Daniel H Paulus1, Daniela Thorwath2, Holger Schmidt3, Harald H Quick4. 1. Institute of Medical Physics, Friedrich-Alexander-University of Erlangen-Nuremberg, Erlangen 91052, Germany. 2. Section for Biomedical Physics, University Hospital for Radiation Oncology, Eberhard Karls University Tübingen, Tübingen 72076, Germany. 3. Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tübingen, Tübingen 72076, Germany; Laboratory for Preclinical Imaging and Imaging Technology of the Werner Siemens-Foundation, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University Tübingen, Tübingen 72076, Germany. 4. Institute of Medical Physics, Friedrich-Alexander-University of Erlangen-Nuremberg, Erlangen 91052, Germany; Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen 45141, Germany; and High Field and Hybrid MR-Imaging, University Hospital Essen, Essen 45147, Germany.
Abstract
PURPOSE: Multimodality imaging has become an important adjunct of state-of-the-art radiation therapy (RT) treatment planning. Recently, simultaneous PET/MR hybrid imaging has become clinically available and may also contribute to target volume delineation and biological individualization in RT planning. For integration of PET/MR hybrid imaging into RT treatment planning, compatible dedicated RT devices are required for accurate patient positioning. In this study, prototype RT positioning devices intended for PET/MR hybrid imaging are introduced and tested toward PET/MR compatibility and image quality. METHODS: A prototype flat RT table overlay and two radiofrequency (RF) coil holders that each fix one flexible body matrix RF coil for RT head/neck imaging have been evaluated within this study. MR image quality with the RT head setup was compared to the actual PET/MR setup with a dedicated head RF coil. PET photon attenuation and CT-based attenuation correction (AC) of the hardware components has been quantitatively evaluated by phantom scans. Clinical application of the new RT setup in PET/MR imaging was evaluated in anin vivo study. RESULTS: The RT table overlay and RF coil holders are fully PET/MR compatible. MR phantom and volunteer imaging with the RT head setup revealed high image quality, comparable to images acquired with the dedicated PET/MR head RF coil, albeit with 25% reduced SNR. Repositioning accuracy of the RF coil holders was below 1 mm. PET photon attenuation of the RT table overlay was calculated to be 3.8% and 13.8% for the RF coil holders. With CT-based AC of the devices, the underestimation error was reduced to 0.6% and 0.8%, respectively. Comparable results were found within the patient study. CONCLUSIONS: The newly designed RT devices for hybrid PET/MR imaging are PET and MR compatible. The mechanically rigid design and the reproducible positioning allow for straightforward CT-based AC. The systematic evaluation within this study provides the technical basis for the clinical integration of PET/MR hybrid imaging into RT treatment planning.
PURPOSE: Multimodality imaging has become an important adjunct of state-of-the-art radiation therapy (RT) treatment planning. Recently, simultaneous PET/MR hybrid imaging has become clinically available and may also contribute to target volume delineation and biological individualization in RT planning. For integration of PET/MR hybrid imaging into RT treatment planning, compatible dedicated RT devices are required for accurate patient positioning. In this study, prototype RT positioning devices intended for PET/MR hybrid imaging are introduced and tested toward PET/MR compatibility and image quality. METHODS: A prototype flat RT table overlay and two radiofrequency (RF) coil holders that each fix one flexible body matrix RF coil for RT head/neck imaging have been evaluated within this study. MR image quality with the RT head setup was compared to the actual PET/MR setup with a dedicated head RF coil. PET photon attenuation and CT-based attenuation correction (AC) of the hardware components has been quantitatively evaluated by phantom scans. Clinical application of the new RT setup in PET/MR imaging was evaluated in anin vivo study. RESULTS: The RT table overlay and RF coil holders are fully PET/MR compatible. MR phantom and volunteer imaging with the RT head setup revealed high image quality, comparable to images acquired with the dedicated PET/MR head RF coil, albeit with 25% reduced SNR. Repositioning accuracy of the RF coil holders was below 1 mm. PET photon attenuation of the RT table overlay was calculated to be 3.8% and 13.8% for the RF coil holders. With CT-based AC of the devices, the underestimation error was reduced to 0.6% and 0.8%, respectively. Comparable results were found within the patient study. CONCLUSIONS: The newly designed RT devices for hybrid PET/MR imaging are PET and MR compatible. The mechanically rigid design and the reproducible positioning allow for straightforward CT-based AC. The systematic evaluation within this study provides the technical basis for the clinical integration of PET/MR hybrid imaging into RT treatment planning.
Authors: D L Bailey; B J Pichler; B Gückel; H Barthel; A J Beer; J Bremerich; J Czernin; A Drzezga; C Franzius; V Goh; M Hartenbach; H Iida; A Kjaer; C la Fougère; C N Ladefoged; I Law; K Nikolaou; H H Quick; O Sabri; J Schäfer; M Schäfers; H F Wehrl; T Beyer Journal: Mol Imaging Biol Date: 2015-10 Impact factor: 3.488
Authors: Kerstin Zwirner; Daniela Thorwarth; René M Winter; Stefan Welz; Jakob Weiss; Nina F Schwenzer; Holger Schmidt; Christian la Fougère; Konstantin Nikolaou; Daniel Zips; Sergios Gatidis Journal: Strahlenther Onkol Date: 2018-03-21 Impact factor: 3.621
Authors: Gaël Amzalag; Olivier Rager; Claire Tabouret-Viaud; Michael Wissmeyer; Electra Sfakianaki; Thomas de Perrot; Osman Ratib; Raymond Miralbell; Giampiero Giovacchini; Valentina Garibotto; Thomas Zilli Journal: Front Oncol Date: 2016-03-31 Impact factor: 6.244
Authors: René M Winter; Sara Leibfarth; Holger Schmidt; Kerstin Zwirner; David Mönnich; Stefan Welz; Nina F Schwenzer; Christian la Fougère; Konstantin Nikolaou; Sergios Gatidis; Daniel Zips; Daniela Thorwarth Journal: Radiother Oncol Date: 2018-05-07 Impact factor: 6.280