Literature DB >> 25010918

The effects of positioning of transcatheter aortic valves on fluid dynamics of the aortic root.

Elliott M Groves1,2, Ahmad Falahatpisheh1, Jimmy L Su1,3, Arash Kheradvar1,2,3.   

Abstract

Transcatheter aortic valve implantation is a novel treatment for severe aortic valve stenosis. Due to the recent use of this technology and the procedural variability, there is very little data that quantify the hemodynamic consequences of variations in valve placement. Changes in aortic wall stresses and fluid retention in the sinuses of Valsalva can have a significant effect on the clinical response a patient has to the procedure. By comprehensively characterizing complex flow in the sinuses of Valsalva using digital particle image velocimetry and an advanced heart-flow simulator, various positions of a deployed transcatheter valve with respect to a bioprosthetic aortic valve (valve-in-valve) were tested in vitro. Displacements of the transcatheter valve were axial and directed below the simulated native valve annulus. It was determined that for both blood residence time and aortic Reynolds stresses, it is optimal to have the annulus of the transcatheter valve deployed as close to the aortic valve annulus as possible.

Entities:  

Mesh:

Year:  2014        PMID: 25010918      PMCID: PMC4334568          DOI: 10.1097/MAT.0000000000000107

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  26 in total

1.  Comparison of flow dynamics of Perimount Magna and Magna Ease aortic valve prostheses.

Authors:  Daniel Wendt; Sebastian Stühle; Jarowit Adam Piotrowski; Hermann Wendt; Matthias Thielmann; Heinz Jakob; Wojciech Kowalczyk
Journal:  Biomed Tech (Berl)       Date:  2012-02-22       Impact factor: 1.411

2.  Impact of electrocardiogram-gated multi-slice computed tomography-based aortic annular measurement in the evaluation of paravalvular leakage following transcatheter aortic valve replacement: the efficacy of the OverSized AortiC Annular ratio (OSACA ratio) in TAVR.

Authors:  Koichi Maeda; Toru Kuratani; Kei Torikai; Kazuo Shimamura; Isamu Mizote; Yasuhiro Ichibori; Yasuharu Takeda; Takashi Daimon; Satoshi Nakatani; Shinsuke Nanto; Yoshiki Sawa
Journal:  J Card Surg       Date:  2013-07       Impact factor: 1.620

3.  Development and evaluation of a novel artificial catheter-deliverable prosthetic heart valve and method for in vitro testing.

Authors:  Thomas E Claiborne; Danny Bluestein; Richard T Schoephoerster
Journal:  Int J Artif Organs       Date:  2009-05       Impact factor: 1.595

4.  Particle image velocimetry study of pulsatile flow in bi-leaflet mechanical heart valves with image compensation method.

Authors:  Yubing Shi; Tony Joon Hock Yeo; Yong Zhao; Ned H C Hwang
Journal:  J Biol Phys       Date:  2007-03-28       Impact factor: 1.365

5.  Comparison of feasibility and accuracy of transthoracic echocardiography versus computed tomography in patients with known ascending aortic aneurysm.

Authors:  Gloria Tamborini; Claudia Agnese Galli; Anna Maltagliati; Daniele Andreini; Gianluca Pontone; Carlo Quaglia; Giovanni Ballerini; Mauro Pepi
Journal:  Am J Cardiol       Date:  2006-08-22       Impact factor: 2.778

6.  Cavitation phenomena in mechanical heart valves: studied by using a physical impinging rod system.

Authors:  Chi-Wen Lo; Sheng-Fu Chen; Chi-Pei Li; Po-Chien Lu
Journal:  Ann Biomed Eng       Date:  2010-05-20       Impact factor: 3.934

7.  Patient-specific modeling of biomechanical interaction in transcatheter aortic valve deployment.

Authors:  Qian Wang; Eric Sirois; Wei Sun
Journal:  J Biomech       Date:  2012-06-13       Impact factor: 2.712

8.  Prevention and management of transcatheter balloon-expandable aortic valve malposition.

Authors:  Abdullah M Al Ali; Lukas Altwegg; Eric M Horlick; Christopher Feindel; Christopher R Thompson; Anson Cheung; Ronald G Carere; Karin Humphries; Jian Ye; Jean-Bernard Masson; John G Webb
Journal:  Catheter Cardiovasc Interv       Date:  2008-10-01       Impact factor: 2.692

9.  Reliability of risk algorithms in predicting early and late operative outcomes in high-risk patients undergoing aortic valve replacement.

