| Literature DB >> 24963476 |
Robert W Jordan1, Nicholas A Smith2, Adnan Saithna1, Andrew P Sprowson2, Pedro Foguet1.
Abstract
BACKGROUND: Identifying the microorganism in a prosthetic joint infection is the key to appropriately targeting antimicrobial treatment. Despite the availability of various techniques, no single test is considered the definitive gold standard. AIM: Our aim was to determine the sensitivity, specificity, and positive/negative predictive values for a variety of culture techniques.Entities:
Mesh:
Year: 2014 PMID: 24963476 PMCID: PMC4055545 DOI: 10.1155/2014/180416
Source DB: PubMed Journal: Biomed Res Int Impact factor: 3.411
New definition for periprosthetic joint infection: from the workgroup of the Musculoskeletal Infection Society [19].
| The presence of a major factor: |
| (1) Sinus tract communicating with the prosthesis; |
| (2) Pathogen isolated by culture from 2 or more separate tissue or fluid samples. |
| The presence of 4 out of the 6 minor factors: |
| (1) Elevated erythrocyte sedimentation rate and serum C-reactive protein concentration; |
| (2) Elevated synovial white blood cell count; |
| (3) Elevated synovial polymorphonuclear percentage; |
| (4) Presence of purulence in the affected joint; |
| (5) Isolation of a microorganism in one culture of periprosthetic tissue or fluid; |
| (6) Greater than 5 neutrophils per high power field. |
Number of patients having at least one sample analysed by each technique.
| Sampling technique | Infected cases | Noninfected cases |
|---|---|---|
| Blood culture vials | 20 (60.6) | 93 (51.6) |
| Sterile container | 23 (69.7) | 99 (53.2) |
| Tissue sample | 31 (93.9) | 160 (86.0) |
Sensitivity, specificity, and positive and negative predictive values.
| Sensitivity | Specificity | Positive predictive value | Negative predictive value | |
|---|---|---|---|---|
| Blood culture vials | 0.85 | 1.0 | 1.0 | 0.97 |
| Sterile container | 0.26 | 0.99 | 0.86 | 0.85 |
| Tissue sample | 0.32 | 0.99 | 0.88 | 0.84 |
Microorganisms isolated in infected cases.
| Positive standard culture | |
|---|---|
| Coagulase negative | 15 |
|
| 11 |
|
| 3 |
|
| 3 |
|
| 2 |
Sensitivity, specificity, and positive and negative predictive values for those cases in which all 3 investigations were performed (n = 34).
| Sensitivity | Specificity | Positive predictive value | Negative predictive value | |
|---|---|---|---|---|
| Blood culture vials | 0.58 | 1.0 | 1.0 | 0.71 |
| Sterile container | 0.47 | 1.0 | 1.0 | 0.61 |
| Tissue sample | 0.17 | 0.98 | 0.93 | 0.43 |
Indication for further revision surgery in the noninfected cohort.
| Indication | Number |
|---|---|
| Instability | 11 |
| Infection | 5 |
| Periprosthetic fracture | 2 |
| Aseptic loosening | 2 |