Literature DB >> 31714411

Are Lipped Polyethylene Liners Associated with Increased Revision Rates in Patients with Uncemented Acetabular Components? An Observational Cohort Study.

Michael C Wyatt1,2, Michael R Whitehouse3,4, David C Kieser5, Chris M A Frampton5, Gary J Hooper5.   

Abstract

BACKGROUND: Recurrent dislocation after THA remains a serious complication that carries with it a high risk of revision surgery. Previous studies have shown reduced dislocation rates with the use of lipped polyethylene (PE) liners in modular uncemented acetabular components, but there may be increased wear because of impingement, which may lead to aseptic loosening in the longer term; whether the aggregate benefit of lipped PE liners outweighs the risks associated with their use remains controversial. QUESTIONS/PURPOSES: We used data from the New Zealand Joint Registry to (1) compare Kaplan-Meier survival rates, (2) rates of revisions for dislocation between neutral and lipped PE liners, and (3) revision rates for aseptic loosening for the four most commonly used modular uncemented cups.
METHODS: We used data from the New Zealand Joint Registry (NZJR) to identify 31,247 primary THAs using the four most commonly used uncemented modular acetabular implants from January 1, 1999 to December 31, 2018. The lipped liner group comprised 49% males (9924 of 20,240) compared with 42% (4669 of 11,007) in the neutral group (p < 0.001); 96% (19,382 of 20,240) of patients in the liner group had OA versus 95% (10,450 of 11,007) in the neutral group (p < 0.001). There was no difference in other patient characteristics such as age (mean 66.9 years), BMI (mean 29 ± 6 kg/m) and American Society of Anesthesiologists grade. The mean follow-up was 5.1 years (SD 3.9) and longest follow-up 19.3 years. The NZJR has more than 96% capture rate and data entry is a mandatory requirement of members of the New Zealand Orthopaedic Association. Kaplan-Meier survival rates were compared between 20,240 lipped and 11,007 neutral PE liners. Highly cross-linked polyethylene was used in 99% of lipped liner cups and 85% of neutral liner cups. Associated hazard ratios were calculated using a Cox regression analysis with a Kaplan-Meier revision-free estimates plot.
RESULTS: The Kaplan-Meier survival at 10 years for lipped PE liners was 96% (95% confidence interval 95.4 to 96.2) and for neutral liners 95% (95% CI 94.7 to 95.9). After controlling for age, gender approach, femoral head size, and the use of image guidance, the all-cause revision risk was greater for neutral PE liners than that for lipped PE liners (HR 1.17 [95% CI 1.06 to 1.36]; p = 0.032). There was a higher risk of revision for dislocation in those with neutral PE liners than in those with lipped liners (HR 1.84 [95% CI 1.41 to 2.41]; p < 0.001) but no difference in the revision rate for aseptic acetabular component loosening (HR 0.85 [95% CI 0.52 to 1.38]; p = 0.511).
CONCLUSIONS: The use of a lipped PE liner is not associated with a higher rate of aseptic loosening in patients who undergo primary THA compared with a neutral PE liner. Lipped PE liners are associated with lower rates of dislocation and lower all-cause revision rates without any increased association with revision rates for wear and aseptic loosening. LEVEL OF EVIDENCE: Level III, therapeutic study.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 31714411      PMCID: PMC7145090          DOI: 10.1097/CORR.0000000000001039

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.755


  14 in total

Review 1.  Survival outcomes of cemented compared to uncemented stems in primary total hip replacement.

Authors:  Michael Wyatt; Gary Hooper; Christopher Frampton; Alastair Rothwell
Journal:  World J Orthop       Date:  2014-11-18

2.  Instability after total hip arthroplasty.

Authors:  Brian C Werner; Thomas E Brown
Journal:  World J Orthop       Date:  2012-08-18

3.  The use of a lipped acetabular liner decreases the rate of revision for instability after total hip replacement: a study using data from the New Zealand Joint Registry.

Authors:  P J Insull; H Cobbett; C M Frampton; J T Munro
Journal:  Bone Joint J       Date:  2014-07       Impact factor: 5.082

4.  Highly Cross-Linked Polyethylene Reduces Wear and Revision Rates in Total Hip Arthroplasty: A 10-Year Double-Blinded Randomized Controlled Trial.

Authors:  Peter A Devane; James Geoffrey Horne; Alexander Ashmore; Jonathon Mutimer; Woosung Kim; James Stanley
Journal:  J Bone Joint Surg Am       Date:  2017-10-18       Impact factor: 5.284

5.  Predicting 30-day mortality following hip fracture surgery: evaluation of six risk prediction models.

Authors:  Julian Karres; Nicole A Heesakkers; Jan M Ultee; Bart C Vrouenraets
Journal:  Injury       Date:  2014-11-15       Impact factor: 2.586

6.  Discriminative ability of commonly used indices to predict adverse outcomes after poster lumbar fusion: a comparison of demographics, ASA, the modified Charlson Comorbidity Index, and the modified Frailty Index.

Authors:  Nathaniel T Ondeck; Daniel D Bohl; Patawut Bovonratwet; Ryan P McLynn; Jonathan J Cui; Blake N Shultz; Adam M Lukasiewicz; Jonathan N Grauer
Journal:  Spine J       Date:  2017-05-31       Impact factor: 4.166

7.  Independent contribution of elevated-rim acetabular liner and femoral head size to the stability of total hip implants.

Authors:  P G Sultan; V Tan; M Lai; J P Garino
Journal:  J Arthroplasty       Date:  2002-04       Impact factor: 4.757

8.  The value of arthroplasty registry data.

Authors:  Stephen E Graves
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

9.  Future young patient demand for primary and revision joint replacement: national projections from 2010 to 2030.

Authors:  Steven M Kurtz; Edmund Lau; Kevin Ong; Ke Zhao; Michael Kelly; Kevin J Bozic
Journal:  Clin Orthop Relat Res       Date:  2009-04-10       Impact factor: 4.176

10.  The effect of patient age at intervention on risk of implant revision after total replacement of the hip or knee: a population-based cohort study.

Authors:  Lee E Bayliss; David Culliford; A Paul Monk; Sion Glyn-Jones; Daniel Prieto-Alhambra; Andrew Judge; Cyrus Cooper; Andrew J Carr; Nigel K Arden; David J Beard; Andrew J Price
Journal:  Lancet       Date:  2017-02-14       Impact factor: 79.321

View more
  2 in total

Review 1.  Use of elevated liners in primary total hip arthroplasty: a systematic review of the literature.

Authors:  Ioannis Gkiatas; Theofilos Karasavvidis; Abhinav K Sharma; William Xiang; Michael-Alexander Malahias; Brian P Chalmers; Seth A Jerabek; Peter K Sculco
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-05-29

2.  CORR Insights®: Are Lipped Polyethylene Liners Associated with Increased Revision Rates in Patients with Uncemented Acetabular Components? An Observational Cohort Study.

Authors:  Rocco P Pitto
Journal:  Clin Orthop Relat Res       Date:  2020-03       Impact factor: 4.755

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.