Literature DB >> 24959450

Root Cause Analysis (RCA) of Prolonged Laboratory Turnaround Time in a Tertiary Care Set up.

Kalyan Khan1.   

Abstract

INTRODUCTION: Among the multitude of daily administrative problems which are faced by the modern hospitals today, prolonged Turnaround Time (TAT) of laboratory investigations is a crucial one, which affects patient care as well as patient satisfaction adversely. AIMS AND
OBJECTIVES: The specific objectives were to observe the TAT of common laboratory investigations, to identify cause of increased turnaround time and to formulate action plans to rectify increased TAT.
METHODOLOGY: An observational, RCA study was performed on 100 randomly selected patients. A separate group of 50 patients were assisted to get their investigations done and to reduce the time intervals without actively interfering with the steps. The results which were obtained were accepted as standards. Root cause analysis of the delays which were detected in TAT was done. Time intervals of TAT in the two groups were compared by 2 tailed t-tests done for equality of means. Result and Analysis: All time intervals were high in the study group and they were found to be statistically significant (p<0.05) within a 95% confidence interval of the difference. The maximum time which was needed in the control group was within the interval between the prescription of the investigation by the doctor and writing of the requisition by the Out-patient Department (OPD) staff. For the study population, it was the interval between the writing of the requisition by the OPD staff and the reaching of the patient at the central Laboratory. The standard deviation (27.665) and range (102) were also exceptionally high for this interval in the study group.
CONCLUSION: This study revealed that easy to implement administrative steps would help in reducing the TAT significantly and in improving the quality of services of the central laboratory. These include the setting up of sample collection counters at the outpatient department (OPD) and inpatient department (IPD), employment of minor methods like printing the directions for reaching the laboratory on the OPD ticket, the start of a single prick policy, declaring central laboratory as a separate department and integration of the administrative control under one authority.

Entities:  

Keywords:  Laboratory Turnaround Time; Pathology Investigations; Root Cause Analysis

Year:  2014        PMID: 24959450      PMCID: PMC4064846          DOI: 10.7860/JCDR/2014/7269.4255

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  13 in total

1.  Use of computer terminals on wards to access emergency test results: a retrospective audit.

Authors:  E S Kilpatrick; S Holding
Journal:  BMJ       Date:  2001-05-05

Review 2.  Effects of computerized clinical decision support systems on practitioner performance and patient outcomes: a systematic review.

Authors:  Amit X Garg; Neill K J Adhikari; Heather McDonald; M Patricia Rosas-Arellano; P J Devereaux; Joseph Beyene; Justina Sam; R Brian Haynes
Journal:  JAMA       Date:  2005-03-09       Impact factor: 56.272

3.  Demand-driven evolution of IT systems in healthcare--a case study for improving interdisciplinary processes.

Authors:  R Lenz; F Buessecker; H Herlofsen; F Hinrichs; T Zeiler; K A Kuhn
Journal:  Methods Inf Med       Date:  2005       Impact factor: 2.176

4.  The doctor will see you shortly. The ethical significance of time for the patient-physician relationship.

Authors:  Clarence H Braddock; Lois Snyder
Journal:  J Gen Intern Med       Date:  2005-11       Impact factor: 5.128

5.  Techniques for root cause analysis.

Authors:  P M Williams
Journal:  Proc (Bayl Univ Med Cent)       Date:  2001-04

6.  The attributes of medical event-reporting systems: experience with a prototype medical event-reporting system for transfusion medicine.

Authors:  J B Battles; H S Kaplan; T W Van der Schaaf; C E Shea
Journal:  Arch Pathol Lab Med       Date:  1998-03       Impact factor: 5.534

7.  The elimination of turnaround time in routine ECG processing.

Authors:  R Tell; I Hoffman
Journal:  J Electrocardiol       Date:  1971       Impact factor: 1.438

8.  Computer-generated management tools for the clinical pathology laboratory. II. Computer-generated graphic work flow.

Authors:  D M Bloch
Journal:  J Med Syst       Date:  1982-06       Impact factor: 4.460

9.  "I wish I had seen this test result earlier!": Dissatisfaction with test result management systems in primary care.

Authors:  Eric G Poon; Tejal K Gandhi; Thomas D Sequist; Harvey J Murff; Andrew S Karson; David W Bates
Journal:  Arch Intern Med       Date:  2004-11-08

10.  Effect of computer-based alerts on the treatment and outcomes of hospitalized patients.

Authors:  D M Rind; C Safran; R S Phillips; Q Wang; D R Calkins; T L Delbanco; H L Bleich; W V Slack
Journal:  Arch Intern Med       Date:  1994-07-11
View more
  2 in total

1.  Timely delivery of laboratory efficiency information, Part II: Assessing the impact of a turn-around time dashboard at a high-volume laboratory.

Authors:  Naseem Cassim; Lindi M Coetzee; Manfred E E Tepper; Louella Perelson; Deborah K Glencross
Journal:  Afr J Lab Med       Date:  2020-04-23

2.  Therapeutic turnaround times for common laboratory tests in a tertiary hospital in Kenya.

Authors:  Thomas Mwogi; Tim Mercer; Dan N Tina Tran; Ronald Tonui; Thorkild Tylleskar; Martin C Were
Journal:  PLoS One       Date:  2020-04-08       Impact factor: 3.240