Literature DB >> 24960642

A non-invasive strategy for haemoglobin screening of blood donors.

Pasqualepaolo Pagliaro1, Annarita Belardinelli1, Viana Boko1, Petar Salamon1, Silvia Manfroi1, Pier Luigi Tazzari1.   

Abstract

INTRODUCTION: Assessing blood-donor haemoglobin (Hb) is a worldwide screening requirement against inappropriate donation. The pre-donation Hb (which should be at least 12.5 g/dL in women and 13.5 g/dL in men) is usually determined in capillary blood from a finger prick, using a spectrophotometer which reveals the absorbance of blood haemolysed in a microcuvette. New non-invasive methods of measuring Hb are now available.
MATERIALS AND METHODS: In the first semester of 3 consecutive years three different strategies were employed to screen donors for anaemia at the moment of donation. In 2011 all whole-blood donors underwent the finger-prick method using azide-methaemoglobin: the test's negative predictive value (NPV) was determined by comparison with the sub-threshold Hb values ascertained by haemocytometry of test-tube blood drawn at the start of the donation. In 2012 the donor evaluation was based on NBM 200 occlusion spectrophotometry. The same approach was kept in 2013, but a haemocytometry test was added on a pre-donation venous sample drawn from donors who, though fit to donate, had previous critical Hb values in their clinical records.
RESULTS: In 2011, the NPV (in 3,856 donors) was 86% for women and 95% for men; in 2012 (3,966 donors), the values were 85% and 95%, respectively, and in 2013 (3,995 donors) they were 91% and 97%, respectively. Fisher's test for contingency tables revealed no statistically significant differences between 2011 and 2012, but the 2013 results were a significant improvement. DISCUSSION: Measuring Hb by finger prick is not wholly satisfactory since, above all in women, the result of this screening may subsequently be belied by the haemocytometry finding of an unacceptable Hb value. Using a non-invasive method does not diminish the selective efficiency. In women, in particular, adding a haemocytometric test on a venous sample significantly improves donor selection and avoids the risk of inappropriate donation or blood-letting.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24960642      PMCID: PMC4212024          DOI: 10.2450/2014.0284-13

Source DB:  PubMed          Journal:  Blood Transfus        ISSN: 1723-2007            Impact factor:   3.443


  17 in total

1.  Hb screening of blood donors: how close is close enough?

Authors:  Ritchard G Cable
Journal:  Transfusion       Date:  2003-03       Impact factor: 3.157

2.  Accuracy of predonation Hct sampling affects donor safety, eligibility, and deferral rates.

Authors:  E M Wood; D M Kim; J P Miller
Journal:  Transfusion       Date:  2001-03       Impact factor: 3.157

3.  A comparative study of oxyhemoglobin and cyanmethemoglobin determinations by photometric and spectrophotometric methods.

Authors:  N J DUCHATEAU
Journal:  Am J Med Technol       Date:  1957 Jan-Feb

4.  The new noninvasive occlusion spectroscopy hemoglobin measurement method: a reliable and easy anemia screening test for blood donors.

Authors:  Márcio Pinto; Maria Lourdes Barjas-Castro; Simone Nascimento; Mônica Almeida Falconi; Roberto Zulli; Vagner Castro
Journal:  Transfusion       Date:  2012-07-15       Impact factor: 3.157

5.  Noninvasive methods for haemoglobin screening in prospective blood donors.

Authors:  A Belardinelli; M Benni; P L Tazzari; P Pagliaro
Journal:  Vox Sang       Date:  2013-04-19       Impact factor: 2.144

6.  Capillary versus venous haemoglobin determination in the assessment of healthy blood donors.

Authors:  A J Patel; R Wesley; S F Leitman; B J Bryant
Journal:  Vox Sang       Date:  2013-01-07       Impact factor: 2.144

7.  An azide-methemoglobin method for hemoglobin determination in blood.

Authors:  G Vanzetti
Journal:  J Lab Clin Med       Date:  1966-01

8.  Improved strategy for screening prospective blood donors for anaemia.

Authors:  F E Boulton; M J Nightingale; W Reynolds
Journal:  Transfus Med       Date:  1994-09       Impact factor: 2.019

9.  High prevalence of subclinical iron deficiency in whole blood donors not deferred for low hemoglobin.

Authors:  A Mireille Baart; Paulus A H van Noord; Yvonne Vergouwe; Karel G M Moons; Dorine W Swinkels; Erwin T Wiegerinck; Wim L A M de Kort; Femke Atsma
Journal:  Transfusion       Date:  2012-11-26       Impact factor: 3.157

10.  Etiology of anemia of blood donor candidates deferred by hematologic screening.

Authors:  Michel Alves da Silva; Renata Andréia Volpe de Souza; Aline Meneses Carlos; Sheila Soares; Helio Moraes-Souza; Gilberto de Araujo Pereira
Journal:  Rev Bras Hematol Hemoter       Date:  2012
View more
  2 in total

1.  Evaluation of capillary haemoglobin determination for anaemia screening in blood donation settings.

Authors:  Massimo Daves; Roberto Cemin; Elmar M Zagler; Alexandra Joos; Stefan Platzgummer; Rudolf Hueber; Giuseppe Lippi
Journal:  Blood Transfus       Date:  2016-01-19       Impact factor: 3.443

Review 2.  Techniques used for the screening of hemoglobin levels in blood donors: current insights and future directions.

Authors:  Rajendra Chaudhary; Anju Dubey; Atul Sonker
Journal:  J Blood Med       Date:  2017-07-03
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.