Literature DB >> 22803617

The new noninvasive occlusion spectroscopy hemoglobin measurement method: a reliable and easy anemia screening test for blood donors.

Márcio Pinto1, Maria Lourdes Barjas-Castro, Simone Nascimento, Mônica Almeida Falconi, Roberto Zulli, Vagner Castro.   

Abstract

BACKGROUND: The tests used for anemia screening in blood donors are based on fingerstick samples, leading to discomfort and complaints. The aim of this study was to analyze the feasibility of occlusion spectroscopy method in blood banks and to compare the method with fingerstick hemoglobinometer and hemoglobin (Hb) determination on an automatic blood analyzer. STUDY DESIGN AND METHODS: The study enrolled 205 consecutive volunteer blood donors. Samples were collected by fingerstick and venous punction to determine Hb level by a Hemocue Hb201+ (Hb-F) and automatic blood analyzer (Hb-V) and compare to the noninvasive Hb determination by occlusion spectroscopy using NBM200 system (Hb-NI). The percentage errors of Hb-F and Hb-NI of all donors as well as stratified by sex, weight, and age levels were compared to Hb-V as reference values using Wilcoxon signed rank test.
RESULTS: The results obtained with Hb-F showed significant errors (p<0.001) in the general group as well as when stratified by sex, weight, and age groups, above values obtained with Hb-V. Hb-NI showed significant errors only in females (p=0.026) and weight level of 61 to 70kg (p=0.034), below Hb-V values.
CONCLUSIONS: Hb-NI seems to be a good method in terms of precision and feasibility for anemia screening of blood donors as well as being much more comfortable for donors.
© 2012 American Association of Blood Banks.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22803617     DOI: 10.1111/j.1537-2995.2012.03784.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  7 in total

1.  Evaluation of various methods of point-of-care testing of haemoglobin concentration in blood donors.

Authors:  Abhay Singh; Anju Dubey; Atul Sonker; Rajendra Chaudhary
Journal:  Blood Transfus       Date:  2014-10-29       Impact factor: 3.443

2.  Detection of anaemia from retinal fundus images via deep learning.

Authors:  Yun Liu; Avinash V Varadarajan; Akinori Mitani; Abigail Huang; Subhashini Venugopalan; Greg S Corrado; Lily Peng; Dale R Webster; Naama Hammel
Journal:  Nat Biomed Eng       Date:  2019-12-23       Impact factor: 25.671

3.  Point of care hemoglobin testing in plateletpheresis donors: Noninvasive versus invasive methods.

Authors:  R S Mallhi; Amit Pawar; Neerja Kushwaha; Sudeep Kumar; Ujjwal Dimri
Journal:  Med J Armed Forces India       Date:  2016-08-11

4.  A non-invasive strategy for haemoglobin screening of blood donors.

Authors:  Pasqualepaolo Pagliaro; Annarita Belardinelli; Viana Boko; Petar Salamon; Silvia Manfroi; Pier Luigi Tazzari
Journal:  Blood Transfus       Date:  2014-06-05       Impact factor: 3.443

Review 5.  Emerging point-of-care technologies for anemia detection.

Authors:  Ran An; Yuning Huang; Yuncheng Man; Russell W Valentine; Erdem Kucukal; Utku Goreke; Zoe Sekyonda; Connie Piccone; Amma Owusu-Ansah; Sanjay Ahuja; Jane A Little; Umut A Gurkan
Journal:  Lab Chip       Date:  2021-05-18       Impact factor: 6.799

6.  An instantaneous low-cost point-of-care anemia detection device.

Authors:  Jaime Punter-Villagrasa; Joan Cid; Cristina Páez-Avilés; Ivón Rodríguez-Villarreal; Esteve Juanola-Feliu; Jordi Colomer-Farrarons; Pere Ll Miribel-Català
Journal:  Sensors (Basel)       Date:  2015-02-16       Impact factor: 3.576

Review 7.  Techniques used for the screening of hemoglobin levels in blood donors: current insights and future directions.

Authors:  Rajendra Chaudhary; Anju Dubey; Atul Sonker
Journal:  J Blood Med       Date:  2017-07-03
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.