Literature DB >> 25008003

Estimation of flexible needle deflection in layered soft tissues with different elastic moduli.

Hyosang Lee1, Jung Kim.   

Abstract

The estimation of needle deflection when the needle interacts with biological tissue is challenging in needle steering. Most previous studies have used homogeneous tissue models to estimate the deflection of a needle. However, biological tissue typically has a layered structure with variable mechanical properties and geometric features. In this study, we propose a needle deflection model with a double-layered elastic medium. Each layer possesses distinct mechanical properties, which result in inconsistent degrees of friction force on the needle surface, needle-cutting force, and forces caused by the stiffness of the elastic medium. The model uses the Rayleigh-Ritz method to analytically estimate the needle deflection. To validate the model, needle steering experiments were performed using double-layered tissue phantoms and porcine tissues. The experimental results revealed that changes in reaction force at the needle base occurred when the needle passed through the boundary between the two layers. The mean absolute error between the estimated and measured needle tip trajectory was 0.88 ± 0.30 mm for the double-layered tissue phantom and 1.85 ± 0.73 mm for the porcine tissue. These results are comparable with previous studies of homogeneous tissue. The proposed model could improve needle steering in biological tissues, which consist of multiple layers.

Mesh:

Year:  2014        PMID: 25008003     DOI: 10.1007/s11517-014-1173-7

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  12 in total

1.  Force modeling for needle insertion into soft tissue.

Authors:  Allison M Okamura; Christina Simone; Mark D O'Leary
Journal:  IEEE Trans Biomed Eng       Date:  2004-10       Impact factor: 4.538

2.  Clinical risk factors associated with bleeding after native kidney biopsy.

Authors:  Ganesh B Shidham; Nauman Siddiqi; Joseph A Beres; Brent Logan; H N Nagaraja; Shubhangi G Shidham; Walter F Piering
Journal:  Nephrology (Carlton)       Date:  2005-06       Impact factor: 2.506

3.  Soft tissue elastometer.

Authors:  V Egorov; S Tsyuryupa; S Kanilo; M Kogit; A Sarvazyan
Journal:  Med Eng Phys       Date:  2007-03-23       Impact factor: 2.242

4.  Transperineal prostate biopsy under magnetic resonance image guidance: a needle placement accuracy study.

Authors:  Philip Blumenfeld; Nobuhiko Hata; Simon DiMaio; Kelly Zou; Steven Haker; Gabor Fichtinger; Clare M C Tempany
Journal:  J Magn Reson Imaging       Date:  2007-09       Impact factor: 4.813

5.  Flexible needle-tissue interaction modeling with depth-varying mean parameter: preliminary study.

Authors:  Kai Guo Yan; Tarun Podder; Yan Yu; Tien-I Liu; Christopher W S Cheng; Wan Sing Ng
Journal:  IEEE Trans Biomed Eng       Date:  2009-02       Impact factor: 4.538

6.  Bleeding after liver biopsy.

Authors:  A S Mahal; C M Knauer; P B Gregory
Journal:  West J Med       Date:  1981-01

7.  Mechanics of Flexible Needles Robotically Steered through Soft Tissue.

Authors:  S Misra; K B Reed; B W Schafer; K T Ramesh; A M Okamura
Journal:  Int J Rob Res       Date:  2010-11       Impact factor: 4.703

8.  Estimation of fracture toughness of liver tissue: experiments and validation.

Authors:  Can Gokgol; Cagatay Basdogan; Demircan Canadinc
Journal:  Med Eng Phys       Date:  2011-10-24       Impact factor: 2.242

9.  Mechanics of dynamic needle insertion into a biological material.

Authors:  Mohsen Mahvash; Pierre E Dupont
Journal:  IEEE Trans Biomed Eng       Date:  2009-11-20       Impact factor: 4.538

Review 10.  Interventional navigation systems for treatment of unresectable liver tumor.

Authors:  Soo Jay Phee; Kai Yang
Journal:  Med Biol Eng Comput       Date:  2009-12-30       Impact factor: 2.602

View more
  3 in total

1.  Development of a compact continuum tubular robotic system for nasopharyngeal biopsy.

Authors:  Liao Wu; Shuang Song; Keyu Wu; Chwee Ming Lim; Hongliang Ren
Journal:  Med Biol Eng Comput       Date:  2016-05-18       Impact factor: 2.602

2.  A data-driven soft sensor for needle deflection in heterogeneous tissue using just-in-time modelling.

Authors:  Carlos Rossa; Thomas Lehmann; Ronald Sloboda; Nawaid Usmani; Mahdi Tavakoli
Journal:  Med Biol Eng Comput       Date:  2016-12-10       Impact factor: 2.602

3.  Preoperative Needle Insertion Path Planning for Minimizing Deflection in Multilayered Tissues.

Authors:  Ryosuke Tsumura; Jin Seob Kim; Hiroyasu Iwata; Iulian Iordachita
Journal:  IEEE Robot Autom Lett       Date:  2018-02-27
  3 in total