Literature DB >> 25029593

Comparison of linear measurements between CBCT orthogonally synthesized cephalograms and conventional cephalograms.

S Yang1, D G Liu, Y Gu.   

Abstract

OBJECTIVES: The purposes of the study are to investigate the consistency of linear measurements between CBCT orthogonally synthesized cephalograms and conventional cephalograms and to evaluate the influence of different magnifications on these comparisons based on a simulation algorithm.
METHODS: Conventional cephalograms and CBCT scans were taken on 12 dry skulls with spherical metal markers. Orthogonally synthesized cephalograms were created from CBCT data. Linear parameters on both cephalograms were measured via Photoshop CS v. 5.0 (Adobe(®) Systems, San Jose, CA), named measurement group (MG). Bland-Altman analysis was utilized to assess the agreement of two imaging modalities. Reproducibility was investigated using paired t-test. By a specific mathematical programme "cepha", corresponding linear parameters [mandibular corpus length (Go-Me), mandibular ramus length (Co-Go), posterior facial height (Go-S)] on these two types of cephalograms were calculated, named simulation group (SG). Bland-Altman analysis was used to assess the agreement between MG and SG. Simulated linear measurements with varying magnifications were generated based on "cepha" as well. Bland-Altman analysis was used to assess the agreement of simulated measurements between two modalities.
RESULTS: Bland-Altman analysis suggested the agreement between measurements on conventional cephalograms and orthogonally synthesized cephalograms, with a mean bias of 0.47 mm. Comparison between MG and SG showed that the difference did not reach clinical significance. The consistency between simulated measurements of both modalities with four different magnifications was demonstrated.
CONCLUSIONS: Normative data of conventional cephalograms could be used for CBCT orthogonally synthesized cephalograms during this transitional period.

Keywords:  Cone beam computed tomography; measurement; orthodontics

Year:  2014        PMID: 25029593      PMCID: PMC4170847          DOI: 10.1259/dmfr.20140024

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  25 in total

1.  Comparison of linear and angular measurements using two-dimensional conventional methods and three-dimensional cone beam CT images reconstructed from a volumetric rendering program in vivo.

Authors:  U Oz; K Orhan; N Abe
Journal:  Dentomaxillofac Radiol       Date:  2011-12       Impact factor: 2.419

2.  Development of imaging selection criteria and procedures should precede cephalometric assessment with cone-beam computed tomography.

Authors:  Allan G Farman; William C Scarfe
Journal:  Am J Orthod Dentofacial Orthop       Date:  2006-08       Impact factor: 2.650

3.  Comparison between conventional and cone-beam computed tomography-generated cephalograms.

Authors:  Paolo M Cattaneo; Christian Borgkvist Bloch; Dorte Calmar; Mette Hjortshøj; Birte Melsen
Journal:  Am J Orthod Dentofacial Orthop       Date:  2008-12       Impact factor: 2.650

4.  Assessment of linear and angular measurements on three-dimensional cone-beam computed tomographic images.

Authors:  Carla R Moreira; Marcelo A O Sales; Patricia M L Lopes; Marcelo G P Cavalcanti
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2009-04-22

5.  A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results.

Authors:  P Mozzo; C Procacci; A Tacconi; P T Martini; I A Andreis
Journal:  Eur Radiol       Date:  1998       Impact factor: 5.315

6.  Working with DICOM craniofacial images.

Authors:  Dan Grauer; Lucia S H Cevidanes; William R Proffit
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-09       Impact factor: 2.650

7.  In vivo comparison of conventional and cone beam CT synthesized cephalograms.

Authors:  Vandana Kumar; John Ludlow; Lucia Helena Soares Cevidanes; André Mol
Journal:  Angle Orthod       Date:  2008-09       Impact factor: 2.079

8.  Accuracy of three-dimensional measurements obtained from cone beam computed tomography surface-rendered images for cephalometric analysis: influence of patient scanning position.

Authors:  Bassam Hassan; Paul van der Stelt; Gerard Sanderink
Journal:  Eur J Orthod       Date:  2008-12-23       Impact factor: 3.075

9.  Comparison of common hard tissue cephalometric measurements between computed tomography 3D reconstruction and conventional 2D cephalometric images.

Authors:  Oded Yitschaky; Meir Redlich; Yossi Abed; Marina Faerman; Nardy Casap; Nurith Hiller
Journal:  Angle Orthod       Date:  2011-01       Impact factor: 2.079

10.  Evaluation of the CT scanogram for assessment of craniofacial morphology.

Authors:  Francis C C Lee; Joseph Harold Noar; Robert David Evans
Journal:  Angle Orthod       Date:  2011-01       Impact factor: 2.079

View more
  2 in total

1.  The Canadian Systemic Sclerosis Oral Health Study IV: oral radiographic manifestations in systemic sclerosis compared with the general population.

Authors:  Marie Dagenais; David MacDonald; Murray Baron; Marie Hudson; Solène Tatibouet; Russell Steele; Sabrina Gravel; Shrisha Mohit; Tarek El Sayegh; Janet Pope; Audrey Fontaine; Ariel Masseto; Debora Matthews; Evelyn Sutton; Norman Thie; Niall Jones; Maria Copete; Dean Kolbinson; Janet Markland; Getulio Nogueira-Filho; David Robinson; Mervyn Gornitsky
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2015-03-25

2.  Craniofacial changes from 13 to 62 years of age.

Authors:  Nameer Al-Taai; Maurits Persson; Maria Ransjö; Eva Levring Jäghagen; Ronny Fors; Anna Westerlund
Journal:  Eur J Orthod       Date:  2022-09-19       Impact factor: 3.131

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.