CT based 3-dimensional treatment planning of intracavitary brachytherapy for cancer of the cervix: comparison between dose-volume histograms and ICRU point doses to the rectum and bladder.

Natasha Hashim1, Zulaikha Jamalludin, Ngie Min Ung, Gwo Fuang Ho, Rozita Abdul Malik, Vincent Chee Ee Phua.   

Abstract

BACKGROUND: CT based brachytherapy allows 3-dimensional (3D) assessment of organs at risk (OAR) doses with dose volume histograms (DVHs). The purpose of this study was to compare computed tomography (CT) based volumetric calculations and International Commission on Radiation Units and Measurements (ICRU) reference-point estimates of radiation doses to the bladder and rectum in patients with carcinoma of the cervix treated with high-dose-rate (HDR) intracavitary brachytherapy (ICBT).
MATERIALS AND METHODS: Between March 2011 and May 2012, 20 patients were treated with 55 fractions of brachytherapy using tandem and ovoids and underwent post-implant CT scans. The external beam radiotherapy (EBRT) dose was 48.6 Gy in 27 fractions. HDR brachytherapy was delivered to a dose of 21 Gy in three fractions. The ICRU bladder and rectum point doses along with 4 additional rectal points were recorded. The maximum dose (DMax) to rectum was the highest recorded dose at one of these five points. Using the HDR plus 2.6 brachytherapy treatment planning system, the bladder and rectum were retrospectively contoured on the 55 CT datasets. The DVHs for rectum and bladder were calculated and the minimum doses to the highest irradiated 2cc area of rectum and bladder were recorded (D2cc) for all individual fractions. The mean D2cc of rectum was compared to the means of ICRU rectal point and rectal DMax using the Student's t-test. The mean D2cc of bladder was compared with the mean ICRU bladder point using the same statistical test .The total dose, combining EBRT and HDR brachytherapy, were biologically normalized to the conventional 2 Gy/fraction using the linear-quadratic model. (α/β value of 10 Gy for target, 3 Gy for organs at risk).
RESULTS: The total prescribed dose was 77.5 Gy α/β10. The mean dose to the rectum was 4.58 ± 1.22 Gy for D 2cc, 3.76 ± 0.65 Gy at D ICRU and 4.75 ± 1.01 Gy at DMax. The mean rectal D 2cc dose differed significantly from the mean dose calculated at the ICRU reference point (p<0.005); the mean difference was 0.82 Gy (0.48 -1.19 Gy). The mean EQD2 was 68.52 ± 7.24 Gy α/β3 for D 2cc, 61.71 ± 2.77 Gy α/β3 at D ICRU and 69.24 ± 6.02 Gy α/β3 at DMax. The mean ratio of D 2cc rectum to D ICRU rectum was 1.25 and the mean ratio of D 2cc rectum to DMax rectum was 0.98 for all individual fractions. The mean dose to the bladder was 6.00 ± 1.90 Gy for D 2cc and 5.10 ± 2.03 Gy at D ICRU. However, the mean D 2cc dose did not differ significantly from the mean dose calculated at the ICRU reference point (p=0.307); the mean difference was 0.90 Gy (0.49-1.25 Gy). The mean EQD2 was 81.85 ± 13.03 Gy α/β3 for D 2cc and 74.11 ± 19.39 Gy α/β3 at D ICRU. The mean ratio of D 2cc bladder to D ICRU bladder was 1.24. In the majority of applications, the maximum dose point was not the ICRU point. On average, the rectum received 77% and bladder received 92% of the prescribed dose.
CONCLUSIONS: OARs doses assessed by DVH criteria were higher than ICRU point doses. Our data suggest that the estimated dose to the ICRU bladder point may be a reasonable surrogate for the D 2cc and rectal DMax for D 2cc. However, the dose to the ICRU rectal point does not appear to be a reasonable surrogate for the D 2cc.

Entities:  

Mesh:

Year:  2014        PMID: 25040985     DOI: 10.7314/apjcp.2014.15.13.5259

Source DB:  PubMed          Journal:  Asian Pac J Cancer Prev        ISSN: 1513-7368


  6 in total

1.  Volume Delineation in Cervical Cancer With T2 and Diffusion-weighted MRI: Agreement on Volumes Between Observers.

Authors:  Consuelo Rosa; Andrea Delli Pizzi; Antonietta Augurio; Luciana Caravatta; Monica DI Tommaso; Erica Mincuzzi; Sebastiano Cinalli; Raffaella Basilico; Annamaria Porreca; Marta DI Nicola; Domenico Genovesi
Journal:  In Vivo       Date:  2020 Jul-Aug       Impact factor: 2.155

2.  Error analysis of applicator position for combined internal/external radiation therapy in cervical cancer.

Authors:  Wei Ying; Li Liang; Yu Wang; Guo-Hai Qi
Journal:  Oncol Lett       Date:  2018-07-02       Impact factor: 2.967

3.  Evaluation of Volumetric Doses of Organs at Risk in Carcinoma Cervix Patients with HDR Intracavitary Brachytherapy and Comparison of CT-based and Conventional Plans.

Authors:  S Srivastava; N K Painuly; S P Mishra; K Srivastava; N Singh; S Singh; M L B Bhatt
Journal:  J Biomed Phys Eng       Date:  2019-12-01

4.  Dosimetric study for cervix carcinoma treatment using intensity modulated radiation therapy (IMRT) compensation based on 3D intracavitary brachytherapy technique.

Authors:  Gang Yin; Pei Wang; Jinyi Lang; Yin Tian; Yangkun Luo; Zixuan Fan; Kin Yip Tam
Journal:  J Contemp Brachytherapy       Date:  2016-06-14

5.  Dosimetric Comparison between Three-Dimensional Magnetic Resonance Imaging-Guided and Conventional Two-Dimensional Point A-Based Intracavitary Brachytherapy Planning for Cervical Cancer.

Authors:  Juan Ren; Wei Yuan; Ruihua Wang; Qiuping Wang; Yi Li; Chaofan Xue; Yanli Yan; Xiaowei Ma; Li Tan; Zi Liu
Journal:  PLoS One       Date:  2016-09-09       Impact factor: 3.240

6.  Who Really Benefits from 3D-Based Planning of Brachytherapy for Cervical Cancer?

Authors:  In Bong Ha; Bae Kwon Jeong; Ki Mun Kang; Hojin Jeong; Yun Hee Lee; Hoon Sik Choi; Jong Hak Lee; Won Jun Choi; Jeong Kyu Shin; Jin Ho Song
Journal:  J Korean Med Sci       Date:  2018-04-13       Impact factor: 2.153

  6 in total