Authors:  Todd M Dewey; David Brown; William H Ryan; Morley A Herbert; Syma L Prince; Michael J Mack
Journal:  J Thorac Cardiovasc Surg       Date:  2007-11-26       Impact factor: 5.209

Review 10.  Post-stenotic aortic dilatation.

Authors:  Emma Wilton; Marjan Jahangiri
Journal:  J Cardiothorac Surg       Date:  2006-03-03       Impact factor: 1.637

View more
  8 in total

1.  Realistic Vascular Replicator for TAVR Procedures.

Authors:  Oren M Rotman; Brandon Kovarovic; Chander Sadasivan; Luis Gruberg; Baruch B Lieber; Danny Bluestein
Journal:  Cardiovasc Eng Technol       Date:  2018-04-13       Impact factor: 2.495

2.  Coronary Flow Impacts Aortic Leaflet Mechanics and Aortic Sinus Hemodynamics.

Authors:  Brandon L Moore; Lakshmi Prasad Dasi
Journal:  Ann Biomed Eng       Date:  2015-01-31       Impact factor: 3.934

Review 3.  On the Mechanics of Transcatheter Aortic Valve Replacement.

Authors:  Lakshmi P Dasi; Hoda Hatoum; Arash Kheradvar; Ramin Zareian; S Hamed Alavi; Wei Sun; Caitlin Martin; Thuy Pham; Qian Wang; Prem A Midha; Vrishank Raghav; Ajit P Yoganathan
Journal:  Ann Biomed Eng       Date:  2016-11-21       Impact factor: 3.934

Review 4.  Principles of TAVR valve design, modelling, and testing.

Authors:  Oren M Rotman; Matteo Bianchi; Ram P Ghosh; Brandon Kovarovic; Danny Bluestein
Journal:  Expert Rev Med Devices       Date:  2018-10-29       Impact factor: 3.166

5.  Aortic sinus flow stasis likely in valve-in-valve transcatheter aortic valve implantation.

Authors:  Hoda Hatoum; Brandon L Moore; Pablo Maureira; Jennifer Dollery; Juan A Crestanello; Lakshmi Prasad Dasi
Journal:  J Thorac Cardiovasc Surg       Date:  2017-03-23       Impact factor: 5.209

6.  Influence of the tilt angle of Percutaneous Aortic Prosthesis on Velocity and Shear Stress Fields

Authors:  Bruno Alvares de Azevedo Gomes; Gabriel Cordeiro Camargo; Jorge Roberto Lopes Dos Santos; Luis Fernando Alzuguir Azevedo; Ângela Ourivio Nieckele; Aristarco Gonçalves Siqueira-Filho; Glaucia Maria Moraes de Oliveira
Journal:  Arq Bras Cardiol       Date:  2017 Jul-Aug       Impact factor: 2.000

7.  Characterization of Turbulent Flow Behind a Transcatheter Aortic Valve in Different Implantation Positions.

Authors:  Leonardo Pietrasanta; Shaokai Zheng; Dario De Marinis; David Hasler; Dominik Obrist
Journal:  Front Cardiovasc Med       Date:  2022-01-13

8.  Intraventricular Vortex Interaction between Transmitral Flow and Paravalvular Leak.

Authors:  Daisuke Morisawa; Ahmad Falahatpisheh; Eleonora Avenatti; Stephen H Little; Arash Kheradvar
Journal:  Sci Rep       Date:  2018-10-23       Impact factor: 4.379

  8 in total