Impact of hybrid rooms with image fusion on radiation exposure during endovascular aortic repair.

A Hertault1, B Maurel1, J Sobocinski1, T Martin Gonzalez1, M Le Roux1, R Azzaoui1, M Midulla2, S Haulon3.   

Abstract

OBJECTIVE: To evaluate exposure to radiation during endovascular aneurysm repair (EVAR) performed with intraoperative guidance by preoperative computed tomographic angiogram fusion.
METHODS: All consecutive patients who underwent standard bifurcated (BIF) or thoracic (THO), and complex fenestrated (FEN) or branched (BR) EVAR were prospectively enrolled. Indirect dose-area product (DAP), fluoroscopy time (FT), and contrast medium volume were recorded. These data were compared with a previously published prospective EVAR cohort of 301 patients and to other literature. Direct DAP and peak skin dose were measured with radiochromic films. Results are expressed as median (interquartile range).
RESULTS: From December 2012 to July 2013, 102 patients underwent standard (56.8%) or complex (43.2%) EVAR. The indirect DAP (Gy.cm(2)) was as follows: BIF 12.2 (8.7-19.9); THO 26.0 (11.9-34.9); FEN 43.7 (24.7-57.5); and BR 47.4 (37.2-108.2). The FT (min) was as follows: BIF 10.6 (9.1-14.7); THO 8.9 (6.0-10.5); FEN 30.7 (20.2-40.5); and BR 39.5 (34.8-51.6). The contrast medium volume (mL) was as follows: BIF 59.0 (50.0-75.0); THO 80.0 (50.0-100.0); FEN 105.0 (70.0-136.0); and BR 120.0 (100.0-170.0). When compared with a previous cohort, there was a significant reduction in DAP during BIF, FEN, and BR procedures, and a significant reduction of iodinated contrast volume during FEN and BR procedures. There was also a significant reduction in DAP during BIF procedures when compared with the literature (p < .01). DAP measurement on radiochromic films was strongly correlated with indirect DAP values (r(2) = .93).
CONCLUSION: The exposure of patients and operators to radiation is significantly reduced by routine use of image fusion during standard and complex EVAR.
Copyright © 2014 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Aorta; Endovascular procedures; Fusion imaging; Hybrid room; Radiation; Radiation protection

Mesh:

Year:  2014        PMID: 25042331     DOI: 10.1016/j.ejvs.2014.05.026

Source DB:  PubMed          Journal:  Eur J Vasc Endovasc Surg        ISSN: 1078-5884            Impact factor:   7.069


  13 in total

1.  [Hybrid operating rooms versus conventional operating rooms : Economic comparisons in vascular surgery using the example of endovascular aneurysm repair].

Authors:  N Attigah; S Demirel; M Hakimi; H Bruijnen; O Schöffski; A Müller; U Geis; D Böckler
Journal:  Chirurg       Date:  2017-07       Impact factor: 0.955

2.  Status of branched endovascular aortic arch repair.

Authors:  Theodorus M van Bakel; Hector W de Beaufort; Santi Trimarchi; Massimiliano M Marrocco-Trischitta; Jean Bismuth; Frans L Moll; Himanshu J Patel; Joost A van Herwaarden
Journal:  Ann Cardiothorac Surg       Date:  2018-05

3.  Radiation Exposure in Endovascular Infra-Renal Aortic Aneurysm Repair and Factors that Influence It.

Authors:  Rui Machado; Vitor Miguel Dias Ferreira; Luis Loureiro; João Gonçalves; Pedro Oliveira; Rui Almeida
Journal:  Braz J Cardiovasc Surg       Date:  2016 Nov-Dec

4.  A versatile intensity-based 3D/2D rigid registration compatible with mobile C-arm for endovascular treatment of abdominal aortic aneurysm.

Authors:  A Duménil; A Kaladji; M Castro; C Göksu; A Lucas; P Haigron
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-05-26       Impact factor: 2.924

5.  Investigation of reference levels and radiation dose associated with abdominal EVAR (endovascular aneurysm repair) procedures across several European Centres.

Authors:  E Tuthill; L O'Hora; M O'Donohoe; S Panci; P Gilligan; D Campion; R Trenti; E Fox; D Catania; L Rainford
Journal:  Eur Radiol       Date:  2017-05-18       Impact factor: 5.315

6.  Fusion radiology in interventional endoscopy (FRIend): a new approach for pancreatic fluid collections.

Authors:  Romano Sassatelli; Simone Grillo; Marta Ottone; Giulia Besutti; Paolo Cecinato; Giuliana Sereni; Vincenzo Giorgio Mirante; Veronica Iori; Pierpaolo Pattacini; Paolo Giorgi Rossi
Journal:  Endosc Int Open       Date:  2022-05-13

7.  Feasibility of Intraoperative Fusion Imaging Using Non-Contrast CT Scan for EVAR in Ruptured Abdominal Aortic Aneurysm.

Authors:  Marc Masana Llimona; Pere Altés Mas; Lucía Martínez Carnovale; Secundino Llagostera Pujol
Journal:  EJVES Vasc Forum       Date:  2020-03-26

8.  Intraoperative stent segmentation in X-ray fluoroscopy for endovascular aortic repair.

Authors:  Katharina Breininger; Shadi Albarqouni; Tanja Kurzendorfer; Marcus Pfister; Markus Kowarschik; Andreas Maier
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-05-19       Impact factor: 2.924

9.  An improved nonlinear diffusion in Laplacian pyramid domain for cone beam CT denoising during image-guided vascular intervention.

Authors:  Yi Liu; Miguel Castro; Mathieu Lederlin; Adrien Kaladji; Pascal Haigron
Journal:  BMC Med Imaging       Date:  2018-09-04       Impact factor: 1.930

10.  Three cases of fusion imaging in endovascular treatment of occlusive peripheral artery disease.

Authors:  Makoto Haga; Takayori Shimizu; Ayako Nishiyama; Shunya Shindo
Journal:  J Vasc Surg Cases Innov Tech       Date:  2019-10-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.