Literature DB >> 23879340

Impact of electrocardiogram-gated multi-slice computed tomography-based aortic annular measurement in the evaluation of paravalvular leakage following transcatheter aortic valve replacement: the efficacy of the OverSized AortiC Annular ratio (OSACA ratio) in TAVR.

Koichi Maeda1, Toru Kuratani, Kei Torikai, Kazuo Shimamura, Isamu Mizote, Yasuhiro Ichibori, Yasuharu Takeda, Takashi Daimon, Satoshi Nakatani, Shinsuke Nanto, Yoshiki Sawa.   

Abstract

BACKGROUND: Even mild paravalvular leakage (PVL) after transcatheter aortic valve replacement (TAVR) is associated with increased late mortality. Electrocardiogram-gated multi-slice computed tomography (MSCT) enables detailed aortic annulus assessment. We describe the impact of MSCT for PVL following TAVR.
METHODS: Congruence between the prosthesis and annulus diameters affects PVL; therefore, we calculated the OverSized AortiC Annular ratio (OSACA ratio) and OSACA (transesophageal echocardiography, TEE) ratio as prosthesis diameter/annulus diameter on MSCT or TEE, respectively, and compared their relationship with PVL ≤ trace following TAVR.
RESULTS: Of 36 consecutive patients undergoing TAVR (Group A), the occurrence of PVL ≤ trace (33.3%) was significantly related to the OSACA ratio (p = 0.00020). In receiver-operating characteristics analysis, the cutoff value of 1.03 for the OSACA ratio had the highest sum of sensitivity (75.0%) and specificity (91.7%; AUC = 0.87) with significantly higher discriminatory performance for PVL as compared to the OSACA (TEE) ratio (AUC = 0.69, p = 0.028). In nine consecutive patients (Group B) undergoing TAVR based on guidelines formulated from our experience with Group A, PVL ≤ trace was significantly more frequent (88.9%) than that in Group A (p = 0.0060).
CONCLUSIONS: The OSACA ratio has a significantly higher discriminatory performance for PVL ≤ trace than the OSACA (TEE) ratio, and aortic annular measurement from MSCT is more accurate than that from TEE.
© 2013 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2013        PMID: 23879340     DOI: 10.1111/jocs.12143

Source DB:  PubMed          Journal:  J Card Surg        ISSN: 0886-0440            Impact factor:   1.620


  1 in total

1.  The effects of positioning of transcatheter aortic valves on fluid dynamics of the aortic root.

Authors:  Elliott M Groves; Ahmad Falahatpisheh; Jimmy L Su; Arash Kheradvar
Journal:  ASAIO J       Date:  2014 Sep-Oct       Impact factor: 2.872

  1 in total