Evaluation of a novel accelerometer for kinetic gait analysis in dogs.

Kyle Clark1, Charles Caraguel1, Lorne Leahey1, Romain Béraud1.   

Abstract

The objective of this study was to evaluate a novel accelerometer-based sensor system, the Walkabout Portable Gait Monitor (WPGM), for use in kinetic gait analysis of dogs. The accelerometer was compared to the common reference standard of force platform analysis. Fifteen client-owned, orthopedically sound dogs of various breeds underwent simultaneous force platform and accelerometer gait trials to measure peak vertical forces (PVFs). The agreement between PVF for the accelerometer and force platform was measured using concordance correlation coefficient (CCC) and was found, overall, to be moderate [CCC = 0.51; 95% confidence interval (CI): 0.46 to 0.56]. The agreement between PVF for the accelerometer and force platform for the forelimbs was positive and substantial (CCC = 0.79; 95% CI: 0.74 to 0.84) and for the hind limbs was positive and low (CCC = 0.34; 95% CI: 0.29 to 0.38). As measured by the accelerometer, PVF was systematically higher than as measured by the force platform (forelimbs 55.3 N, hind limbs 144.3 N). It was also found that, when positioned over the lumbar spine, the WPGM cannot measure PVF of the individual forelimbs and hind limbs, which limits its use as a clinical tool to measure kinetic variables in dogs.

Entities:  

Mesh:

Year:  2014        PMID: 24982555      PMCID: PMC4068415     

Source DB:  PubMed          Journal:  Can J Vet Res        ISSN: 0830-9000            Impact factor:   1.310


  28 in total

1.  Evaluation of agreement between numerical rating scales, visual analogue scoring scales, and force plate gait analysis in dogs.

Authors:  Margaret M Quinn; Nicholas S Keuler; Yan Lu; Maria L E Faria; Peter Muir; Mark D Markel
Journal:  Vet Surg       Date:  2007-06       Impact factor: 1.495

2.  Accuracy of asymmetry indices of ground reaction forces for diagnosis of hind limb lameness in dogs.

Authors:  Laurent Fanchon; Dominique Grandjean
Journal:  Am J Vet Res       Date:  2007-10       Impact factor: 1.156

Review 3.  An overview on assessing agreement with continuous measurements.

Authors:  Huiman X Barnhart; Michael J Haber; Lawrence I Lin
Journal:  J Biopharm Stat       Date:  2007       Impact factor: 1.051

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Ground reaction force profiles from force platform gait analyses of clinically normal mesomorphic dogs at the trot.

Authors:  P F Rumph; J E Lander; S A Kincaid; D K Baird; J R Kammermann; D M Visco
Journal:  Am J Vet Res       Date:  1994-06       Impact factor: 1.156

6.  Evaluation of a pressure walkway system for measurement of vertical limb forces in clinically normal dogs.

Authors:  B Duncan X Lascelles; Simon C Roe; Eric Smith; Lisa Reynolds; Jacqueline Markham; Denis Marcellin-Little; Mary Sarah Bergh; Steven C Budsberg
Journal:  Am J Vet Res       Date:  2006-02       Impact factor: 1.156

7.  Accuracy and optimization of force platform gait analysis in Labradors with cranial cruciate disease evaluated at a walking gait.

Authors:  Richard Evans; Chris Horstman; Mike Conzemius
Journal:  Vet Surg       Date:  2005 Sep-Oct       Impact factor: 1.495

8.  Use of pedometers to measure physical activity in dogs.

Authors:  Catherine B Chan; Marguerite Spierenburg; Sherri L Ihle; Catrine Tudor-Locke
Journal:  J Am Vet Med Assoc       Date:  2005-06-15       Impact factor: 1.936

9.  Evaluation of an accelerometer for at-home monitoring of spontaneous activity in dogs.

Authors:  Bernard D Hansen; B Duncan X Lascelles; Bruce W Keene; Allison K Adams; Andrea E Thomson
Journal:  Am J Vet Res       Date:  2007-05       Impact factor: 1.156

10.  Force plate analysis of the walking gait in healthy dogs.

Authors:  S C Budsberg; M C Verstraete; R W Soutas-Little
Journal:  Am J Vet Res       Date:  1987-06       Impact factor: 1.156

View more
  5 in total

1.  Detection of Generalized Tonic-Clonic Seizures in Dogs With a Seizure Detection System Established Using Acceleration Data and the Mahalanobis Distance: A Preliminary Study.

Authors:  Junya Hirashima; Miyoko Saito; Tsukasa Kuriyama; Taketo Akamatsu; Minoru Yokomori
Journal:  Front Vet Sci       Date:  2022-04-28

2.  The chondrodystrophic dog: A clinically relevant intermediate-sized animal model for the study of intervertebral disc-associated spinal pain.

Authors:  Kelly Thompson; Sarah Moore; Shirley Tang; Matthew Wiet; Devina Purmessur
Journal:  JOR Spine       Date:  2018-03-28

3.  Four-limb wireless IMU sensor system for automatic gait detection in canines.

Authors:  Xiqiao Zhang; Gregory J Jenkins; Chady H Hakim; Dongsheng Duan; Gang Yao
Journal:  Sci Rep       Date:  2022-03-21       Impact factor: 4.379

4.  A step in the right direction: an open-design pedometer algorithm for dogs.

Authors:  C Ladha; Z Belshaw; J O'Sullivan; L Asher
Journal:  BMC Vet Res       Date:  2018-03-20       Impact factor: 2.741

5.  Automatic characterization of stride parameters in canines with a single wearable inertial sensor.

Authors:  Gregory J Jenkins; Chady H Hakim; N Nora Yang; Gang Yao; Dongsheng Duan
Journal:  PLoS One       Date:  2018-06-14       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.