 39.5 (34.8-51.6). The contrast medium volume (mL) was as follows: BIF 59.0 (50.0-75.0); THO 80.0 (50.0-100.0); FEN 105.0 (70.0-136.0); and BR 120.0 (100.0-170.0). When compared with a previous cohort, there was a significant reduction in DAP during BIF, FEN, and BR procedures, and a significant reduction of iodinated contrast volume during FEN and BR procedures. There was also a significant reduction in DAP during BIF procedures when compared with the literature (p < .01). DAP measurement on radiochromic films was strongly correlated with indirect DAP values (r(2) = .93). CONCLUSION: The exposure of patients and operators to radiation is significantly reduced by routine use of image fusion during standard and complex EVAR.
Authors: Theodorus M van Bakel; Hector W de Beaufort; Santi Trimarchi; Massimiliano M Marrocco-Trischitta; Jean Bismuth; Frans L Moll; Himanshu J Patel; Joost A van Herwaarden Journal: Ann Cardiothorac Surg Date: 2018-05
Authors: Rui Machado; Vitor Miguel Dias Ferreira; Luis Loureiro; João Gonçalves; Pedro Oliveira; Rui Almeida Journal: Braz J Cardiovasc Surg Date: 2016 Nov-Dec
Authors: E Tuthill; L O'Hora; M O'Donohoe; S Panci; P Gilligan; D Campion; R Trenti; E Fox; D Catania; L Rainford Journal: Eur Radiol Date: 2017-05-18 Impact factor: 5.315
Authors: Romano Sassatelli; Simone Grillo; Marta Ottone; Giulia Besutti; Paolo Cecinato; Giuliana Sereni; Vincenzo Giorgio Mirante; Veronica Iori; Pierpaolo Pattacini; Paolo Giorgi Rossi Journal: Endosc Int Open Date: 2022-05-13