Literature DB >> 24973842

Safety and efficacy of the Yukon Choice Flex sirolimus-eluting coronary stent in an all-comers population cohort.

E Xhepa1, T Tada1, S Cassese1, L King1, I Ott1, M Fusaro1, A Kastrati2, R A Byrne1.   

Abstract

AIMS: The use of biodegradable-polymer drug-eluting stents has been shown to provide favorable results when compared with durable polymer drug-eluting stents and long-term follow up data have recently shown significant reductions in terms of very late stent thrombosis. Aim of the present study was to assess the safety and efficacy profile of a novel biodegradable polymer DES, the Yukon Choice Flex sirolimus-eluting stent.
METHODS: We report here the one-year clinical outcomes associated with the use of the Yukon Choice Flex sirolimus-eluting stent in an all-comers patient population. The present stent represents a further refinement of the stent platform tested in the ISAR TEST 3 and 4 randomized clinical trials. A total of 778 consecutive patients undergoing implantation of this stent were enrolled in the present observational study and prospectively followed for one year.
RESULTS: The use of the Yukon Choice Flex stent in a patient population with complex coronary lesion morphology was associated with optimal immediate angiographic results. At one year follow up the rates of death, myocardial infarction, definite stent thrombosis and ischemia-driven target lesion revascularization were respectively 2.4%, 1.9%, 0.3% and 11.3%.
CONCLUSIONS: The use of the sirolimus-eluting biodegradable polymer Yukon Choice Flex stent in an all-comers population of patients with complex coronary artery disease is associated with a favorable safety and efficacy profile up to one year follow up.
Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Bioresorbable-polymer drug-eluting stent; Percutaneous coronary intervention; Stent thrombosis

Mesh:

Substances:

Year:  2014        PMID: 24973842      PMCID: PMC4121760          DOI: 10.1016/j.ihj.2014.05.003

Source DB:  PubMed          Journal:  Indian Heart J        ISSN: 0019-4832


  27 in total

1.  Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk.

Authors:  Michael Joner; Aloke V Finn; Andrew Farb; Erik K Mont; Frank D Kolodgie; Elena Ladich; Robert Kutys; Kristi Skorija; Herman K Gold; Renu Virmani
Journal:  J Am Coll Cardiol       Date:  2006-05-05       Impact factor: 24.094

2.  Inhibition of neointima formation by a novel drug-eluting stent system that allows for dose-adjustable, multiple, and on-site stent coating.

Authors:  Rainer Wessely; Jörg Hausleiter; Cornelia Michaelis; Birgit Jaschke; Michael Vogeser; Stefan Milz; Boris Behnisch; Thomas Schratzenstaller; Magdalena Renke-Gluszko; Michael Stöver; Erich Wintermantel; Adnan Kastrati; Albert Schömig
Journal:  Arterioscler Thromb Vasc Biol       Date:  2005-01-27       Impact factor: 8.311

3.  A pooled analysis of data comparing sirolimus-eluting stents with bare-metal stents.

Authors:  Christian Spaulding; Joost Daemen; Eric Boersma; Donald E Cutlip; Patrick W Serruys
Journal:  N Engl J Med       Date:  2007-02-12       Impact factor: 91.245

4.  Analysis of 14 trials comparing sirolimus-eluting stents with bare-metal stents.

Authors:  Adnan Kastrati; Julinda Mehilli; Jürgen Pache; Christoph Kaiser; Marco Valgimigli; Henning Kelbaek; Maurizio Menichelli; Manel Sabaté; Maarten J Suttorp; Dietrich Baumgart; Melchior Seyfarth; Matthias E Pfisterer; Albert Schömig
Journal:  N Engl J Med       Date:  2007-02-12       Impact factor: 91.245

5.  Clinical outcomes and stent thrombosis following off-label use of drug-eluting stents.

Authors:  Htut K Win; Angel E Caldera; Kelly Maresh; John Lopez; Charanjit S Rihal; Manish A Parikh; Juan F Granada; Sachin Marulkar; Deborah Nassif; David J Cohen; Neal S Kleiman
Journal:  JAMA       Date:  2007-05-09       Impact factor: 56.272

6.  Improved safety and reduction in stent thrombosis associated with biodegradable polymer-based biolimus-eluting stents versus durable polymer-based sirolimus-eluting stents in patients with coronary artery disease: final 5-year report of the LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) randomized, noninferiority trial.

Authors:  Patrick W Serruys; Vasim Farooq; Bindu Kalesan; Ton de Vries; Pawel Buszman; Axel Linke; Thomas Ischinger; Volker Klauss; Franz Eberli; William Wijns; Marie Claude Morice; Carlo Di Mario; Roberto Corti; Diethmar Antoni; Hae Y Sohn; Pedro Eerdmans; Tessa Rademaker-Havinga; Gerrit-Anne van Es; Bernhard Meier; Peter Jüni; Stephan Windecker
Journal:  JACC Cardiovasc Interv       Date:  2013-08       Impact factor: 11.195

Review 7.  Sirolimus and Paclitaxel on polymer-based drug-eluting stents: similar but different.

Authors:  Rainer Wessely; Albert Schömig; Adnan Kastrati
Journal:  J Am Coll Cardiol       Date:  2006-01-26       Impact factor: 24.094

Review 8.  Vascular responses to drug eluting stents: importance of delayed healing.

Authors:  Aloke V Finn; Gaku Nakazawa; Michael Joner; Frank D Kolodgie; Erik K Mont; Herman K Gold; Renu Virmani
Journal:  Arterioscler Thromb Vasc Biol       Date:  2007-05-17       Impact factor: 8.311

9.  Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious?

Authors:  Renu Virmani; Giulio Guagliumi; Andrew Farb; Giuseppe Musumeci; Niccolo Grieco; Teresio Motta; Laurian Mihalcsik; Maurizio Tespili; Orazio Valsecchi; Frank D Kolodgie
Journal:  Circulation       Date:  2004-01-26       Impact factor: 29.690

10.  Comparative characterization of cellular and molecular anti-restenotic profiles of paclitaxel and sirolimus. Implications for local drug delivery.

Authors:  Rainer Wessely; Birgit Blaich; Rachida Siham Belaiba; Sabine Merl; Agnes Görlach; Adnan Kastrati; Albert Schömig
Journal:  Thromb Haemost       Date:  2007-06       Impact factor: 5.249

View more
  2 in total

1.  One-year clinical outcomes of different coronary drug eluting stents-Data from a prospective registry.

Authors:  B K S Sastry; Krishna Reddy Nallamalla; Nirmal Kumar; Deepti Kodati; Rajeev Menon
Journal:  Indian Heart J       Date:  2018-05-17

2.  Long term safety and efficacy of the Yukon Choice Flex sirolimus-eluting coronary stent-a real-world data from India.

Authors:  Basant Kumar; Sourabh Agstam; Jyothi Vijay; Akash Batta
Journal:  Indian Heart J       Date:  2021-09-10
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.