| Literature DB >> 24959071 |
Grażyna Lisowska1, Grzegorz Namyslowski1, Boguslawa Orecka1, Maciej Misiolek1.
Abstract
BACKGROUND: There is still controversy regarding the influence of aging on medial olivocochlear (MOC) system function. The main objective of this study is to measure age-related changes of MOC system function in people with normal hearing thresholds.Entities:
Keywords: MOC effect; MOC inhibition; age; contralateral suppression; efferent suppression; medial olivocochlear system; otoacoustic emissions
Mesh:
Year: 2014 PMID: 24959071 PMCID: PMC4061140 DOI: 10.2147/CIA.S61934
Source DB: PubMed Journal: Clin Interv Aging ISSN: 1176-9092 Impact factor: 4.458
Characteristics of the tested subgroups
| Group | N (ears) | Mean age (years) | Standard deviation |
|---|---|---|---|
| All subjects | 292 | 28.6 | 11.5 |
| Subjects aged 10–25 years | 140 | 19.8 | 4.6 |
| Subjects aged 26–40 years | 100 | 31.2 | 4.3 |
| Subjects aged 41–60 years | 52 | 48.2 | 5.9 |
Figure 1Schematic presentation of the protocol for medial olivocochlear system effect analysis.
Abbreviations: OAE, otoacoustic emissions; CAS, contralateral acoustic stimulation; BBN, broadband noise; SL, sensation level.
Number of tests used for the final analysis of overall click-evoked otoacoustic emissions response and for the half-octave bandwidth centered at 1, 2, 3, 4, and 5 kHz frequencies
| Click-evoked otoacoustic emissions | Number of analyzed ears
| |||||
|---|---|---|---|---|---|---|
| Overall click-evoked otoacoustic emissions response | 1,000 Hz | 2,000 Hz | 3,000 Hz | 4,000 Hz | 5,000 Hz | |
| All subjects | 292 | 284 | 292 | 265 | 256 | 116 |
| Subjects aged 10–25 years | 140 | 135 | 140 | 129 | 124 | 44 |
| Subjects aged 26–40 years | 100 | 100 | 100 | 90 | 94 | 49 |
| Subjects aged 41–60 years | 52 | 49 | 52 | 46 | 38 | 23 |
Number of tests used for the final analysis of f1 distortion product otoacoustic emissions response
| Distortion product otoacoustic emissions | Number of analyzed ears
| ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 977 Hz | 1,160 Hz | 1,379 Hz | 1,636 Hz | 1,953 Hz | 2,319 Hz | 2,759 Hz | 3,284 Hz | 3,894 Hz | 4,639 Hz | 5,164 Hz | |
| All subjects | 220 | 224 | 227 | 225 | 216 | 226 | 223 | 223 | 216 | 210 | 191 |
| Subjects aged 10–25 years | 77 | 80 | 80 | 79 | 75 | 79 | 80 | 80 | 78 | 75 | 75 |
| Subjects aged 26–40 years | 89 | 91 | 92 | 92 | 88 | 91 | 90 | 93 | 90 | 91 | 81 |
| Subjects aged 41–60 years | 54 | 53 | 55 | 54 | 53 | 56 | 53 | 50 | 48 | 44 | 35 |
Comparison of pure-tone audiometry (PTA) in three age groups
| Group | Pure-tone audiometry 1, dB hearing level | Pure-tone audiometry 2, dB hearing level | Pure-tone audiometry 3, dB hearing level | Broadband noise, dB sound pressure level |
|---|---|---|---|---|
| All subjects | 7.3±4.1 | 6.3±4.6 | 7.7±4.7 | 14.6±3.5 |
| Subjects aged 10–25 years | 5.8±3.8 | 3.2±3.9 | 4.1±3.7 | 14.1±3.2 |
| Subjects aged 26–40 years | 7.3±3.9 | 6.3±4.6 | 7.05±5.1 | 14.6±3.5 |
| Subjects aged 41–60 years | 8.9±4.5 | 9.5±5.4 | 11.9±5.3 | 15.2±3.9 |
Notes: Pure-tone audiometry 1 (mean threshold at 0.25, 0.5, 1 kHz); pure-tone audiometry 2 (mean threshold at 1, 2, 4 kHz); pure-tone audiometry 3 (mean threshold at 1, 2, 4, 6 kHz). According to the predefined qualification criteria, all subjects had a bilateral hearing threshold from 0.25 to 4 kHz, not exceeding 20 dB hearing level at each individual frequency. Significant results for the comparisons among subgroups are marked
P<0.05 (group 10–25 versus 41–60 years)
P<0.01 (group 10–25 versus 41–60 years).
