Literature DB >> 24986940

The use of a lipped acetabular liner decreases the rate of revision for instability after total hip replacement: a study using data from the New Zealand Joint Registry.

P J Insull1, H Cobbett2, C M Frampton3, J T Munro4.   

Abstract

We compared the rate of revision for instability after total hip replacement (THR) when lipped and non-lipped acetabular liners were used. We hypothesised that the use of a lipped liner in a modular uncemented acetabular component reduces the risk of revision for instability after primary THR. Using data from the New Zealand Joint Registry, we found that the use of a lipped liner was associated with a significantly decreased rate of revision for instability and for all other indications. Adjusting for the size of the femoral head, the surgical approach and the age and gender of the patient, this difference remained strongly significant (p < 0.001). We conclude that evidence from the New Zealand registry suggests that the use of lipped liners with modular uncemented acetabular components is associated with a decreased rate of revision for instability after primary THR. ©2014 The British Editorial Society of Bone & Joint Surgery.

Entities:  

Keywords:  Instability; Revision; Total hip arthroplasty

Mesh:

Year:  2014        PMID: 24986940     DOI: 10.1302/0301-620X.96B7.33658

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  11 in total

1.  Are Hooded, Crosslinked Polyethylene Liners Associated with a Reduced Risk of Revision After THA?

Authors:  Adrian Bauze; Somen Agrawal; Alana Cuthbert; Richard de Steiger
Journal:  Clin Orthop Relat Res       Date:  2019-06       Impact factor: 4.176

2.  CORR Insights®: Are Hooded, Crosslinked Polyethylene Liners Associated with a Reduced Risk of Revision After THA?

Authors:  Ola Rolfson
Journal:  Clin Orthop Relat Res       Date:  2019-06       Impact factor: 4.176

Review 3.  [Hip replacement in patients with neuromuscular disorders].

Authors:  L Renner; V Drwal; F Boettner
Journal:  Orthopade       Date:  2015-07       Impact factor: 1.087

Review 4.  Total hip arthroplasty instability in Italy.

Authors:  Francesco Falez; Matteo Papalia; Fabio Favetti; Gabriele Panegrossi; Filippo Casella; Gianluca Mazzotta
Journal:  Int Orthop       Date:  2016-12-20       Impact factor: 3.075

5.  Survival of 11,390 Continuum cups in primary total hip arthroplasty based on data from the Finnish Arthroplasty Register.

Authors:  Matias Hemmilä; Mikko Karvonen; Inari Laaksonen; Markus Matilainen; Antti Eskelinen; Jaason Haapakoski; Ari-Pekka Puhto; Jukka Kettunen; Mikko Manninen; Keijo T Mäkelä
Journal:  Acta Orthop       Date:  2019-04-17       Impact factor: 3.717

6.  Computer simulation of optimal lipped polyethylene liner orientation against prosthetic impingement.

Authors:  Yi Hu; Xianhao Zhou; Hua Qiao; Zhenan Zhu; Huiwu Li; Jingwei Zhang
Journal:  J Orthop Surg Res       Date:  2022-04-04       Impact factor: 2.359

7.  Are Lipped Polyethylene Liners Associated with Increased Revision Rates in Patients with Uncemented Acetabular Components? An Observational Cohort Study.

Authors:  Michael C Wyatt; Michael R Whitehouse; David C Kieser; Chris M A Frampton; Gary J Hooper
Journal:  Clin Orthop Relat Res       Date:  2020-03       Impact factor: 4.755

8.  Optimal position of lipped acetabular liners to improve stability in total hip arthroplasty-an intraoperative in vivo study.

Authors:  Raphael Hau; Joshua Hammeschlag; Christopher Law; Kemble K Wang
Journal:  J Orthop Surg Res       Date:  2018-11-19       Impact factor: 2.359

9.  Invagination of elevated lip liner preventing reduction of dislocated total hip.

Authors:  Angel Ordaz; Joseph Schirmers; Stefano Bini
Journal:  Arthroplast Today       Date:  2020-01-07

10.  The prevalence of elevated-rim polyethylene liner use in primary total hip arthroplasty in the New York State metropolitan area.

Authors:  Omar A Behery; William J Long
Journal:  Arthroplast Today       Date:  2019-11-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.