Comparison of click-evoked otoacoustic emissions levels for overall response and particular click-evoked otoacoustic emissions frequencies (mean ± standard deviation) in three age groups
| Click-evoked otoacoustic emissions | 10–25 years | 26–40 years | 41–60 years | |||
|---|---|---|---|---|---|---|
| Overall response | 12.3±4.1 | 12.6±4.2 | 10.4±3.3 | 0.64 | ||
| 1,000 Hz | 10.2±5.8 | 9.9±5.7 | 7.4±3.9 | 0.66 | ||
| 2,000 Hz | 10.9±5.5 | 11.1±4.7 | 9.2±4.6 | 0.72 | ||
| 3,000 Hz | 7.6±5.8 | 7.6±5.2 | 5.3±4.3 | 0.98 | ||
| 4,000 Hz | 6.1±5.7 | 4.9±5.4 | 3.2±4.2 | 0.10 | 0.07 | |
| 5,000 Hz | 4.0±6.7 | 1.3±3.4 | 3.3±5.0 | 0.56 | 0.11 |
Notes: The P-values refer to comparisons between the age subgroups; significant differences are presented in bold.
Figure 2Comparison of click-evoked otoacoustic emissions (CEOAE) levels for overall response and for particular click-evoked otoacoustic emissions frequencies (mean ± confidence interval) in three age groups.
Abbreviation: RES, overall response.
Comparison of click-evoked otoacoustic emissions levels without and with contralateral acoustic stimulation for overall response and particular click-evoked otoacoustic emissions frequencies (mean ± standard deviation) in three age groups
| Click-evoked otoacoustic emissions | Click-evoked otoacoustic emissions level without contralateral acoustic stimulation | Click-evoked otoacoustic emissions level with contralateral acoustic stimulation | Adj |
|---|---|---|---|
| 10–25 years | |||
| Overall response | 12.3±4.1 | 10.2±4.1 | |
| 1,000 Hz | 10.3±5.8 | 7.6±5.6 | |
| 2,000 Hz | 10.9±5.5 | 8.8±5.7 | |
| 3,000 Hz | 7.8±5.8 | 6.1±5.6 | |
| 4,000 Hz | 6.1±5.7 | 5.3±5.7 | |
| 5,000 Hz | 4.4±6.5 | 3.6±6.0 | 0.50 |
| 26–40 years | |||
| Overall response | 12.7±4.1 | 10.6±4.3 | |
| 1,000 Hz | 9.9±5.7 | 7.3±5.9 | |
| 2,000 Hz | 11.1±4.7 | 9.1±4.9 | |
| 3,000 Hz | 7.9±5.0 | 6.5±4.9 | |
| 4,000 Hz | 5.0±5.4 | 3.9±5.5 | |
| 5,000 Hz | 1.7±3.3 | 1.0±3.4 | 1.00 |
| 41–60 years | |||
| Overall response | 10.4±3.3 | 8.3±3.8 | |
| 1,000 Hz | 7.4±3.9 | 4.4±4.3 | |
| 2,000 Hz | 9.2±4.6 | 8.5±5.2 | 0.56 |
| 3,000 Hz | 5.3±4.3 | 4.3±4.4 | 0.39 |
| 4,000 Hz | 3.2±4.2 | 2.6±4.9 | 1.00 |
| 5,000 Hz | 3.8±4.9 | 3.5±5.1 | 1.00 |
Note: Significant differences are presented in bold.
Abbreviation: Adj P, Bonferroni adjusted P-values.
Figure 3The medial olivocochlear (MOC) system effect for overall response and for particular click-evoked otoacoustic emissions frequencies (mean ± 95% confidence interval) in three age groups.
Notes: Significant differences in the medial olivocochlear system effect: *P<0.01 (group 10–25 years versus 41–60 years); #P<0.01 (group 26–40 years versus 41–60 years).
Abbreviation: RES, overall response.
Comparison of distortion product otoacoustic emissions levels for particular distortion product otoacoustic emissions f1 frequencies (mean ± standard deviation) in three age groups
| Distortion product otoacoustic emissions f1 | 10–25 years | 26–40 years | 41–60 years | |||
|---|---|---|---|---|---|---|
| 977 Hz | 12.7±5.3 | 10.7±5.6 | 10.0±5.0 | 0.55 | ||
| 1,160 Hz | 12.8±7.0 | 11.9±5.2 | 11.1±6.2 | 0.34 | 0.10 | 0.39 |
| 1,379 Hz | 12.8±5.4 | 10.8±5.3 | 9.1±4.7 | 0.09 | ||
| 1,636 Hz | 11.0±5.5 | 8.6±5.2 | 7.1±4.2 | 0.16 | ||
| 1,953 Hz | 10.0±5.5 | 7.8±5.6 | 5.1±4.5 | |||
| 2,319 Hz | 9.0±5.2 | 6.7±5.9 | 4.3±5.9 | |||
| 2,759 Hz | 10.3±5.5 | 7.5±5.7 | 2.5±4.6 | |||
| 3,284 Hz | 11.0±5.9 | 8.8±5.7 | 4.0±5.6 | |||
| 3,894 Hz | 12.3±6.7 | 10.0±6.5 | 5.4±6.7 | |||
| 4,639 Hz | 11.2±7.5 | 9.0±7.1 | 3.2±6.9 | |||
| 5,164 Hz | 7.4±8.0 | 5.4±8.4 | −0.8±8.0 |
Notes: The P-values refer to comparisons between the age subgroups; significant differences are presented in bold.
Figure 4Comparison of distortion product otoacoustic emissions (DPOAE) levels for particular distortion product otoacoustic emissions f1 frequencies (mean ± 95% confidence interval) in three age groups.
Comparison of distortion product otoacoustic emissions levels without and with contralateral acoustic stimulation for particular distortion product otoacoustic emissions f1 frequencies (mean ± standard deviation) in three age groups
| Distortion product otoacoustic emissions f1 | Distortion product otoacoustic emissions level without contralateral acoustic stimulation | Distortion product otoacoustic emissions level with contralateral acoustic stimulation | Adj |
|---|---|---|---|
| 10–25 years | |||
| 977 Hz | 12.7±5.3 | 11.3±5.1 | |
| 1,160 Hz | 12.8±7.0 | 11.8±6.4 | |
| 1,379 Hz | 12.8±5.4 | 11.7±5.2 | |
| 1,636 Hz | 11.0±5.5 | 10.1±5.3 | |
| 1,953 Hz | 10.0±5.5 | 8.9±5.6 | |
| 2,319 Hz | 9.0±5.2 | 8.4±4.8 | 0.18 |
| 2,759 Hz | 10.3±5.5 | 10.1±5.5 | 1.00 |
| 3,284 Hz | 11.0±5.9 | 10.7±5.9 | 1.00 |
| 3,894 Hz | 12.5±6.5 | 12.2±6.4 | 1.00 |
| 4,639 Hz | 11.6±7.0 | 11.0±7.1 | |
| 5,164 Hz | 7.6±7.9 | 7.3±7.8 | 1.00 |
| 26–40 years | |||
| 977 Hz | 10.7±5.6 | 8.5±6.1 | |
| 1,160 Hz | 11.9±5.2 | 10.6±5.3 | |
| 1,379 Hz | 10.9±5.1 | 9.6±5.3 | |
| 1,636 Hz | 8.6±5.2 | 7.7±5.4 | |
| 1,953 Hz | 7.8±5.6 | 6.7±5.5 | |
| 2,319 Hz | 6.7±5.9 | 5.9±5.7 | |
| 2,759 Hz | 7.5±5.7 | 6.9±5.5 | |
| 3,284 Hz | 8.8±5.7 | 8.2±6.0 | |
| 3,894 Hz | 10.0±6.5 | 9.3±6.5 | |
| 4,639 Hz | 9.2±7.0 | 8.3±7.4 | |
| 5,164 Hz | 5.9±8.1 | 5.2±8.8 | 0.08 |
| 41–60 years | |||
| 977 Hz | 10.0±5.0 | 8.7±5.0 | |
| 1,160 Hz | 11.1±6.2 | 9.9±6.4 | |
| 1,379 Hz | 9.1±4.7 | 8.3±4.4 | 0.07 |
| 1,636 Hz | 7.1±4.2 | 6.3±4.3 | |
| 1,953 Hz | 5.1±4.5 | 4.2±4.4 | |
| 2,319 Hz | 4.3±5.9 | 3.5±5.9 | 0.09 |
| 2,759 Hz | 2.5±4.6 | 2.3±4.5 | 1.00 |
| 3,284 Hz | 4.0±5.6 | 3.6±5.8 | 1.00 |
| 3,894 Hz | 5.4±6.7 | 5.0±7.0 | 1.00 |
| 4,639 Hz | 3.2±6.9 | 3.4±7.1 | 1.00 |
| 5,164 Hz | −0.8±8.0 | −0.8±8.2 | 1.00 |
Note: Significant differences are presented in bold.
Abbreviation: Adj P, Bonferroni adjusted P-values.
Figure 5The medial olivocochlear (MOC) system effect for particular distortion product otoacoustic emissions f1 frequencies (mean ± confidence interval) in three age groups.
Notes: Significant differences in the medial olivocochlear system effect: @P<0.01 (group 10–25 years versus 26–40 years); #P<0.01 (group 26–40 years versus 41–60 years).